Airport Security/Public Safety and Emergency Response Sample Clauses

Airport Security/Public Safety and Emergency Response. Future airport fencing and security will be evaluated to ensure adequate airport security and to keep the general public out of aircraft operation areas. The existing emergency response will be identified and recommendations for the future will be provided. • Consultant: Evaluate landside facility requirements and formulate recommendations. • Sponsor: Review and comment on Consultant recommendations, if necessary.
AutoNDA by SimpleDocs

Related to Airport Security/Public Safety and Emergency Response

  • Emergency Response Partners must develop, maintain, and carry out a response plan for public water system emergencies, including disease outbreaks, spills, operational failures, and water system contamination. Partners must notify DWS in a timely manner of emergencies that may affect drinking water supplies.

  • Health, Safety and Security 14.1 The Employer recognizes a responsibility to provide an environment intended to protect the health, safety and security of Members as they carry out their responsibilities. To that end, the Employer agrees: (a) to maintain a Joint Health and Safety Committee (the JHSC) with broad representation drawn from all sectors of the University, including at least one (1) person appointed by the Association; (b) to cooperate with the Association in making every reasonable provision for the safety, health and security of Members; (c) to take reasonable measures to maintain the security of the buildings and grounds while at the same time maintaining reasonable access for Members who have a need for such access at times other than during regular working hours; (d) to ensure that the Association has the right to appoint at least one (1) person to any representative committee whose terms of reference specifically include the health, safety or security of Members as they carry out their responsibilities; (e) to comply with the Occupational Health and Safety Act, R.S.O. 1990, and relevant regulations thereto, as amended from time to time (the “Act”); (f) that Members may refuse unsafe work pursuant to and in accordance with the relevant provisions of the Act for so doing; (g) that Members report any known or potential dangers to their Xxxx; (h) In addition, the Employer agrees: i) to provide Members with health and safety training, personal protective equipment, and access to health and safety programs, policies and procedures; ii) to provide resources for the JHSC; iii) to compensate a CASBU Member who is eligible to be, and serves as, the person appointed by the Association to the JHSC when that service is outside the period of the Member’s contract; iv) to provide training for the person appointed by the Association to the JHSC directly related to their duties and responsibilities in connection with the JHSC; v) to recognize a JHSC Member’s right to be present during workplace safety testing and audits and receive written copies of any reports and recommendations from the testing/audits and a copy of a draft report if one is provided to the Employer; vi) to recognize a JHSC Member’s right to have advance notice when advance notice is given by the Ministry of Labour of any Ministry of Labour inspection and to accompany a Ministry of Labour Inspector during an inspection and receive a copy of any report produced by the inspector. 14.2 The parties agree that all personal communications must adhere to the Personal Harassment and Discrimination Policy and the Nipissing University Acceptable Use Policy. Effective June 10, 2006, universities are subject to the Freedom of Information and Protection of Privacy Act (FIPPA). All records in the custody and control of the University will be subject to FIPPA with exceptions as defined by the Act. Persons may request and have a right to access University information or records. A record is defined under the Act as any record of information however recorded, whether in printed or electronic form, film, or otherwise and includes drafts, post-it notes, margin notes, hard drive files, emails, voice mails, electronic agendas, address books, and recording devices. 14.3 Unless required under FIPPA, and for the purposes of this Article, files are documents under a Member’s control and stored on University property, either in paper or electronic form. Such files do not include the Member’s official file in the Xxxx’x office nor the Personnel File of the Member in the Human Resources office. 14.4 On termination of a Member’s employment for any reason other than cause, the Employer will permit, by appointment only, accompanied access for a period of fifteen (15) working days (or longer with the agreement of the Xxxx) by the former Member or the Member’s executors to the Member’s files, whether in paper or electronic format. The purpose of the allowed access is for transferring required documents to other faculty, the Chair, or the Xxxx. Where files are not required to support continued student academic needs or ongoing operational requirements, the former Member or designate may remove or destroy their personal files. Items that are clearly of a personal nature or are owned by the former Member such as furniture, pictures, books, etc., may be removed at this time.

  • Agency Response a. OGS will consider all information relevant to the Formal Dispute, and may, in its discretion, suspend, modify, or cancel the disputed procurement/Contract action prior to issuance of a Formal Dispute decision. b. OGS reserves the right to require the filer to meet or participate in a conference call with OGS to discuss the Formal Dispute when, in its sole judgment, circumstances so warrant. c. OGS reserves the right to waive or extend the time requirements for decisions and final determinations on appeals herein prescribed when, in its sole judgment, circumstances so warrant. d. OGS reserves the right to consider or reject the merits of any Formal Dispute.

  • HEALTH, SAFETY AND ENVIRONMENT In the performance of this Contract, Contractor and Operator shall conduct Petroleum Operations with due regard to health, safety and the protection of the environment (“HSE”) and the conservation of natural resources, and shall in particular:

  • Contingent Emergency Response 1. In order to ensure the proper implementation of contingent emergency response activities under Part 4 of the Project (“Contingent Emergency Response Part”), the Recipient shall ensure that: (a) a manual (“CERC Manual”) is prepared and adopted in form and substance acceptable to the Association, which shall set forth detailed implementation arrangements for the Contingent Emergency Response Part, including: (i) any structures or institutional arrangements for coordinating and implementing the Contingent Emergency Response Part;

  • Fraud, Waste, and Abuse Contractor understands that HHS does not tolerate any type of fraud, waste, or abuse. Violations of law, agency policies, or standards of ethical conduct will be investigated, and appropriate actions will be taken. Pursuant to Texas Government Code, Section 321.022, if the administrative head of a department or entity that is subject to audit by the state auditor has reasonable cause to believe that money received from the state by the department or entity or by a client or contractor of the department or entity may have been lost, misappropriated, or misused, or that other fraudulent or unlawful conduct has occurred in relation to the operation of the department or entity, the administrative head shall report the reason and basis for the belief to the Texas State Auditor’s Office (SAO). All employees or contractors who have reasonable cause to believe that fraud, waste, or abuse has occurred (including misconduct by any HHS employee, Grantee officer, agent, employee, or subcontractor that would constitute fraud, waste, or abuse) are required to immediately report the questioned activity to the Health and Human Services Commission's Office of Inspector General. Contractor agrees to comply with all applicable laws, rules, regulations, and System Agency policies regarding fraud, waste, and abuse including, but not limited to, HHS Circular C-027. A report to the SAO must be made through one of the following avenues: ● SAO Toll Free Hotline: 1-800-TX-AUDIT ● SAO website: xxxx://xxx.xxxxx.xxxxx.xx.xx/ All reports made to the OIG must be made through one of the following avenues: ● OIG Toll Free Hotline 0-000-000-0000 ● OIG Website: XxxxxxXxxxxXxxxx.xxx ● Internal Affairs Email: XxxxxxxxXxxxxxxXxxxxxxx@xxxx.xxxxx.xx.xx ● OIG Hotline Email: XXXXxxxxXxxxxxx@xxxx.xxxxx.xx.xx. ● OIG Mailing Address: Office of Inspector General Attn: Fraud Hotline MC 1300 P.O. Box 85200 Austin, Texas 78708-5200

  • Rectification of Safety Hazard Where, because of the existence of a safety hazard, a site has been stopped for a defined period of time and Employees sent off site by agreement between Site Managers and any combination of Union Official/s, Health and Safety Committee, those people who remain on site to do rectification work will be paid at the rate of double time for all such work.

  • Fire Safety Resident will not tamper with fire alarms, smoke detectors, fire extinguishers, fire hoses, or exit signs. Resident will promptly evacuate Residence Facility upon the sounding of an alarm or as otherwise directed by College Housing staff. Resident will participate in any periodic fire drill and fire safety training conducted by College for the Residence Facility.

  • Primary Frequency Response Developer shall ensure the primary frequency response capability of its Large Generating Facility by installing, maintaining, and operating a functioning governor or equivalent controls. The term “functioning governor or equivalent controls” as used herein shall mean the required hardware and/or software that provides frequency responsive real power control with the ability to sense changes in system frequency and autonomously adjust the Large Generating Facility’s real power output in accordance with the droop and deadband parameters and in the direction needed to correct frequency deviations. Developer is required to install a governor or equivalent controls with the capability of operating: (1) with a maximum 5 percent droop ± 0.036 Hz deadband; or (2) in accordance with the relevant droop, deadband, and timely and sustained response settings from an approved Applicable Reliability Standard providing for equivalent or more stringent parameters. The droop characteristic shall be: (1) based on the nameplate capacity of the Large Generating Facility, and shall be linear in the range of frequencies between 59 and 61 Hz that are outside of the deadband parameter; or (2) based on an approved Applicable Reliability Standard providing for an equivalent or more stringent parameter. The deadband parameter shall be: the range of frequencies above and below nominal (60 Hz) in which the governor or equivalent controls is not expected to adjust the Large Generating Facility’s real power output in response to frequency deviations. The deadband shall be implemented: (1) without a step to the droop curve, that is, once the frequency deviation exceeds the deadband parameter, the expected change in the Large Generating Facility’s real power output in response to frequency deviations shall start from zero and then increase (for under-frequency deviations) or decrease (for over-frequency deviations) linearly in proportion to the magnitude of the frequency deviation; or (2) in accordance with an approved Applicable Reliability Standard providing for an equivalent or more stringent parameter. Developer shall notify NYISO that the primary frequency response capability of the Large Generating Facility has been tested and confirmed during commissioning. Once Developer has synchronized the Large Generating Facility with the New York State Transmission System, Developer shall operate the Large Generating Facility consistent with the provisions specified in Articles 9.5.5.1 and 9.5.5.2 of this Agreement. The primary frequency response requirements contained herein shall apply to both synchronous and non-synchronous Large Generating Facilities.

  • Safety and Security Procedures Contractor shall maintain and enforce, at the Contractor Work Locations, industry-standard safety and physical security policies and procedures. While at each Court Work Location, Contractor shall comply with the safety and security policies and procedures in effect at such Court Work Location.

Draft better contracts in just 5 minutes Get the weekly Law Insider newsletter packed with expert videos, webinars, ebooks, and more!