SRP IT Enterprise Testing and Acceptance. The contractor shall adhere to the SRPWeb Implementation and Operations Guide when testing and migrating SRP IT solutions to production. The contractor shall maintain and update a baseline test plan for all IT solutions. The contractor shall ensure that testing and release management encompasses the areas of data integrity, web application, and web services as well as comply with approved System Interface Agreement (SIA) and Service Level Agreement (SLA). The testing procedures shall detail each of the actors, the application's beginning state, user input, and expected results. The contractor shall be responsible for Internal System Testing (IST) of the application prior to Government Acceptance Testing (GAT). The contractor shall prepare and provide a GAT Test Plan prior to GAT. The contractor shall correct all software identified during GAT at no additional cost to the Government. Prior to moving the application to production, the contractor shall address all tests identified as unsatisfactory when the application is prepared for subsequent GAT. Migration to production shall be IAW the SRP Web Implementation and Operations Guide and the applicable SLAs.
AutoNDA by SimpleDocs

Related to SRP IT Enterprise Testing and Acceptance

  • Testing and Acceptance Within […***…] after RFM’s delivery of the IC Design File to ST, ST shall manufacture and deliver a commercially reasonable quantity of evaluation Product to RFM for evaluation testing. Upon RFM’s receipt of such Products from ST, RFM shall test such Products with the applicable Evaluation Software and in the applicable Evaluation Circuit Design to determine if the IC Design for such Products conforms to the applicable Specifications. Upon completion of such testing, RFM shall provide ST with the data from such testing (“Evaluation Data”). Upon ST’s receipt of the Evaluation Data, ST shall evaluate whether the Evaluation Data indicates that the IC Design conforms to the Specifications in all material respects. ST shall accept or reject the IC Design based on the Evaluation Data and shall give RFM written notice thereof within seven (7) calendar days after RFM’s delivery of the Evaluation Data to ST. An IC Design will be deemed accepted by ST if RFM has not received notification of rejection of such IC Design from ST within seven (7) calendar days after RFM’s delivery of the applicable Evaluation Data to ST. ST’s refusal to accept the IC Design must be reasonable, must be in writing and must be accompanied by a reasonably detailed description of the manner in which the IC Design fails to comply with the Specifications in all material respects (collectively, the “Deficiencies”) so that RFM can have the opportunity to correct the Deficiencies. If ST properly rejects the IC Design, RFM shall use commercially reasonable efforts to correct any Deficiencies and redeliver a corrected IC Design File within […***…] after RFM’s receipt of the rejection notice and the foregoing provisions set forth in this Section 3.3 shall be reapplied until the IC Design is accepted; provided, however, that upon the […***…] or any subsequent rejection, either party may terminate this Agreement upon thirty (30) calendar days prior written notice to the other party, unless the IC Design is accepted during such notice period.

  • Employment and Acceptance During the Term (as defined in Section 1.2), the Company shall employ the Executive, and the Executive shall accept such employment and serve the Company, in each case, subject to the terms and conditions of this Agreement.

  • INSPECTION AND ACCEPTANCE Cisco may reject any or all of the Work which does not conform to the applicable requirements within 10 business days of Supplier’s delivery of the Work. At Cisco’s option, Cisco may (i) return the non- conforming Work to Supplier for a refund or credit; (ii) requires Supplier to replace the non-conforming Work; or (iii) repair the non-conforming Work so that it meets the requirements. As an alternative to (i) through (iii), Cisco may accept the non-conforming Work conditioned on Supplier providing a refund or credit in an amount Cisco reasonably determines to represent the diminished value of the non-conforming Work. Cisco’s payment to Supplier for Work prior to Xxxxx’s timely rejection of such Work as non- conforming will not be deemed as acceptance by Xxxxx.

  • Synchronization, Commissioning and Commercial Operation 4.1.1 The Power Producer shall give at least fifteen (15) days written notice to the SLDC / ALDC / DISCOM as the case may be, of the date on which it intends to synchronize the Power Project to the Grid System. 4.1.2 Subject to Article 4.1.1, the Power Project may be synchronized by the Power Producer to the Grid System when it meets all the connection conditions prescribed in the Grid Code and otherwise meets all other Indian legal requirements for synchronization to the Grid System. 4.1.3 The synchronization equipment and all necessary arrangements / equipment including Remote Terminal Unit (RTU) for scheduling of power generated from the Project and transmission of data to the concerned authority as per applicable regulation shall be installed by the Power Producer at its generation facility of the Power Project at its own cost. The Power Producer shall synchronize its system with the Grid System only after the approval of GETCO / SLDC / ALDC and GEDA. 4.1.4 The Power Producer shall immediately after each synchronization / tripping of generator, inform the sub-station of the Grid System to which the Power Project is electrically connected in accordance with applicable Grid Code. 4.1.5 The Power Producer shall commission the Project within SCOD. 4.1.6 The Power Producer shall be required to obtain Developer and/ or Transfer Permission, Key Plan drawing etc, if required, from GEDA. In cases of conversion of land from Agricultural to Non-Agriculture, the commissioning shall be taken up by GEDA only upon submission of N.A. permission by the Power Producer. 4.1.7 The Power Producer shall be required to follow the Forecasting and Scheduling procedures as per the Regulations issued by Hon’ble GERC from time to time. It is to clarify that in terms of GERC (Forecasting, Scheduling, Deviation Settlement and Related Matters of Solar and Wind Generation Sources) Regulations, 2019 the procedures for Forecasting, Scheduling & Deviation Settlment are applicable to all solar generators having combined installed capacity above 1 MW connected to the State Grid / Substation including those connected via pooling stations.

  • Final Acceptance All Work has been completed and accepted by the County. The Contractor has provided all required close-out documentation and items as required by the Detailed Scope of Work for the specific Job Order, and these items and have accepted and approved by the County

  • Engagement; Acceptance The Issuer engages Xxxxxxx Fixed Income Services LLC to act as the Asset Representations Reviewer for the Issuer. Xxxxxxx Fixed Income Services LLC accepts the engagement and agrees to perform the obligations of the Asset Representations Reviewer on the terms in this Agreement.

  • Additional Acceptable Uses of Student Data Contractor is prohibited from using Student Data for any secondary use not described in this agreement except: a. for adaptive learning or customized student learning purposes; b. to market an educational application or product to a parent or legal guardian of a student if Contractor did not use Data, shared by or collected per this Contract, to market the educational application or product; c. to use a recommendation engine to recommend to a student i. content that relates to learning or employment, within the third-party contractor's internal application, if the recommendation is not motivated by payment or other consideration from another party; or

  • Acceptance Testing At the time of installation of a LIS trunk group, and at no additional charge, acceptance tests will be performed to ensure that the service is operational and meets the applicable technical parameters.

  • Screening and Assessment Grantee shall: 1. Comply with all applicable rules in the TAC for SUD programs as stated in the SUD UM Guidelines Information, Rules, and Regulations regarding Screening and Assessment. 2. When documenting a CMBHS Substance Use Disorder screening, Grantee shall conduct the screening in a confidential, face-to-face interview unless there is documented justification for an interview by phone. 3. Document Financial Eligibility in CMBHS as required in the SUD UM Guidelines. 4. Conduct and document a CMBHS SUD Initial Assessment with the client to determine the appropriate levels of care for SUD treatment. The CMBHS assessment will identify the impact of substances on the physical, mental health, and other identified issues including Tuberculosis, Hepatitis C, sexually transmitted infection (STI), and Human Immunodeficiency Virus (HIV). i. If client indicates risk for these communicable diseases, Grantee shall refer the client to the appropriate community resources for further testing and counseling. ii. If the client is at risk for HIV, Grantee shall refer the client to pre and post- test counseling on HIV. 5. Grantee will also consider referring to the TRA Statewide HIV Intensive Residential Treatment facility to concurrently address medical needs and SUD. 6. If a client is living with HIV, Grantee will refer the client to the appropriate community resources to complete the necessary referrals and health related paperwork. 7. The assessment shall be signed by a Qualified Credential Counselor (QCC) and filed in the client record within three (3) service days of admission or a program may accept an evaluation from an outside entity if it meets the criteria for admission and was completed during the thirty (30) business days preceding admission.

  • Post-Commercial Operation Date Testing and Modifications Each Party shall at its own expense perform routine inspection and testing of its facilities and equipment in accordance with Good Utility Practice as may be necessary to ensure the continued interconnection of the Large Generating Facility with the Participating TO’s Transmission System in a safe and reliable manner. Each Party shall have the right, upon advance written notice, to require reasonable additional testing of the other Party’s facilities, at the requesting Party’s expense, as may be in accordance with Good Utility Practice.