Adult Holding Ponds and Handling Facilities Sample Clauses

Adult Holding Ponds and Handling Facilities. The adult facilities layout (see Section B, C, and Plan View in Appendix 7 – Salmon Hatchery Remodel Components) has some similarities to the method used at the Xxxx Xxxxxx Hatchery in Oregon. Nine (9) 15’w x 75’l adult ponds are proposed to share an 8 foot wide common crowding channel via removable bulkheads. A dedicated xxxxxxx is proposed to assist with the batching of adults into an electroanesthesia lift through a flap gate at the end of the crowding channel. After the fish are anesthetized, they may be lifted to the level of the spawning table in the new adult handing building. From the spawning table inside the adult handling building, the operator will be able to return unripe fish to ponds, perform vaccinations, drain blood from fish, remove eggs and/or xxxx, deliver steelhead to recovery tanks, kill fish, and plate freeze carcasses. It may also be desirable to have the ability to temporarily store some fish in small tanks or load anesthetized adults into a tanker truck by lifting fish to a delivery chute above spawning table. Adults will be delivered to holding ponds via 15” diameter transfer pipes which originate at either the separation or adult handling facilities. The crowding channel’s dedicated xxxxxxx may also be provided with the ability to lift any of the pond bulkheads. The adult ponds are proposed to have a minimum of two portable crowders that may be moved from pond to pond using either a forklift or an overhead gantry system. Crowders used in adult trout ponds will not be used in adult salmon ponds to minimize spread of disease. In addition, the water surface elevation in crowding channel may be kept approximately 1 foot lower than water level of adult holding ponds. The goals achieved by the proposed adult layout (see Appendix No. 7 – Salmon Hatchery Remodel Components) include the following: 1. Operation and maintenance access around majority of ponds. 2. Minimal disturbance of fish by workers and visitors. 3. Access road to fish ladder can remain. 4. Physical separation from juvenile ponds. 5. Shortest possible route for egg transfer to hatchery building. 6. Convenient visitor and truck access to adult handling area. 7. More pond volume provided than specified by IHOT criteria. 8. Shortest possible route for sorting tubes from separation facility. 9. Centralized formalin storage in new adult handling facility for treatment of all adult salmon and trout ponds. 10. Two ponds may be served by a pathogen light water supply (e.g. sprin...
AutoNDA by SimpleDocs

Related to Adult Holding Ponds and Handling Facilities

  • Access Toll Connecting Trunk Group Architecture 9.2.1 If CSTC chooses to subtend a Verizon access Tandem, CSTC’s NPA/NXX must be assigned by CSTC to subtend the same Verizon access Tandem that a Verizon NPA/NXX serving the same Rate Center Area subtends as identified in the LERG. 9.2.2 CSTC shall establish Access Toll Connecting Trunks pursuant to applicable access Tariffs by which it will provide Switched Exchange Access Services to Interexchange Carriers to enable such Interexchange Carriers to originate and terminate traffic to and from CSTC’s Customers. 9.2.3 The Access Toll Connecting Trunks shall be two-way trunks. Such trunks shall connect the End Office CSTC utilizes to provide Telephone Exchange Service and Switched Exchange Access to its Customers in a given LATA to the access Tandem(s) Verizon utilizes to provide Exchange Access in such LATA. 9.2.4 Access Toll Connecting Trunks shall be used solely for the transmission and routing of Exchange Access to allow CSTC’s Customers to connect to or be connected to the interexchange trunks of any Interexchange Carrier which is connected to a Verizon access Tandem.

  • External Hosting Facilities DST shall implement controls, consistent with applicable prevailing industry practices and standards, regarding the collection, use, storage and/or disclosure of Fund Data by an external hosting provider.

  • Generating Facility The Interconnection Customer’s device for the production of electricity identified in the Interconnection Request, but shall not include the Interconnection Customer’s Interconnection Facilities.

  • Interconnection Facilities Engineering Procurement and Construction Interconnection Facilities, Network Upgrades, and Distribution Upgrades shall be studied, designed, and constructed pursuant to Good Utility Practice. Such studies, design and construction shall be based on the assumed accuracy and completeness of all technical information received by the Participating TO and the CAISO from the Interconnection Customer associated with interconnecting the Large Generating Facility.

  • Developer Attachment Facilities Developer shall design, procure, construct, install, own and/or control the Developer Attachment Facilities described in Appendix A hereto, at its sole expense.

  • Verizon OSS Facilities Any gateways, interfaces, databases, facilities, equipment, software, or systems, used by Verizon to provide Verizon OSS Services to ICG.

  • Toilet Facilities The Employer provides the Contractor access to toilet facilities. Temporary chemical toilets are provided by the Contractor where deemed necessary.

  • State Facilities If the State makes space available to the Party in any State facility during the term of this Agreement for purposes of the Party’s performance under this Agreement, the Party shall only use the space in accordance with all policies and procedures governing access to and use of State facilities which shall be made available upon request. State facilities will be made available to Party on an “AS IS, WHERE IS” basis, with no warranties whatsoever.

  • Trading Facilities Most open-outcry and electronic trading facilities are supported by computer-based component systems for the order-routing, execution, matching, registration or clearing of trades. As with all facilities and systems, they are vulnerable to temporary disruption or failure. Your ability to recover certain losses may be subject to limits on liability imposed by the system provider, the market, the clearing house and/or member firms. Such limits may vary; you should ask the firm with which you deal for details in this respect.

  • Existing Facilities Each of the Existing Facilities shall be repaid in full and terminated and all collateral security therefor shall be released, and the Administrative Agent shall have received pay-off letters in form and substance satisfactory to it evidencing such repayment, termination and release.

Draft better contracts in just 5 minutes Get the weekly Law Insider newsletter packed with expert videos, webinars, ebooks, and more!