Balance of Plant Support Systems Sample Clauses

Balance of Plant Support Systems. The BOP support systems include, but are not limited to, the following: One Distributed Control System (DCS) for the simple cycle facility and balance‑of‑plant (BOP) control, data acquisition and data analysis. One natural gas system One liquid fuel system, if applicable Ammonia unloading, storage, and transfer systems Interconnecting piping for combustion turbine liquid fuel system, if applicable Cooling water systems Raw water treatment system Water treatment system Fire/filtered water storage tank Demineralized water storage tanks Chemical storage and injection systems Hypochlorite storage and injection system , if required Domestic (potable) water system, including well or utility interconnect Sanitary waste system Process waste water system Fire detection, alarm, and suppression systems Instrument air system Service air system Permanent Facility communications system Heating, ventilating and air conditioning (HVAC) systems Storm water management system Sampling system Emergency power system, including emergency electric power generator Electric power distribution system Lighting system Lightning protection system Cathodic protection system Freeze Protection system, if required by environmental conditions. Grounding system Expansion joints Roads (including the access road), fencing and parking Transmission interconnection facilities, Continuous Emissions Monitoring System (CEMS), and Data Acquisition and Handling System (DAHS) Administrative and maintenance buildings Bottled gas storage (e.g., CEMS, CO2) Natural gas line and on-site metering station per the pipeline company interconnect requirements Electrical transmission tie-in Interfaces with the above temporary or mobile systems including mobile demineralizer trailers.
AutoNDA by SimpleDocs
Balance of Plant Support Systems. The BOP support systems include, but are not limited to, the following: One Distributed Control System (DCS) for the combined cycle facility and balance‑of‑plant (BOP) control, data acquisition and data analysis. One natural gas system One liquid fuel system, if applicable Main steam systems, for each of the power islands, each including cascade-type turbine bypass for high pressure, intermediate pressure and reheat steam, and turbine bypass directly to the condenser Condensate systems Feedwater systems HRSG blowdown systems Ammonia unloading, storage, and transfer systems Interconnecting piping for combustion turbine liquid fuel system (if applicable), and for steam turbine steam/condensate drain, lube oil, and seal steam systems Condenser and cooling towers or air cooled condensers and auxiliaries Cooling water systems (including Wet Surface Air Condenser (WSAC) if necessary for an air cooled configuration) Raw water treatment system Cycle makeup water treatment system Feed water tank Fire/filtered water storage tank Demineralized water storage tanks Chemical storage and injection systems for the condensate and feedwater systems Hypochlorite storage and injection system , if required Domestic (potable) water system, including well or utility interconnect Sanitary waste system Process waste water system Fire detection, alarm, and suppression systems Instrument air system Service air system Permanent Facility communications system Heating, ventilating and air conditioning (HVAC) systems Storm water management system Sampling system Emergency power system, including emergency electric power generator Electric power distribution system Lighting system Lightning protection system Cathodic protection system Freeze Protection system, if required by environmental conditions Grounding system Expansion joints Roads (including the access road), fencing and parking Transmission interconnection facilities, Continuous Emissions Monitoring System (CEMS), and Data Acquisition and Handling System (DAHS) Administrative and maintenance buildings Hydrogen gas trailer or skid (if applicable,) and other bottle gases (e.g., CEMS, CO2) Natural gas line and on-site metering station per the pipeline company interconnect requirements Electrical transmission tie-in Interfaces with the above temporary or mobile systems including mobile demineralizer trailers.

Related to Balance of Plant Support Systems

  • STUDENT SUPPORT SERVICES The Parties will identify and collaborate on measures to assist those students who may not be performing satisfactorily to succeed. The School will seek guidance from the College designee(s) in the areas of test preparation, tutoring, College Connection services, academic advising, and the development of an integrated support system for Students across the two institutions. Students will have access to the same or similar tutoring and other academic support as provided for other students in the School District, School and College. To promote academic success, the Parties will provide academic support services as may be needed. The School counselor and its designee will work to ensure Students receive pertinent information regarding higher education, financial assistance, and assistance waivers for tuition and fees. As needed, each Party will assist families as they complete initial application and admission requirements per the respective organizations’ processes. The School District will be responsible for non-academic counseling services and the College is authorized, but not required, to provide emergency counseling intervention services. See section 4 – Disability Support Services.

  • Selection of Subcontractors, Procurement of Materials and Leasing of Equipment The contractor shall not discriminate on the grounds of race, color, religion, sex, national origin, age or disability in the selection and retention of subcontractors, including procurement of materials and leases of equipment. The contractor shall take all necessary and reasonable steps to ensure nondiscrimination in the administration of this contract.

  • PRODUCT SUPPORT a. In the event that any goods delivered under this contract become defective or malfunction for any reason and at any time (even after the applicable warranty period has expired), including while “in-orbit” if integrated into a satellite, Seller shall promptly perform a failure verification or analysis and determine the appropriate corrective action at no additional cost to Buyer. Seller shall take the appropriate measures to correct all defects, determined to be Seller's responsibility, in all applicable documentation, undelivered goods, and delivered un-launched goods, as required by Buyer.

  • Maintenance and Support Services As long as you are not using the Help Desk as a substitute for our training services on the Tyler Software, and you timely pay your maintenance and support fees, we will, consistent with our then-current Support Call Process:

  • Paid Claims without Supporting Documentation Any Paid Claim for which Practitioner cannot produce documentation shall be considered an error and the total reimbursement received by Practitioner for such Paid Claim shall be deemed an Overpayment. Replacement sampling for Paid Claims with missing documentation is not permitted.

  • Operations Support Systems Verizon systems for pre-ordering, ordering, provisioning, maintenance and repair, and billing.

  • Academic Policies and Student Support Services X. Xxxx College courses offered as dual credit, regardless of where they are taught, follow the same syllabus, course outline, textbook, grading method, and other academic policies and procedures as the courses outlined in the Hill College policy manual, catalog, and student handbook. [TAC 19, Part 1, Chapter 4, Subchapter D, 4.85(g)(1)]

  • Maintenance of Services 5.1 Services resold pursuant to this Attachment and BellSouth’s General Subscriber Service Tariff and Private Line Service Tariff and facilities and equipment provided by BellSouth shall be maintained by BellSouth.

  • Innovative Scheduling Schedules which are inconsistent with the Collective Agreement provisions may be developed in order to improve quality of working life, support continuity of resident care, ensure adequate staffing resources, and support cost-efficiency. The parties agree that such innovative schedules may be determined locally by the Home and the Union subject to the following principles:

  • Maintenance of Equipment The Equipment shall be maintained in good operating condition and repair (reasonable wear and tear excepted) and all necessary replacements of and repairs thereto shall be made so that the value and operating efficiency of the Equipment shall be maintained and preserved. No Borrower shall use or operate the Equipment in violation of any law, statute, ordinance, code, rule or regulation. Each Borrower shall have the right to sell Equipment to the extent set forth in Section 4.3 hereof.

Time is Money Join Law Insider Premium to draft better contracts faster.