Where Connection Point exceeds threshold Sample Clauses

Where Connection Point exceeds threshold. (a) This clause 6.2 applies in respect of a Connection Point where: (i) the Generating Plant with installed capacity exceeding 30 kVA is Connected at the Connection Point; or (ii) the Connection Assets for the Connection Point is operated at 66 kV or greater; or (iii) the rating of the largest motor Connected at the Connection Point is greater than 0.4% of the three phase short circuit fault level at the Attachment Point. (b) Western Power, acting as a Reasonable and Prudent Person, may at any time on reasonable technical or commercial grounds object to a Controller nominated by the User under clause 6.1, in which case the User must either:
AutoNDA by SimpleDocs

Related to Where Connection Point exceeds threshold

  • Under-Frequency and Over Frequency Conditions The New York State Transmission System is designed to automatically activate a load- shed program as required by the NPCC in the event of an under-frequency system disturbance. Developer shall implement under-frequency and over-frequency relay set points for the Large Generating Facility as required by the NPCC to ensure “ride through” capability of the New York State Transmission System. Large Generating Facility response to frequency deviations of predetermined magnitudes, both under-frequency and over-frequency deviations, shall be studied and coordinated with the NYISO and Connecting Transmission Owner in accordance with Good Utility Practice. The term “ride through” as used herein shall mean the ability of a Generating Facility to stay connected to and synchronized with the New York State Transmission System during system disturbances within a range of under-frequency and over-frequency conditions, in accordance with Good Utility Practice and with NPCC Regional Reliability Reference Directory # 12, or its successor.

  • Interconnection Facility Options The Intercarrier Compensation provisions of this Agreement shall apply to the exchange of Exchange Service (EAS/Local) traffic between CLEC's network and Qwest's network. Where either Party acts as an IntraLATA Toll provider, each Party shall xxxx the other the appropriate charges pursuant to its respective tariff or price lists. Where either Party interconnects and delivers traffic to the other from third parties, each Party shall xxxx such third parties the appropriate charges pursuant to its respective tariffs, price lists or contractual offerings for such third party terminations. Absent a separately negotiated agreement to the contrary, the Parties will directly exchange traffic between their respective networks without the use of third party transit providers.

  • CLEC OUTAGE For a problem limited to one CLEC (or a building with multiple CLECs), BellSouth has several options available for restoring service quickly. For those CLECs that have agreements with other CLECs, BellSouth can immediately start directing traffic to a provisional CLEC for completion. This alternative is dependent upon BellSouth having concurrence from the affected CLECs. Whether or not the affected CLECs have requested a traffic transfer to another CLEC will not impact BellSouth's resolve to re-establish traffic to the original destination as quickly as possible.

  • Planned Outages Seller shall schedule Planned Outages for the Project in accordance with Good Industry Practices and with the prior written consent of Buyer, which consent may not be unreasonably withheld or conditioned. The Parties acknowledge that in all circumstances, Good Industry Practices shall dictate when Planned Outages should occur. Seller shall notify Buyer of its proposed Planned Outage schedule for the Project for the following calendar year by submitting a written Planned Outage schedule no later than October 1st of each year during the Delivery Term. The Planned Outage schedule is subject to Buyer’s approval, which approval may not be unreasonably withheld or conditioned. Buyer shall promptly respond with its approval or with reasonable modifications to the Planned Outage schedule and Seller shall use its best efforts in accordance with Good Industry Practices to accommodate Xxxxx’s requested modifications. Notwithstanding the submission of the Planned Outage schedule described above, Seller shall also submit a completed Outage Notification Form to Buyer no later than fourteen (14) days prior to each Planned Outage and all appropriate outage information or requests to the CAISO in accordance with the CAISO Tariff. Seller shall contact Buyer with any requested changes to the Planned Outage schedule if Seller believes the Project must be shut down to conduct maintenance that cannot be delayed until the next scheduled Planned Outage consistent with Good Industry Practices. Seller shall not change its Planned Outage schedule without Buyer’s approval, not to be unreasonably withheld or conditioned. Seller shall use its best efforts in accordance with Good Industry Practices not to schedule Planned Outages during the months of July, August, September and October. At Buyer’s request, Seller shall use commercially reasonable efforts to reschedule Planned Outage so that it may deliver Product during CAISO declared or threatened emergency periods. Seller shall not substitute Energy from any other source for the output of the Project during a Planned Outage.

  • Minimum Amounts and Maximum Number of Tranches All borrowings, prepayments, conversions and continuations of Loans hereunder and all selections of Interest Periods hereunder shall be in such amounts and be made pursuant to such elections so that, after giving effect thereto, the aggregate principal amount of the Loans comprising each Eurodollar Tranche shall be equal to $10,000,000 or a whole multiple of $1,000,000 in excess thereof. In no event shall there be more than five Eurodollar Tranches outstanding at any time.

  • Participating TO’s Interconnection Facilities The Participating TO shall design, procure, construct, install, own and/or control the Participating TO’s Interconnection Facilities described in Appendix A at the sole expense of the Interconnection Customer. Unless the Participating TO elects to fund the capital for the Participating TO’s Interconnection Facilities, they shall be solely funded by the Interconnection Customer.

  • Threshold Neither the Seller nor the Purchaser shall be required to make any indemnification payment pursuant to Section 8.1 or 8.2, respectively, until such time as the total amount of all Damages that have been directly or indirectly suffered or incurred by an Indemnified Party, or to which an Indemnified Party has or otherwise becomes subject to, exceeds $50,000 in the aggregate. At such time as the total amount of such Damages exceeds $50,000 in the aggregate, the Indemnified Party shall be entitled to be indemnified against the full amount of such Damages (and not merely the portion of such Damages exceeding $50,000).

  • Reallocation to a Class with a Lower Salary Range Maximum 1. If the employee meets the skills and abilities requirements of the position and chooses to remain in the reallocated position, the employee retains the existing appointment status and has the right to be placed on the Employer’s internal layoff list for the classification occupied prior to the reallocation. 2. If the employee chooses to vacate the position or does not meet the skills and abilities requirements of the position, the layoff procedure specified in Article 31 of this Agreement applies.

  • Cost Responsibility for Interconnection Facilities and Distribution Upgrades 4.1 Interconnection Facilities 4.2 Distribution Upgrades

  • Reactive Power and Primary Frequency Response 9.6.1 Power Factor Design Criteria