Product Purity Analyzer. The producer shall be provided with a gaseous analyzer that is capable of measuring the nitrogen gas streams. The analyzer shall be of paramagnetic type (Servomex Model 1800) accurate to within plus or minus 0.1 percent for measuring nitrogen purity. When nitrogen purity drops below 99.5 percent, the analyzer shall send a signal to dispose of or recycle the impure nitrogen. The delivery of nitrogen to storage when within purity specifications shall be automatic. Analyzer calibration equipment suitable for ship operator use and stowage shall be provided with the nitrogen producer, and shall include: calibration gas, cylinders, associated hoses, fittings, regulators, etc. 3.19 Programmable Logic Controller (PLC): A PLC or similar device programmed for complete, safe and reliable operation shall be contained within the oxygen generation and storage system. The PLC shall automatically sense control system parameters (temperature, pressure, bulk purity, etc,) and energize the system, produce and store nitrogen product in accordance with the capacity and purity requirements of this specification. The PLC shall be designed so that installation, operation, inspection, maintenance and adjustments can be accomplished without causing injury or damage to equipment. It shall be designed so that one failure will not cause or produce an unsafe condition nor shall it cause a ripple effect. The PLC’s electrical system shall provide built-in safety features comprised of both hardware and software to guarantee safe system operation. The controller shall incorporate safety features for out of tolerance electrical voltages, and current. The PLC shall automatically detect out-of-specification conditions, record conditions, and secure the plant safely, at which time personnel actions would reestablish proper parameters. All software executables (PLC and PC), PLC ladder logic and PC source code; software tools (and/or licenses if applicable) and other software support information shall be provided with the producer. If PLC is password protected those passwords shall be supplied with the producer. (CDRL A024, A025, A029)
AutoNDA by SimpleDocs
Product Purity Analyzer. The analyzer shall meet the requirements of paragraph 3.18 and all shock, vibration and EMI requirements specified herein. The requirements of paragraph 3.18 shall be demonstrated in conjunction with paragraph 4.6.6.

Related to Product Purity Analyzer

  • API If the Software offers integration capabilities via an API, your use of the API may be subject to additional costs or Sage specific policies and terms and conditions (which shall prevail in relation to your use of the API). You may not access or use the API in any way that could cause damage to us or the Software, or in contravention of any applicable laws. We reserve the right in our sole discretion, to: (i) update any API from time to time; (ii) place limitations around your use of any API; and (iii) deny you access to any API in the event of misuse by you or to otherwise protect our legitimate interests.

  • Product ACCEPTANCE Unless otherwise provided by mutual agreement of the Authorized User and the Contractor, Authorized User(s) shall have thirty (30) days from the date of delivery to accept hardware products and sixty (60) days from the date of delivery to accept all other Product. Where the Contractor is responsible for installation, acceptance shall be from completion of installation. Failure to provide notice of acceptance or rejection or a deficiency statement to the Contractor by the end of the period provided for under this clause constitutes acceptance by the Authorized User(s) as of the expiration of that period. The License Term shall be extended by the time periods allowed for trial use, testing and acceptance unless the Commissioner or Authorized User agrees to accept the Product at completion of trial use. Unless otherwise provided by mutual agreement of the Authorized User and the Contractor, Authorized User shall have the option to run testing on the Product prior to acceptance, such tests and data sets to be specified by User. Where using its own data or tests, Authorized User must have the tests or representative set of data available upon delivery. This demonstration will take the form of a documented installation test, capable of observation by the Authorized User, and shall be made part of the Contractor’s standard documentation. The test data shall remain accessible to the Authorized User after completion of the test. In the event that the documented installation test cannot be completed successfully within the specified acceptance period, and the Contractor or Product is responsible for the delay, Authorized User shall have the option to cancel the order in whole or in part, or to extend the testing period for an additional thirty (30) day increment. Authorized User shall notify Contractor of acceptance upon successful completion of the documented installation test. Such cancellation shall not give rise to any cause of action against the Authorized User for damages, loss of profits, expenses, or other remuneration of any kind. If the Authorized User elects to provide a deficiency statement specifying how the Product fails to meet the specifications within the testing period, Contractor shall have thirty (30) days to correct the deficiency, and the Authorized User shall have an additional sixty (60) days to evaluate the Product as provided herein. If the Product does not meet the specifications at the end of the extended testing period, Authorized User, upon prior written notice to Contractor, may then reject the Product and return all defective Product to Contractor, and Contractor shall refund any monies paid by the Authorized User to Contractor therefor. Costs and liabilities associated with a failure of the Product to perform in accordance with the functionality tests or product specifications during the acceptance period shall be borne fully by Contractor to the extent that said costs or liabilities shall not have been caused by negligent or willful acts or omissions of the Authorized User’s agents or employees. Said costs shall be limited to the amounts set forth in the Limitation of Liability Clause for any liability for costs incurred at the direction or recommendation of Contractor.

  • ODUF Packing Specifications 6.3.1 The data will be packed using ATIS EMI records. A pack will contain a minimum of one (1) message record or a maximum of ninety-nine thousand nine hundred and ninety-nine (99,999) message records plus a pack header record and a pack trailer record. One transmission can contain a maximum of ninety-nine (99) packs and a minimum of one (1) pack.

  • EODUF Packing Specifications 7.3.1 The data will be packed using ATIS EMI records. A pack will contain a minimum of one (1) message record or a maximum of ninety-nine thousand nine hundred and ninety-nine (99,999) message records plus a pack header record and a pack trailer record. One transmission can contain a maximum of ninety-nine (99) packs and a minimum of one (1) pack.

  • RE-WEIGHING PRODUCT Deliveries are subject to re- weighing at the point of destination by the Authorized User. If shrinkage occurs which exceeds that normally allowable in the trade, the Authorized User shall have the option to require delivery of the difference in quantity or to reduce the payment accordingly. Such option shall be exercised in writing by the Authorized User.

  • Biological Samples If so specified in the Protocol, Institution and Principal Investigator may collect and provide to Sponsor or its designee Biological Samples (“Biological Samples”). 12.2.

  • Software Components At any time during the contract period of performance, the Government may require the Contractor to remedy any failure of the software to comply with the requirements of this contract. Support shall consist of correction of errors, provision of modifications, improvements, and other products the original manufacturer makes available to the Government without charge. The Government shall also be provided full documentation of changes and/or modifications to the software provided to meet the Government's requirements.

  • Product Labeling The labeling of all Licensed Products sold or offered for sale under this Agreement shall expressly state that the Licensed Product is manufactured under a license from the Medicines Patent Pool.

  • On-Product Warnings The Settling Entity shall affix a warning to the label or otherwise directly on each unit of the Product provided through in-store retail outlets in California or sold online to consumers in California either directly or through its customers. For the purpose of this Settlement Agreement, “label” means a display of written, printed or graphic material that is printed on or affixed to a Product or its immediate container. The entire warning shall appear in a type size of at least 6-point type and no smaller than the largest type size used for other consumer information on the product. The warning language shall consist of either the Warning, or the Short-Form Warning described above in subsection 2.3(a) or (b), respectively, and be consistent with 2.3(c) above if it applies.

  • Product Recalls The Company is not aware of any pattern or series of claims against the Company or any of its subsidiaries which reasonably could be expected to result in a generalized product recall relating to products sold by the Company or any of its subsidiaries, regardless of whether such product recall is formal, informal, voluntary or involuntary.

Time is Money Join Law Insider Premium to draft better contracts faster.