Real-Time Operations (RTO Sample Clauses

Real-Time Operations (RTO. The PA does not propose changing any of the existing real-time operational processes currently in place for CVP/SWP operations. However, an additional RTO process would be implemented under the PA when the proposed north Delta diversion becomes operational. To complement the existing RTO process, DWR and Reclamation can convene a separate real time operations coordination team (RTOCT) that includes representatives of USFWS, NMFS, CDFW, DWR and Reclamation. DWR and Reclamation also will designate one representative of the SWP contractors and one representative of the CVP contractors as participants on the coordination team in an advisory capacity. This RTOCT effort will assist DWR and Reclamation in fulfilling their responsibility to inform the SWP and CVP contractor participants regarding available information and real-time decisions. This may result in recommendations being made through the Delta Conditions Team. Decision-making will still happen as it currently does under the USFWS 2008 and NMFS 2009 BiOps, as outlined in section 3.3.3 of the BA. For the PA, RTO are expected to be needed during at least some part of the year at the north and south Delta diversions and the HOR gate. Operational adjustments will be consistent with the criteria, and within any ranges, established in the PA. Any modifications to the criteria and/or ranges set out in the operating criteria will occur through the adaptive management program, and the effects of any such modifications will be analyzed by Reclamation and DWR, in consultation with NMFS and USFWS, to determine if Reclamation should reinitiate consultation prior to implementation.
AutoNDA by SimpleDocs

Related to Real-Time Operations (RTO

  • PREVAILING WAGE RATES - PUBLIC WORKS AND BUILDING SERVICES CONTRACTS If any portion of work being Bid is subject to the prevailing wage rate provisions of the Labor Law, the following shall apply:

  • Commercial Operation Date 6.4.1 The SPV shall ensure that the Project Commercial Operation Date is achieved on or prior to the Scheduled Commercial Operation Date. The SPV shall provide a written notice to MSEDCL at least 30 (thirty) days in advance intimating MSEDCL of the proposed date on which the Commercial Operation Date of a Unit or the Project is proposed to be achieved. 6.4.2 If the Commercial Operation Date for the Units having a capacity equivalent to at least 75% (seventy five percent) of the Contracted Capacity is achieved before the Scheduled Commercial Operation Date, then all Units in respect of which the Commercial Operation Date has been achieved prior to the Scheduled Commercial Operation Date would be eligible for incentives as follows: (a) the Unit(s) injecting energy at 11 kV /22 kV shall be given an incentive of Rs. 0.25/ kWh; and (b) the Unit(s) injecting energy at 33 kV shall be given an incentive of Rs. 0.15/ kWh, for the power sold to MSEDCL for the first 3 (three) years from the Commercial Operation Date. To receive such incentives from MSAPL, which shall be over and above the Tariff, the SPV shall follow the process agreed to by the SPV under the Implementation Agreement. 6.4.3 It is hereby clarified that the aforementioned incentive shall not be available: (i) in respect of any Unit if the Commercial Operation Date for such Unit has not been achieved prior to the Scheduled Commercial Operation Date; and (ii) if the aggregate capacity of the Units for which the Commercial Operation Date has been achieved prior to Scheduled Commercial Operation Date is less than 75% (seventy five percent) of the Contracted Capacity. 6.4.4 In the event that Commercial Operation Date for any of the Units is achieved after the Scheduled Commercial Operation Date, the SPV shall be liable to pay Liquidated Damages as per the provisions set out below. 6.4.5 Without prejudice to any other rights of MSEDCL under this PPA, in case one or more Units of the SPV are unable to achieve Commercial Operation Date within a period of 2 (two) months from the Scheduled Commercial Operation Date, the capacity of such Units shall be annulled, and the Contracted Capacity shall be reduced to that extent. For Illustration: The Project has a Contracted Capacity of 100 MW and comprises of 10 Units of 10 MW each. If at the end of the aforementioned period of 14 (fourteen) months from the Effective Date, the SPV has achieved Commissioning for only 8 out of 10 Units, then the Contracted Capacity of the Project will stand reduced for the capacity of the 2 Units which have not been Commissioned, i.e. the Contracted Capacity will be 80 (100 (original Contracted Capacity)) – 10 (capacity of each Unit)*2 (number of Units not Commissioned).

  • Safe Operations Notwithstanding any other provision of this Agreement, an NTO may take, or cause to be taken, such action with respect to the operation of its facilities as it deems necessary to maintain Safe Operations. To ensure Safe Operations, the local operating rules of the ITO(s) shall govern the connection and disconnection of generation with NTO transmission facilities. Safe Operations include the application and enforcement of rules, procedures and protocols that are intended to ensure the safety of personnel operating or performing work or tests on transmission facilities.

  • Service Commencement Date The date the Transmission Provider begins to provide service pursuant to the terms of an executed Service Agreement, or the date the Transmission Provider begins to provide service in accordance with Section 15.3 or Section 29.1 under the Tariff.

  • Sunday Work Employees required to work overtime on Sundays shall be paid for a minimum of three hours work at double time. The double time is to be paid until the employee is relieved from duty.

  • Lease Commencement Date The earlier to occur of (i) the date upon which Tenant first commences to conduct business in the Premises, and (ii) the later to occur of (A) November 1, 2018 and (B) the date upon which the Premises are Ready for Occupancy (as that term is defined in Section 5.1 of the Tenant Work Letter attached hereto as Exhibit B (the “Tenant Work Letter”)).

  • Operations Fire An “Operations Fire” is a fire caused by Purchaser’s Operations other than a Neg- ligent Fire.

  • Industrial Accident and Illness Leave For accidents or illnesses that are job- incurred, unit members shall be provided leave benefits under the following provisions: 12.6.1 Allowable leave shall be sixty (60) days during which the colleges of the District are required to be in session or when the unit member would otherwise have been performing work for the District in any one fiscal year for the same accident. 12.6.2 Allowable leave shall not be accumulated from year to year. 12.6.3 Industrial accident or illness leave shall commence on the first (1st) day of absence. 12.6.4 When a faculty member is absent from his/her duties on account of an industrial accident or illness, he/she shall be paid such portion of the salary due him/her for any month in which the absence occurs as, when added to his/her temporary disability indemnity under Division 4 or Division 4.5 (commencing with Section 6100) of the Labor Code, will result in a payment to him/her of not more than his/her full salary. The phrase, "full salary," as utilized in this section, shall be computed so that it shall not be less than the unit member's "average weekly earnings" as that phrase is utilized in Section 4453 of the Labor Code. For purposes of this section, however, the maximum and minimum average weekly earnings set forth in Section 4453 of the Labor Code shall otherwise not be deemed applicable. 12.6.5 Industrial accident or illness leave shall be reduced by one (1) day for each day of authorized absence regardless of a temporary disability indemnity award. 12.6.6 When an industrial accident or illness leave overlaps into the next fiscal year, the unit member shall be entitled to only the amount of unused industrial accident or illness leave due him/her for the same illness or injury. 12.6.7 Upon termination of the industrial accident or illness leave, the unit member shall be entitled to the benefits provided in Education Code Sections 87780, 87781 and 87786, and for the purposes of each of these sections his/her absence shall be deemed to have commenced on the date of termination for the industrial accident or illness leave, provided that if the unit member continues to receive temporary dis- ability indemnity, he/she may elect to take as much of his/her accumulated sick leave which, when added to his/her temporary disability indemnity, will result in a payment to him/her of not more than his/her full salary. 12.6.8 During any paid leave of absence, the unit member may endorse to the District the temporary disability indemnity checks received on account of his/her industrial accident or illness. The District, in turn, shall issue the unit member appropriate salary warrants for payment of the unit member's salary, and shall deduct normal retirement, other authorized contributions, and the temporary disability indemnity, if any, actually paid to, and retained by, the employee for periods covered by such salary warrants. 12.6.9 Any unit member receiving benefits as a result of this section shall, during periods of injury or illness, remain within the State of California, unless the Governing Board authorizes travel outside the state. 12.6.10 When all available leaves of absence have been exhausted and the unit member is not medically able to return to all the duties of his/her prior assignment, the District shall provide first (1st) priority in assigning such a person into classes where his/her disability, in the discretion of the District, does not hinder the performance of the duties required of him/her if he/she is otherwise qualified. With mutual agreement with the unit member, the District may also assign an employee into a position that can reasonably accommodate his/her performance of duties required by the position, despite his/her disability, prior to the exhaustion of leave of absence.

  • Commercial Operation (i) On or before December 31, 2021, Interconnection Customer must demonstrate commercial operation of all generating units. Demonstrating commercial operation includes achieving Initial Operation in accordance with Section 1.4 of Appendix 2 to this ISA and making commercial sales or use of energy, as well as, if applicable, obtaining capacity qualification in accordance with the requirements of the Reliability Assurance Agreement Among Load Serving Entities in the PJM Region.

  • Working Day Working Day means a day other than a Saturday, Sunday, or a holiday which is observed by the construction industry in the area of the Place of the Work.

Draft better contracts in just 5 minutes Get the weekly Law Insider newsletter packed with expert videos, webinars, ebooks, and more!