Sewage Plant Chlorination System Scope Sample Clauses

Sewage Plant Chlorination System Scope. In order to ensure compliance to SANS 10298:2009, the scope of work shall include the following: Design a portable Chlorine dosing system suited for the application required at Camden’s Sewage Plant, complete with, but not limited to: • A customised container suitable for the storage of Chlorine gas, partitioned from roof to floor into 2 compartments to enable the separate storage of empty and full cylinders. The container must be designed to store the entire Chlorine dosing system and approximately 3 x 70kg cylinders per side. The container should have a ramp at the entrance to enable delivery or removal of Chlorine cylinders • Auto vacuum change over regulators with a maximum capacity of 2kg/hr with cylinder empty/full status indicator • System to be fitted with a flowrate controller 0 – 2kg/hr • System to be fitted with a free Chlorine analyser and a standard injector. The injector should be automated and controlled based on the free Chlorine analysis of the dosed stream • Gas monitoring system including a sensor and cable • Audible siren and flashing light for gas leak alarm (must be visible from distance of 500m) • Chlorine safety equipment box complete with: Chlorine cylinder spanner, full face gas mask with a spare canister, safety goggles, acid resistant PVC suit and a pair of acid resistant boots • Fitted with UPVC pipework, terminating with union ends just outside booth. NB. The Contractor will be responsible for all pipework required for the new dosing systems and for the tie-in to the existing plant • A foot operated safety shower with an eyewash bowl. NB. The Contractor will be responsible for all necessary pipework required for the potable water supply to the shower • All signage, labels and necessary emergency procedures • A scrubber for the safe removal of Chlorine gas from the storage container in the event of a gas leak • A cylinder trolley for the offloading of Chlorine cylinders • A calibrated platform scale with LED display • Extractor fan, Electrical DB box complete with sufficient lights and 1 x light switch and MCC (Motor Control Centre) for control logic between electronic modules. MCC should be able to operate extractor fan based on door position and leak detection. Contractor to assess current power supply available at respective 380V boards and determine if modifications are required and implement as such with approval from Employer • A control panel for all equipment installed inside the Chlorine storage container • Installatio...
AutoNDA by SimpleDocs

Related to Sewage Plant Chlorination System Scope

  • Underground Storage Tanks In accordance with the requirements of Section 3(g) of the D.C. Underground Storage Tank Management Act of 1990, as amended by the District of Columbia Underground Storage Tank Management Act of 1990 Amendment Act of 1992 (D.C. Code § 8-113.01, et seq.) (collectively, the “UST Act”) and the applicable D.C. Underground Storage Tank Regulations, 20 DCMR Chapter 56 (the “UST Regulations”), District hereby informs the Developer that it has no knowledge of the existence or removal during its ownership of the Property of any “underground storage tanks” (as defined in the UST Act). Information pertaining to underground storage tanks and underground storage tank removals of which the D.C. Government has received notification is on file with the District Department of the Environment, Underground Storage Tank Branch, 00 X Xxxxxx, X.X., Xxxxx Xxxxx, Xxxxxxxxxx, X.X., 00000, telephone (000) 000-0000. District’s knowledge for purposes of this Section shall mean and be limited to the actual knowledge of Xxxxxx Xxxxx, Property Acquisition and Disposition Division of the Department of Housing and Community Development, telephone no. (000) 000-0000. The foregoing is set forth pursuant to requirements contained in the UST Act and UST Regulations and does not constitute a representation or warranty by District.

  • Drainage Systems (1) Clear culvert inlets, outlets, and sediment catching basins. (2) Maintain waterbars, drainage dips, and other water diversion measures. (3) During active use, patrol and maintain functional drainage. (4) Repair damaged culvert ends.

  • Electrical appliance safety The Hirer shall ensure that any electrical appliances brought by them to the premises and used there shall be safe, in good working order, and used in a safe manner in accordance with the Electricity at Work Regulations 1989. Where a residual circuit breaker is provided the hirer must make use of it in the interests of public safety.

  • Wastewater investments in the construction, material enhancement, or renewal of infrastructure that supports wastewater and storm water collection, treatment, and management systems. Note: Investments in health infrastructure (e.g., hospitals, long-term care facilities, convalescent centres, and senior centres) are not eligible. Eligible Expenditures will be limited to the following: 1. Infrastructure investments – expenditures associated with acquiring, planning, designing, constructing, or renovating a tangible capital asset and any related debt financing charges specifically identified with that asset. 2. Capacity-building costs – for projects eligible under the capacity-building category only, expenditures associated with the development and implementation of: • Capital investment plans, integrated community sustainability plans, integrated regional plans, housing needs assessments, or asset management plans; • Studies, strategies, systems, software, third-party assessments, plans, or training related to asset management; • Studies, strategies, systems, or plans related to housing or land use; • Studies, strategies, or plans related to the long-term management of infrastructure; and • Other initiatives that strengthen the Recipient’s ability to improve local and regional planning. 3. Joint communications and signage costs – expenditures directly associated with joint federal communication activities and with federal project signage.

  • Underground Facilities All underground pipelines, conduits, ducts, cables, wires, manholes, vaults, tanks, tunnels, or other such facilities or attachments, and any encasements containing such facilities, including without limitation those that convey electricity, gases, steam, liquid petroleum products, telephone or other communications, cable television, water, wastewater, storm water, other liquids or chemicals, or traffic or other control systems.

  • Porcupine Site Highway 11 and the City of Timmins Thunder Bay and District Toronto/York-Peel

  • Plant The expression ‘Plant’ as used in the tender papers shall mean every temporary accessory necessary or considered necessary by the Engineer to execute, construct, complete and maintain the work and all altered, modified, substituted and additional works ordered in the time and the manner herein provided and all temporary materials and special and other articles and appliance of every sort kind and description whatsoever intended or used therefore.

  • Fuel The Vehicle must be returned with the amount of fuel equal to that at the time of the commencement of the rental. If the Vehicle is returned with less fuel, the difference will be charged to You at a rate of $5.00 per litre (which includes a service component).

  • Storage Tanks If storage tanks storing Hazardous Materials located on the Premises or the Project are used by Tenant or are hereafter placed on the Premises or the Project by Tenant, Tenant shall install, use, monitor, operate, maintain, upgrade and manage such storage tanks, maintain appropriate records, obtain and maintain appropriate insurance, implement reporting procedures, properly close any storage tanks, and take or cause to be taken all other actions necessary or required under applicable state and federal Legal Requirements, as such now exists or may hereafter be adopted or amended in connection with the installation, use, maintenance, management, operation, upgrading and closure of such storage tanks. Notwithstanding anything to the contrary contained herein, Tenant shall have no right to use or install any underground storage tanks at the Project.

  • Underground Tanks If underground or other storage tanks storing Hazardous Materials located on the Premises or the Project are used by Tenant or are hereafter placed on the Premises or the Project by Tenant, Tenant shall install, use, monitor, operate, maintain, upgrade and manage such storage tanks, maintain appropriate records, obtain and maintain appropriate insurance, implement reporting procedures, properly close any underground storage tanks, and take or cause to be taken all other actions necessary or required under applicable state and federal Legal Requirements, as such now exists or may hereafter be adopted or amended in connection with the installation, use, maintenance, management, operation, upgrading and closure of such storage tanks.