Transition Support Program Sample Clauses

Transition Support Program. (a) All references within this Article to the Transition Support Program relate to the Program outlined in Article 33. The availability of any payment or other entitlement under that document, and any obligation on the part of the Employer to provide such, pursuant to this Article or any other part of the collective agreement, shall only exist during the effective term of the Program, as expressly specified in that document. This limitation exists notwithstanding any other provision of this Article or any other part of the collective agreement.
AutoNDA by SimpleDocs
Transition Support Program. Notwithstanding anything in this Agreement, the Employer is only required to make a TSP payment to the same number of Employees as the Employer has reduced its complement.
Transition Support Program. 33.01 In order to avoid layoffs, Employees selected in accordance with TSP shall receive a severance payment in return for their voluntary resignation. TSP requires that a reduction in the staff complement occurs as a result of each TSP severance payment offered.
Transition Support Program. In order to avoid layoffs, employees selected in accordance with shall receive a severance payment in return for their voluntary resignation. requires that a reduction in the staff complement occurs as a result of each severance payment offered.

Related to Transition Support Program

  • Litigation Support In the event and for so long as any Party actively is contesting or defending against any charge, complaint, action, suit, proceeding, hearing, investigation, claim, or demand in connection with (i) any transaction contemplated under this Agreement or (ii) any fact, situation, circumstance, status, condition, activity, practice, plan, occurrence, event, incident, action, failure to act, or transaction on or prior to the Closing Date involving the Seller, the other Party will cooperate with the contesting or defending Party and its counsel in the contest or defense, make available his or its personnel, and provide such testimony and access to its books and records as shall be necessary in connection with the contest or defense, all at the sole cost and expense of the contesting or defending Party (unless the contesting or defending Party is entitled to indemnification therefor under Section 7 below).

  • Information Supplementation Prior to the Trial Operation date, the Parties shall supplement their information submissions described above in this Article 24 with any and all “as-built” Electric Generating Unit information or “as-tested” performance information that differs from the initial submissions or, alternatively, written confirmation that no such differences exist. The Interconnection Customer shall conduct tests on the Electric Generating Unit as required by Good Utility Practice such as an open circuit “step voltage” test on the Electric Generating Unit to verify proper operation of the Electric Generating Unit's automatic voltage regulator. Unless otherwise agreed, the test conditions shall include: (1) Electric Generating Unit at synchronous speed; (2) automatic voltage regulator on and in voltage control mode; and (3) a five percent (5 percent) change in Electric Generating Unit terminal voltage initiated by a change in the voltage regulators reference voltage. The Interconnection Customer shall provide validated test recordings showing the responses of Electric Generating Unit terminal and field voltages. In the event that direct recordings of these voltages is impractical, recordings of other voltages or currents that mirror the response of the Electric Generating Unit’s terminal or field voltage are acceptable if information necessary to translate these alternate quantities to actual Electric Generating Unit terminal or field voltages is provided. Electric Generating Unit testing shall be conducted and results provided to the Participating TO and the CAISO for each individual Electric Generating Unit in a station. Subsequent to the Commercial Operation Date, the Interconnection Customer shall provide the Participating TO and the CAISO any information changes due to equipment replacement, repair, or adjustment. The Participating TO shall provide the Interconnection Customer any information changes due to equipment replacement, repair or adjustment in the directly connected substation or any adjacent Participating TO-owned substation that may affect the Interconnection Customer’s Interconnection Facilities equipment ratings, protection or operating requirements. The Parties shall provide such information pursuant to Article 5.19.

  • Paid Claims without Supporting Documentation Any Paid Claim for which Xxxxx cannot produce documentation sufficient to support the Paid Claim shall be considered an error and the total reimbursement received by Xxxxx for such Paid Claim shall be deemed an Overpayment. Replacement sampling for Paid Claims with missing documentation is not permitted.

  • Listing Information Supply CBB shall provide to Verizon on a regularly scheduled basis, at no charge, and in a format required by Verizon or by a mutually agreed upon industry standard (e.g., Ordering and Billing Forum developed) all Listing Information and the service address for each CBB Customer whose service address location falls within the geographic area covered by the relevant Verizon directory. CBB shall also provide to Verizon on a daily basis: (a) information showing CBB Customers who have disconnected or terminated their service with CBB; and (b) delivery information for each non-listed or non-published CBB Customer to enable Verizon to perform its directory distribution responsibilities. Verizon shall promptly provide to CBB (normally within forty-eight (48) hours of receipt by Verizon, excluding non-business days) a query on any listing that is not acceptable.

  • Faculty Selection, Supervision, and Evaluation A. Faculty for a dual credit course will be approved and employed by Hill College. The instructor must meet credential requirements of Hill College and minimum requirements as specified by the Southern Association of Colleges and Schools Commission on Colleges (SACSCOC). Each faculty member assigned to teach an academic course will have a master’s degree plus 18 hours in the specific discipline. Technical course instructors will have at least an associate degree and three years of work experience in the related business or industry.

  • PRODUCT SUPPORT Partners may provide support for Products and other value-added services, and Partner is responsible for the performance of any services it provides. If Customer purchases Microsoft Support Services through a Partner, Microsoft will be responsible for the performance of those services subject to the terms of this Agreement. Pricing and payment If Customer orders from a Partner, the Partner will set Customer’s pricing and payment terms for that order, and Customer will pay the amount due to the Partner. Pricing and payment terms related to orders placed by Customer directly with Microsoft are set by Microsoft, and Customer will pay the amount due as described in this section.

Draft better contracts in just 5 minutes Get the weekly Law Insider newsletter packed with expert videos, webinars, ebooks, and more!