Transmission Provider Interconnection Facilities Sample Clauses

Transmission Provider Interconnection Facilities. 6.2.1 Energy Management System Databases to Support the Intertie The EMS (Energy Management System) personnel will need to model the actual generator plant (Multiple wind turbines will be considered as one plant.) in the EMS Generation Database and in the Dispatcher Training Simulator. Several values and status points will be modeled in the EMS SCADA (Supervisory Control and Data Acquisition) and Networking databases. These values include metering quantities and several monitoring quantities as well as status points. The values and monitoring points will be transmitted from the Tie Point RTU (Remote Terminal Unit) to the EMS SCADA over a communication circuit to be provided by the Generator (Interconnection Customer). Metering quantities include but are not limited to three phase currents, three phase voltages, instantaneous bi-directional megawatts, instantaneous bi-directional megavars, hourly megawatts delivered, hourly megawatts received, and power factor.
AutoNDA by SimpleDocs
Transmission Provider Interconnection Facilities. NWE Telecommunications will terminate an OPGW cable in the Xxxxx Junction control house that connects to the Xxxxxxxxx substation control house.  TERMINAL EQUIPMENT o Not Applicable  MICROWAVE OR FIBER EQUIPMENT o Fiber Patch/splice trays will be installed in the Xxxxx Junction Substation o ADSS fiber optic cable will be installed from a splice can on the dead end structure into the control house.
Transmission Provider Interconnection Facilities. Transmission Provider constructed, installed, and owns the interset pole required to interconnect Interconnection Customer’s 69 kV line at the Point of Interconnection. Transmission Provider shall own all facilities in its Transmission System up to the Point of Interconnection including the interset pole and the billing quality metering, transducers, RTU, Metering CTs and PTs, and metering panel all located in the Interconnection Customer’s substation control house.

Related to Transmission Provider Interconnection Facilities

  • Interconnection 2.1.10 Startup Testing and Commissioning

  • Common Facilities “Common Facilities” includes all areas, facilities, utilities, equipment and services provided by Landlord for the common use or benefit of the occupants of the Property, and their employees, agents, customers and other invitees, including without limitation building lobbies, common corridors and hallways, restrooms, pedestrian walkways, driveways and access roads, access facilities for disabled persons (including elevators), truck serviceways, loading docks, garages, driveways, parking lots, landscaped areas, stairways, elevators, retaining walls, all areas required to be maintained under the conditions of governmental approvals for the Property, comfort and first-aid stations, parcel pick-up stations and other generally understood public or common areas. All Common Facilities shall at all times be subject to the exclusive control and management of Landlord. Landlord shall have the right, without liability to Tenant, to relocate, alter, improve, or adjust the size and location of any Common Facilities from time to time, and Landlord shall have the right from time to time to establish, modify and enforce reasonable rules and regulations with respect to the Common Facilities. Landlord shall have the right to construct, maintain and operate lighting facilities on the Common Facilities; to police the same; from time to time to change the area, level, location and arrangement of parking areas and other facilities; to restrict parking by tenants, their officers, agents and employees to employee parking areas; to enforce parking charges (by operation of meters or otherwise), with appropriate provisions for free parking ticket validating by tenants; to close all or any portion of the Common Facilities to such extent as may, in the opinion of Landlord’s counsel, be legally sufficient to prevent a dedication thereof or the accrual of any rights to any person or the public therein; to close temporarily all or any portion of the Common Facilities; to discourage non-customer parking; and to do and perform such other acts in and to the Common Facilities which Landlord shall determine, using good business judgment, to be advisable to improve the convenience and use thereof by tenants, their officers, agents, employees and customers. Subject to the foregoing, Tenant may use all Common Facilities not within the Premises, under a revocable license, on a nonexclusive basis in common with other tenants. If any such license is revoked, or if the amount of such areas is diminished, Landlord shall not be subject to any liability and Tenant shall not be entitled to any compensation or abatement of rent, nor shall such revocation or diminution be deemed constructive or actual eviction.

  • Access to Facilities Each of the Company and each of its Subsidiaries will permit any representatives designated by the Purchaser (or any successor of the Purchaser), upon reasonable notice and during normal business hours, at such person's expense and accompanied by a representative of the Company, to:

  • Communications Equipment Members of the board of directors or any committee thereof may participate in and act at any meeting of such board or committee through the use of a conference telephone or other communications equipment by means of which all persons participating in the meeting can hear each other, and participation in the meeting pursuant to this section shall constitute presence in person at the meeting.

  • Metering The Interconnection Customer shall be responsible for the Connecting Transmission Owner’s reasonable and necessary cost for the purchase, installation, operation, maintenance, testing, repair, and replacement of metering and data acquisition equipment specified in Attachments 2 and 3 of this Agreement. The Interconnection Customer’s metering (and data acquisition, as required) equipment shall conform to applicable industry rules and Operating Requirements.

  • Monitoring System In each case in which the Custodian has exercised delegated authority to place Assets with a Foreign Custodian, the Custodian shall establish a system, to re-assess or re-evaluate selected Foreign Custodians, at least annually in accordance with Rule 17f-5(c)(3).

  • Other Facilities This Agreement reserves in each party the power to establish a temporary holding facility during a pandemic, riot, civil disobedience or natural disaster, to establish group homes or other care or rehabilitation facilities in furtherance of a social service program, to temporarily transfer Inmates to alternative detention facilities in order to respond to Xxxx overcrowding, a public health directive, or to comply with a final order of a federal court or a state court of record for the care and treatment of Inmates.

  • Generator Subject to the provisions of this Section 29.36, Tenant shall be entitled to install, operate and maintain a generator and any other equipment related thereto, including, without limitation, a fuel system, wiring and shaft space (“Generator”) next to the Building at Tenant’s sole cost and expense (without paying any additional fee or rental to Landlord for the use thereof). Prior to the installation of the Generator, Tenant shall inspect the proposed location to determine a suitable location for the Generator, and Tenant shall submit written plans and specifications relative to the type, size and proposed location (including any proposed screening) of the Generator to Landlord for its review and written approval. Tenant shall be solely responsible for the cost of acquisition, installation, operation, and maintenance of the Generator; and Tenant shall install, maintain and operate the Generator in accordance with all federal, state, and local laws, statutes, ordinances, rules and regulations, including without limitation, obtaining and maintaining any and all permits, approvals and licenses required to install and operate the Generator by any governmental authority having jurisdiction. Landlord and Tenant agree that, upon the expiration of earlier termination of the Lease Term, Tenant shall not be required to remove the Generator, any associated cabling, wiring and screening or other improvements. Tenant shall not be entitled to grant or assign to any third party (other than a permitted assignee of Tenant’s rights under the Lease or a permitted subtenant relative to the Premises (or a portion thereof)) the right to use the Generator without Landlord’s prior written consent (which consent may be granted or withheld in Landlord’s discretion). Upon reasonable advance notice to Tenant (and provided Landlord reasonably coordinates with Tenant and provides an alternate source of backup generator capacity during said transition), Landlord shall be entitled to cause the Generator to be moved to another location near the Building, at Landlord’s cost and expense. Tenant shall pay all personal property taxes on the Generator. Tenant shall also pay any increases in the real property taxes of the Building due to the installation of the Generator within thirty (30) days of receipt of notice from Landlord which includes proof of such increase in taxes. Tenant’s indemnity obligations under Section 5.4.1.5 of the Lease, relating to the use of Hazardous Materials, shall apply to the use and operation of the Generator. Finally, Tenant’s insurance obligations under Section 10.3 of the Lease shall apply to the Generator.

  • Computer Transmission The Custodian is able to accept transmissions sent from the Fund’s computer facilities to the Custodian’s computer facilities. If the Fund determines to use its proprietary transmission or other electronic transmission method, it must provide Custodian sufficient notice and information to allow testing or other confirmation that FT Instructions received via the Fund Designated Security Procedure can be processed in good time and order. The Custodian may require the Fund to execute additional documentation prior to the use of such transmission method.