Specific Findings Chilcotin Study Area Sample Clauses

Specific Findings Chilcotin Study Area. Patch size was presented for both TSF and IFM methods in Xxxxxxx et al. (2002) Table 5.8, for the time period 1961-1922. These results are summarized below in Table 4.8. One discrepancy was found. In Xxxxxxx et al. Table 5.8 the total number of fires reported for IFM was indicated as 132. The total of the fires listed is 131. It is uncertain where this error came from but it is not significant in the general trend reported. Table 4.8 includes additional information required to present the data in a form that can be compared to the patch size distribution list in the Biodiversity Guidebook; namely an area calculation based on the number of fires in each class size. Class mid point values were used for this calculations. Choosing a mid point for the >50,000 class could skew results considerably, but the value chosen is likely in the ballpark. All areas are in hectares. Table 4.8 Summary of patch size from Xxxxxxx et al. Table 5.8 1961 to 1922. Patch size TSF (Time Since Fire) mapping IFM (Individual Fire Maps) Class Mid point Number Frequency Area % of total Area Number Frequency Area % of total Area 0-50 25 677 77.4% 16925 8% 55 42.0% 1375 1% 51-100 75 56 6.4% 4200 2% 11 8.4% 825 0% 101-200 150 40 4.6% 6000 3% 8 6.1% 1200 1% 201-500 250 45 5.1% 11250 5% 17 13.0% 4250 2% 501-1000 750 22 2.5% 16500 7% 11 8.4% 8250 3% 0000-0000 0000 29 3.3% 72500 32% 20 15.3% 50000 21% 5001-10,000 7500 3 0.3% 22500 10% 6 4.6% 45000 19% 10,000-50,000 25000 3 0.3% 75000 33% 2 1.5% 50000 21% >50,000 75000 0 0.0% 0 0% 1 0.8% 75000 32% Table 4.8 shows the smaller patch size indicated by the TSF method and shows a trend, by both methods, to large patches dominating the area of the landscape. The temporal scale of these results is very short. In Xxxxxxx et al. Table 5.9 patch size results by the TSF method for a longer period of time, present to 1675, are shown. It should be noted that this timer period is longer, but includes present to 1961 – the time of fire suppression. It is likely that this data is skewed to smaller patches. This data is summarized below in Table 4.9. Methodology is the same as that for Table 4.8. Table 4.9 Summary of patch size from Xxxxxxx et al. Table 5.9 TSF present to 1675. Patch size TSF mapping Class mid point number frequency Area % of total Area 0-50 25 1836 81.7% 45900 14% 51-100 75 130 5.8% 9750 3% 101-200 150 85 3.8% 12750 4% 201-500 250 96 4.3% 24000 8% 501-1000 750 46 2.0% 34500 11% 0000-0000 0000 47 2.1% 117500 37% 5001-10,000 7500 5 0.2% 37500 1...
AutoNDA by SimpleDocs

Related to Specific Findings Chilcotin Study Area

  • MSAA Indicator Technical Specification Document This Agreement shall be interpreted with reference to the MSAA Indicator Technical Specifications document.

  • Clinical Trials The studies, tests and preclinical and clinical trials conducted by or on behalf of, or sponsored by, the Company, or in which the Company has participated, that are described in the Registration Statement, the Time of Sale Disclosure Package or the Prospectus, or the results of which are referred to in the Registration Statement, the Time of Sale Disclosure Package or the Prospectus, were and, if still pending, are being conducted in all material respects in accordance with protocols, procedures and controls pursuant to, where applicable, accepted professional and scientific standards for products or product candidates comparable to those being developed by the Company and all applicable statutes, rules and regulations of the FDA, the EMEA, Health Canada and other comparable drug and medical device (including diagnostic product) regulatory agencies outside of the United States to which they are subject; the descriptions of the results of such studies, tests and trials contained in the Registration Statement, the Time of Sale Disclosure Package or the Prospectus do not contain any misstatement of a material fact or omit a material fact necessary to make such statements not misleading; the Company has no knowledge of any studies, tests or trials not described in the Disclosure Package and the Prospectus the results of which reasonably call into question in any material respect the results of the studies, tests and trials described in the Registration Statement, the Time of Sale Disclosure Package or Prospectus; and the Company has not received any notices or other correspondence from the FDA, EMEA, Health Canada or any other foreign, state or local governmental body exercising comparable authority or any Institutional Review Board or comparable authority requiring or threatening the termination, suspension or material modification of any studies, tests or preclinical or clinical trials conducted by or on behalf of, or sponsored by, the Company or in which the Company has participated, and, to the Company’s knowledge, there are no reasonable grounds for the same. Except as disclosed in the Registration Statement, the Time of Sale Disclosure Package and the Prospectus, there has not been any violation of law or regulation by the Company in its respective product development efforts, submissions or reports to any regulatory authority that could reasonably be expected to require investigation, corrective action or enforcement action.

  • Curriculum Vitae (a) The Chief Librarian shall maintain a curriculum vita for each Librarian. It is the Librarian’s responsibility to ensure that the curriculum vita on file is kept current. Members shall prepare their curriculum vita with the advice and assistance of their Chief Librarian. Members may revise their curriculum vita at any time.

  • Geological and Archeological Specimens If, during the execution of the Work, the Contractor, any Subcontractor, or any servant, employee, or agent of either should uncover any valuable material or materials, such as, but not limited to, treasure trove, geological specimens, archival material, archeological specimens, or ore, the Contractor acknowledges that title to the foregoing is vested in the Owner. The Contractor shall notify the Owner upon the discovery of any of the foregoing, shall take reasonable steps to safeguard it, and seek further instruction from the Design Professional. Any additional cost incurred by the Contractor shall be addressed under the provision for changed conditions. The Contractor agrees that the Geological and Water Resources Division and the Historic Preservation Division of the Georgia Department of Natural Resources may inspect the Work at reasonable times.

  • Technical Specifications The Technical Specifications furnished on the CD are intended to establish the standards for quality, performance and technical requirements for all labor, workmanship, material, methods and equipment necessary to complete the Work. When specifications and drawings are provided or referenced by the County, these are to be considered part of the Scope of Work, and to be specifically documented in the Detailed Scope of Work. For convenience, the County supplied specifications, if any, and the Technical Specifications furnished on the CD.

  • Programming Phase 2.2.1.2. Schematic Design Phase: 2.2.1.3. Design Development Phase:

  • Technical Standards Applicable to a Wind Generating Plant i. Low Voltage Ride-Through (LVRT) Capability A wind generating plant shall be able to remain online during voltage disturbances up to the time periods and associated voltage levels set forth in the standard below. The LVRT standard provides for a transition period standard and a post-transition period standard.

  • Technical Specification As enumerated in Special Conditions of Contract/Scope of Work/attached Drawing/ Details/Schedule of Rates.

  • Study An application for leave of absence for professional study must be supported by a written statement indicating what study or research is to be undertaken, or, if applicable, what subjects are to be studied and at what institutions.

  • Biological Samples If so specified in the Protocol, Institution and Principal Investigator may collect and provide to Sponsor or its designee Biological Samples (“Biological Samples”). 12.2.

Draft better contracts in just 5 minutes Get the weekly Law Insider newsletter packed with expert videos, webinars, ebooks, and more!