SAMPLING OF FUEL OIL Sample Clauses

SAMPLING OF FUEL OIL. Fuel oil delivered shall be subject to sampling and testing at the discretion of the purchasing Agency and/or OGS NYS Procurement. The samples shall be collected in accordance with ASTM D4057 (or most recent version) [IP #MPMS (Chapter 8.1)], or latest revision thereof. The usual method of sampling is a three-way bottle/container sampling taken at an upper, middle, and a lower sample point from the delivery vehicle. The sample container is a normally closed stopper type and operator opens it at each point to obtain a proportional amount of the sample. Agencies are strongly encouraged to maintain samples of all fuel oil deliveries for a period of time necessary to ensure that the fuel oil is in compliance with Contract specifications. Prior to the initial delivery, the Contractor should verify water and sediment levels in storage tanks. These levels shall be reported in writing for any tanks which require attention. Product samples taken at the Agency’s dispensing pump shall be considered representative of a disputed fuel oil delivery, when the Contractor has delivered one or more consecutive loads of fuel oil to the tank’s content which is in dispute. Additionally, when the purchasing Agency’s documentation indicates that previously delivered fuel oil is less than five percent of the tank’s fuel oil volume following any disputed delivery, and the previously delivered fuel oil performed and/or tested satisfactorily, then a sample taken from the pump may be considered representative of the fuel oil delivered.
AutoNDA by SimpleDocs

Related to SAMPLING OF FUEL OIL

  • Testing of Metering Equipment Connecting Transmission Owner shall inspect and test all of its Metering Equipment upon installation and at least once every two (2) years thereafter. If requested to do so by NYISO or Developer, Connecting Transmission Owner shall, at Developer’s expense, inspect or test Metering Equipment more frequently than every two (2) years. Connecting Transmission Owner shall give reasonable notice of the time when any inspection or test shall take place, and Developer and NYISO may have representatives present at the test or inspection. If at any time Metering Equipment is found to be inaccurate or defective, it shall be adjusted, repaired or replaced at Developer’s expense, in order to provide accurate metering, unless the inaccuracy or defect is due to Connecting Transmission Owner’s failure to maintain, then Connecting Transmission Owner shall pay. If Metering Equipment fails to register, or if the measurement made by Metering Equipment during a test varies by more than two percent from the measurement made by the standard meter used in the test, Connecting Transmission Owner shall adjust the measurements by correcting all measurements for the period during which Metering Equipment was in error by using Developer’s check meters, if installed. If no such check meters are installed or if the period cannot be reasonably ascertained, the adjustment shall be for the period immediately preceding the test of the Metering Equipment equal to one-half the time from the date of the last previous test of the Metering Equipment. The NYISO shall reserve the right to review all associated metering equipment installation on the Developer’s or Connecting Transmission Owner’s property at any time.

  • Sampling The Licensee agrees that the Composition is purchased as a “Work Made for Hire” whereby the clearing of any sampled materials is the responsibility of Licensee.

  • Monitoring of Servicers (a) The Master Servicer shall be responsible for reporting to the Trustee, the Trust Administrator and the Depositor the compliance by each Servicer with its duties under the related Servicing Agreement. In the review of each Servicer's activities, the Master Servicer may rely upon an officer's certificate of the Servicer with regard to such Servicer's compliance with the terms of its Servicing Agreement. In the event that the Master Servicer, in its judgment, determines that a Servicer should be terminated in accordance with its Servicing Agreement, or that a notice should be sent pursuant to such Servicing Agreement with respect to the occurrence of an event that, unless cured, would constitute grounds for such termination, the Master Servicer shall notify the Depositor, the Trust Administrator and the Trustee thereof and the Master Servicer shall issue such notice or take such other action as it deems appropriate. (b) The Master Servicer, for the benefit of the Trustee, the Trust Administrator and the Certificateholders, shall enforce the obligations of each Servicer under the related Servicing Agreement, and shall, in the event that a Servicer fails to perform its obligations in accordance with the related Servicing Agreement, subject to the preceding paragraph, terminate the rights and obligations of such Servicer thereunder and act as successor Servicer of the related Mortgage Loans or cause the Trustee to enter into a new Servicing Agreement with a successor Servicer selected by the Master Servicer; provided, however, it is understood and acknowledged by the parties hereto that there will be a period of transition (not to exceed 90 days) before the actual servicing functions can be fully transferred to such successor Servicer. Such enforcement, including, without limitation, the legal prosecution of claims, termination of Servicing Agreements and the pursuit of other appropriate remedies, shall be in such form and carried out to such an extent and at such time as the Master Servicer, in its good faith business judgment, would require were it the owner of the related Mortgage Loans. The Master Servicer shall pay the costs of such enforcement at its own expense, provided that the Master Servicer shall not be required to prosecute or defend any legal action except to the extent that the Master Servicer shall have received reasonable indemnity for its costs and expenses in pursuing such action. (c) To the extent that the costs and expenses of the Master Servicer related to any termination of a Servicer, appointment of a successor Servicer or the transfer and assumption of servicing by the Master Servicer with respect to any Servicing Agreement (including, without limitation, (i) all legal costs and expenses and all due diligence costs and expenses associated with an evaluation of the potential termination of the Servicer as a result of an event of default by such Servicer and (ii) all costs and expenses associated with the complete transfer of servicing, including all servicing files and all servicing data and the completion, correction or manipulation of such servicing data as may be required by the successor servicer to correct any errors or insufficiencies in the servicing data or otherwise to enable the successor servicer to service the Mortgage Loans in accordance with the related Servicing Agreement) are not fully and timely reimbursed by the terminated Servicer, the Master Servicer shall be entitled to reimbursement of such costs and expenses from the Collection Account. (d) The Master Servicer shall require each Servicer to comply with the remittance requirements and other obligations set forth in the related Servicing Agreement. (e) If the Master Servicer acts as Servicer, it will not assume liability for the representations and warranties of the Servicer, if any, that it replaces. (f) If a Servicer fails to make its required payment of Compensating Interest on any Distribution Date, the Master Servicer will be required to make such payment of Compensating Interest to the same extent that such Servicer was required to make such payment of Compensating Interest. (g) To the extent a Servicer requests the consent of the Trust or the Master Servicer with respect to any servicing-related matter for which the applicable Servicer is required to seek consent under the applicable Servicing Agreement or Assignment Agreement, the Master Servicer shall promptly or within the time frame specified in such Servicing Agreement, if any, evaluate such request for consent in the best interest of the Trust and the Certificateholders, and grant or withhold such consent accordingly.

  • Testing Landlord shall have the right to conduct annual tests of the Premises to determine whether any contamination of the Premises or the Project has occurred as a result of Tenant’s use. Tenant shall be required to pay the cost of such annual test of the Premises; provided, however, that if Tenant conducts its own tests of the Premises using third party contractors and test procedures acceptable to Landlord which tests are certified to Landlord, Landlord shall accept such tests in lieu of the annual tests to be paid for by Tenant. In addition, at any time, and from time to time, prior to the expiration or earlier termination of the Term, Landlord shall have the right to conduct appropriate tests of the Premises and the Project to determine if contamination has occurred as a result of Tenant’s use of the Premises. In connection with such testing, upon the request of Landlord, Tenant shall deliver to Landlord or its consultant such non-proprietary information concerning the use of Hazardous Materials in or about the Premises by Tenant or any Tenant Party. If contamination has occurred for which Tenant is liable under this Section 30, Tenant shall pay all costs to conduct such tests. If no such contamination is found, Landlord shall pay the costs of such tests (which shall not constitute an Operating Expense). Landlord shall provide Tenant with a copy of all third party, non-confidential reports and tests of the Premises made by or on behalf of Landlord during the Term without representation or warranty and subject to a confidentiality agreement. Tenant shall, at its sole cost and expense, promptly and satisfactorily remediate any environmental conditions identified by such testing in accordance with all Environmental Requirements. Landlord’s receipt of or satisfaction with any environmental assessment in no way waives any rights which Landlord may have against Tenant.

  • Inspection and Testing Each Constructing Entity shall cause inspection and testing of the Interconnection Facilities that it constructs in accordance with the provisions of this section. The Construction Parties acknowledge and agree that inspection and testing of facilities may be undertaken as facilities are completed and need not await completion of all of the facilities that a Constructing Entity is building.

  • Marketing of Production Except for contracts listed and in effect on the date hereof on Schedule 7.19, and thereafter either disclosed in writing to the Administrative Agent or included in the most recently delivered Reserve Report (with respect to all of which contracts the Borrower represents that it or its Subsidiaries are receiving a price for all production sold thereunder which is computed substantially in accordance with the terms of the relevant contract and are not having deliveries curtailed substantially below the subject Property’s delivery capacity), no material agreements exist which are not cancelable on 60 days notice or less without penalty or detriment for the sale of production from the Borrower’s or its Subsidiaries’ Hydrocarbons (including, without limitation, calls on or other rights to purchase, production, whether or not the same are currently being exercised) that (a) pertain to the sale of production at a fixed price and (b) have a maturity or expiry date of longer than six (6) months from the date hereof.

  • Monitoring of Servicer The Master Servicer shall be responsible for reporting to the Trustee, the Trust Administrator and the Depositor the non-compliance by the Servicer with its duties under this Agreement. In the review of the Servicer’s activities, the Master Servicer may rely upon an Officers’ Certificate of the Servicer (or similar document signed by a Servicing Officer of the Servicer) with regard to the Servicer’s compliance with the terms of this Agreement. In the event that the Master Servicer, in its good faith judgment, determines that the Servicer should be terminated in accordance with the terms hereof, or that a notice should be sent pursuant to the terms hereof with respect to the occurrence of an event that, unless cured, would constitute grounds for such termination, the Master Servicer shall notify the Depositor, the Trust Administrator and the Trustee thereof and the Master Servicer shall issue such notice or take such other action as it deems appropriate. The Master Servicer (or if the Master Servicer is the Servicer, the Trustee), for the benefit of the Certificateholders, shall enforce the obligations of the Servicer under this Agreement, and shall, in the event that it receives notice and confirms that the Servicer has failed to perform its obligations in accordance with this Agreement, subject to the preceding paragraph, terminate the rights and obligations of the Servicer hereunder and in accordance with the provisions of Article VII of this Agreement and act as Servicer of the Mortgage Loans or appoint a successor servicer; provided, however, it is understood and acknowledged by the parties hereto that there will be a period of transition (not to exceed 90 days) before the actual servicing functions can be fully transferred to such successor servicer. Such enforcement, including, without limitation, the legal prosecution of claims and the pursuit of other appropriate remedies, shall be in such form and carried out to such an extent and at such time as the Master Servicer or Trustee, as applicable, in its good faith business judgment, would require were it the owner of the Mortgage Loans. The Master Servicer or the Trustee, as applicable, shall pay the costs of such enforcement at its own expense, provided that the Master Servicer or the Trustee, as applicable, shall not be required to prosecute or defend any legal action except to the extent that the Master Servicer or the Trustee, as applicable, shall have received reasonable indemnity for its costs and expenses in pursuing such action. To the extent that the costs and expenses of the Master Servicer or Trustee, as applicable, related to any termination of the Servicer, appointment of a successor servicer or the transfer and assumption of servicing by the Master Servicer or the Trustee, as applicable, with respect to this Agreement (including, without limitation, (i) all legal costs and expenses and all due diligence costs and expenses associated with an evaluation of the potential termination of the Servicer as a result of a Servicer Event of Default and (ii) all costs and expenses associated with the complete transfer of servicing, including all servicing files and all servicing data and the completion, correction or manipulation of such servicing data as may be required by the successor servicer to correct any errors or insufficiencies in the servicing data or otherwise to enable the successor servicer to service the Mortgage Loans in accordance with this Agreement) are not fully and timely reimbursed by the terminated Servicer, the Master Servicer or the Trustee, as applicable, shall be entitled to reimbursement of such costs and expenses from the Distribution Account. The Master Servicer (or if the Master Servicer is the Servicer, the Trustee) shall, upon receipt from the Servicer, the Master Servicer or the Trust Administrator, of notice of any failure of the Servicer to comply with the remittance requirements and other obligations set forth in this Agreement, enforce such obligations. If the Master Servicer or the Trustee, as applicable, acts as Servicer, it will not assume liability for the representations and warranties of the Servicer that it replaces.

  • Periodic Review of Costs of Environmental Compliance In the ordinary course of its business, the Company conducts a periodic review of the effect of Environmental Laws on the business, operations and properties of the Company and its subsidiaries, in the course of which it identifies and evaluates associated costs and liabilities (including, without limitation, any capital or operating expenditures required for clean-up, closure of properties or compliance with Environmental Laws or any permit, license or approval, any related constraints on operating activities and any potential liabilities to third parties). On the basis of such review and the amount of its established reserves, the Company has reasonably concluded that such associated costs and liabilities would not, individually or in the aggregate, result in a Material Adverse Change.

  • Inspection and Tests 3.8.1 The Procuring entity or its representative shall have the right to inspect and/or to test the goods to confirm their conformity to the Contract specifications. The Procuring entity shall notify the tenderer in writing in a timely manner, of the identity of any representatives retained for these purposes. 3.8.2 The inspections and tests may be conducted in the premises of the tenderer or its subcontractor(s), at point of delivery, and/or at the Goods’ final destination If conducted on the premises of the tenderer or its subcontractor(s), all reasonable facilities and assistance, including access to drawings and production data, shall be furnished to the inspectors at no charge to the Procuring entity. 3.8.3 Should any inspected or tested goods fail to conform to the Specifications, the Procuring entity may reject the equipment, and the tenderer shall either replace the rejected equipment or make alterations necessary to make specification requirements free of costs to the Procuring entity. 3.8.4 The Procuring entity’s right to inspect, test and where necessary, reject the goods after the Goods’ arrival shall in no way be limited or waived by reason of the equipment having previously been inspected, tested and passed by the Procuring entity or its representative prior to the equipment delivery. 3.8.5 Nothing in paragraph 3.8 shall in any way release the tenderer from any warranty or other obligations under this Contract.

  • Updated Information Submission by Interconnection Customer The updated information submission by the Interconnection Customer, including manufacturer information, shall occur no later than one hundred eighty (180) Calendar Days prior to the Trial Operation. The Interconnection Customer shall submit a completed copy of the Electric Generating Unit data requirements contained in Appendix 1 to the LGIP. It shall also include any additional information provided to the Participating TO and the CAISO for the Interconnection Studies. Information in this submission shall be the most current Electric Generating Unit design or expected performance data. Information submitted for stability models shall be compatible with the Participating TO and CAISO standard models. If there is no compatible model, the Interconnection Customer will work with a consultant mutually agreed to by the Parties to develop and supply a standard model and associated information.

Draft better contracts in just 5 minutes Get the weekly Law Insider newsletter packed with expert videos, webinars, ebooks, and more!