Compliance Monitoring Well Network/Performance Monitoring Plan Sample Clauses

Compliance Monitoring Well Network/Performance Monitoring Plan. An acceptable Performance Monitoring Plan based on a compliance monitoring well network sufficient to monitor the Non-Expansion Cleanup Objective must be established. The DNRE has identified a number of locations where there may be gaps in the current definition of the plume and where additional xxxxx need to be installed (described below). The Parties’ technical staffs have agreed upon the installation of borings/monitoring xxxxx as described below, however DNRE reserves the right to request the installation of additional borings/monitoring xxxxx if the totality of the data from these xxxxx indicate that the plume has not been completely defined. These boring/monitoring xxxxx will provide further definition of the extent of groundwater contamination so that the Parties can identify compliance monitoring points for monitoring the revised performance objective for the Western Area4: • A boring south of Third Sister Lake, near the MWs named Saginaw Forest Cabin (SFC) #1&2, will be drilled to determine if there is any dioxane that needs to be monitored in the vertical interval between the screens at SFC #1&2. PLS will vertically profile every ten feet throughout the saturated interval. DNRE expects that the interval that corresponds to the screen in SFC#1 will be about 30 ppb, about the same as SFC#1. DNRE recommends that the use of water during the drilling be avoided during this boring, or that PLS installs a temporary well at the appropriate intermediate depth(s) to ensure that the vertical profile result accurately reflects the actual concentration. DNRE understands that PLS may not want to install another MW if it can confirm there is no need to monitor this depth; however, DNRE will require a permanent MW(s) screened at the appropriate intermediate depth(s) if it has a reasonable basis for questioning the vertical profiling results.
AutoNDA by SimpleDocs

Related to Compliance Monitoring Well Network/Performance Monitoring Plan

  • Performance Monitoring ‌ A. Performance Monitoring of Subrecipient by County, State of California and/or HUD shall consist of requested and/or required written reporting, as well as onsite monitoring by County, State of California or HUD representatives. B. County shall periodically evaluate Subrecipient’s progress in complying with the terms of this Contract. Subrecipient shall cooperate fully during such monitoring. County shall report the findings of each monitoring to Subrecipient. C. County shall monitor the performance of Subrecipient against the goals, outcomes, milestones and performance standards required herein. Substandard performance, as determined by County, will constitute non-compliance with this Contract for which County may immediately terminate the Contract. If action to correct such substandard performance is not taken by Subrecipient within the time period specified by County, payment(s) will be denied in accordance with the provisions contained in this Paragraph 47 of this Contract. D. HUD in accordance with 24 CFR Part 570 Subpart O, 570.902, will annually review the performance of County to determine whether County has carried out its Community Development Block Grant (CDBG) assisted activities in a timely manner and has significantly disbursed CDBG funds and met the mandated “1.5 ratio” threshold. Subrecipient is responsible to ensure timely drawdown of funds.

  • PERFORMANCE MANAGEMENT SYSTEM 6.1 The Performance Plan (Annexure A) to this Agreement sets out – 6.1.1 The standards and procedures for evaluating the Employee’s performance; and 6.1.2 The intervals for the evaluation of the Employee’s performance. 6.2 Despite the establishment of agreed intervals for evaluation, the Employer may in addition review the Employee’s performance at any stage while the contract of employment remains in force; 6.3 Personal growth and development needs identified during any performance review discussion must be documented in a Personal Development Plan as well as the actions agreed to and implementation must take place within set time frames; 6.4 The Employee’s performance will be measured in terms of contributions to the goals and strategies set out in the Employer’s Integrated Development Plan (IDP) as described in 6.6 – 6.12 below; 6.5 The Employee will submit quarterly performance reports (SDBIP) and a comprehensive annual performance report at least one week prior to the performance assessment meetings to the Evaluation Panel Chairperson for distribution to the panel members for preparation purposes; 6.6 Assessment of the achievement of results as outlined in the performance plan: 6.6.1 Each KPI or group of KPIs shall be assessed according to the extent to which the specified standards or performance targets have been met and with due regard to ad-hoc tasks that had to be performed under the KPI, and the score of the employer will be given to and explained to the Employee during the assessment interview. 6.6.2 A rating on the five-point scale shall be provided for each KPI or group of KPIs which will then be multiplied by the weighting to calculate the final score; 6.6.3 The Employee will submit his self-evaluation to the Employer prior to the formal assessment; 6.6.4 In the instance where the employee could not perform due to reasons outside the control of the employer and employee, the KPI will not be considered during the evaluation. The employee should provide sufficient evidence in such instances; and 6.6.5 An overall score will be calculated based on the total of the individual scores calculated above.

  • Performance Management 17.1 The Contractor will appoint a suitable Account Manager to liaise with the Authority’s Strategic Contract Manager. Any/all changes to the terms and conditions of the Agreement will be agreed in writing between the Authority’s Strategic Contract Manager and the Contractor’s appointed representative. 17.2 The Contractor will ensure that there will be dedicated resources to enable the smooth running of the Framework Agreement and a clear plan of contacts at various levels within the Contractor's organisation. Framework Public Bodies may look to migrate to this Framework Agreement as and when their current contractual arrangements expire. The Contractor will where necessary assign additional personnel to this Framework Agreement to ensure agreed service levels are maintained and to ensure a consistent level of service is delivered to all Framework Public Bodies. 17.3 In addition to annual meetings with the Authority's Strategic Contract Manager, the Contractor is expected to develop relationships with nominated individuals within each of the Framework Public Bodies to ensure that the level of service provided on a local basis is satisfactory. Where specific problems are identified locally, the Contractor will attempt to resolve such problems with the nominated individual within that organisation. The Authority's Strategic Contract Manager will liaise (or meet as appropriate) regularly with the Framework Public Bodies' Contract Manager, and where common problems are identified, it will be the responsibility of the Contractor to liaise with the Authority's Strategic Contract Manager to agree a satisfactory course of action. Where the Contractor becomes aware of a trend that would have a negative effect on one or more of the Framework Public Bodies, they should immediately notify the Authority's Strategic Contract Manager to discuss corrective action. 17.4 Regular meetings, frequency to be advised by Framework Public Body, will be held between the Framework Public Bodies' Contract Manager and the Contractor's representative to review the performance of their Call-Off Contract(s) under this Framework Agreement against the agreed service levels as measured through Key Performance Indicators (KPIs). Reports will be provided by the Contractor to the Framework Public Bodies' Contract Manager at least 14 days prior to the these meetings. 17.5 Performance review meetings will also be held annually, between the Authority's Strategic Contract Manager and the Contractor's representative to review the performance of the Framework Agreement against the agreed service levels as measured through Key Performance Indicators. A summary of the quarterly reports will be provided by the Contractor at least 14 days prior to these meetings. 17.6 The Authority will gather the outputs from contract management to review under the areas detailed in the table below. Provision of management reports 90% to be submitted within 10 working days of the month end Report any incident affecting the delivery of the Service(s) to the Framework Public Body 100% to be reported in writing to FPB within 24 hours of the incident being reported by telephone/email Prompt payment of sub-contractors and/or consortia members (if applicable). Maximum of 30 from receipt of payment from Framework Public Bodies, 10 days target 100% within 30 days

  • Compliance Monitoring Grantee must be subject to compliance monitoring during the period of performance in which funds are Expended and up to three years following the closeout of all funds. In order to assure that the program can be adequately monitored, the following is required of Grantee: a. Grantee must maintain a financial tracking system provided by Florida Housing that ensures that CRF funds are Expended in accordance with the requirements in this Agreement. b. Grantee must maintain records on all awards to Eligible Persons or Households. These records must include, but are not limited to: i. Proof of income compliance (documentation from submission month, including but not limited to paystub, Florida unemployment statement, social security and/or disability statement, etc.); ii. Lease; and iii. Documentation of rental assistance payments made.

  • Performance Testing 7.2.1 The Design-Builder shall direct and supervise the tests and, if necessary, the retests of the Plant using Design-Builder’s supervisory personnel and the Air Emissions Tester shall conduct the air emissions test, in each case, in accordance with the testing procedures set forth in Exhibit A (the “Performance Tests”), to demonstrate, at a minimum, compliance with the Performance Guarantee Criteria. Owner is responsible for obtaining Air Emissions Tester and for ensuring Air Emissions Tester’s timely performance. Design-Builder shall cooperate with the Air Emissions Tester to facilitate performance of all air emissions tests. Design-Builder shall not be held responsible for the actions of Owner’s employees and third parties involved in the Performance Testing, including but not limited to Air Emissions Tester. 7.2.2 No later than thirty (30) Days prior to the earlier of the Scheduled Substantial Completion Date or Substantial Completion, Design-Builder shall provide to Owner for review a detailed testing plan for the Performance Tests (other than for air emissions). Owner and Design-Builder shall agree upon a testing plan that shall be consistent with the Performance Test Protocol contained in Exhibit A hereto. After such agreement has been reached, Design-Builder shall notify the Owner five (5) business days prior to the date Design-Builder intends to commence the Performance Tests and shall notify the Owner upon commencement of the Performance Tests. Owner and Independent Engineer each have the right to witness all testing, including the Performance Tests and any equipment testing, whether at the Site or at the Subcontractor’s or equipment supplier’s premises during the course of this Agreement. Notwithstanding the foregoing sentence, Owner shall bear the costs of providing a witness to any such testing and all such witnesses shall comply at all times with Design-Builder’s, Subcontractor’s or equipment supplier’s safety and security procedures and other reasonable requirements, and otherwise conduct themselves in a manner that does not interfere with Design-Builder’s, Subcontractor’s or equipment supplier’s activities or operations. 7.2.3 Design-Builder shall provide to Owner a Performance Test report (excluding results from air emissions testing), including all applicable test data, calculations and certificates indicating the results of the Performance Tests and, within five (5) business days of Owner’s receipt of such results, Owner, Independent Engineer and Design-Builder will jointly inspect such Work and review the results of the Performance Tests to verify that the Performance Guarantee Criteria have been met. If Owner or Independent Engineer reasonably determines that the Performance Guarantee Criteria have not been met, Owner shall notify Design-Builder the reasons why Owner determined that the Performance Guarantee Criteria have not been met and Design-Builder shall promptly take such action or perform such additional work as will achieve the Performance Guarantee Criteria and shall issue to the Owner another notice in accordance with Section 7.2.2; provided however that if the notice relates to a retest, the notice may be provided no less than two (2) business days prior to the Performance Tests. Such procedure shall be repeated as necessary until Owner and Independent Engineer verifies that the Performance Guarantee Criteria have been met. 7.2.4 If Owner, for whatever reason, prevents Design-Builder from demonstrating the Performance Guarantee Criteria within thirty (30) Days of Design-Builder’s notice that the Plant is ready for Performance Testing, then Design-Builder shall be excused from demonstrating compliance with the Performance Guarantee Criteria during such period of time that Design-Builder is prevented from demonstrating compliance with the Performance Guarantee Criteria; provided however that Design-Builder will be deemed to have fulfilled all of its obligations to demonstrate that the Plant meets the Performance Guarantee Criteria should such period of time during which Design-Builder is prevented from demonstrating the Performance Criteria exceed thirty (30) Days or extend beyond the Final Completion Date.

  • CONTRACTOR PERFORMANCE AUDIT The Contractor shall allow the Authorized User to assess Contractor’s performance by providing any materials requested in the Authorized User Agreement (e.g., page load times, response times, uptime, and fail over time). The Authorized User may perform this Contractor performance audit with a third party at its discretion, at the Authorized User’s expense. The Contractor shall perform an independent audit of its Data Centers, at least annually, at Contractor expense. The Contractor will provide a data owner facing audit report upon request by the Authorized User. The Contractor shall identify any confidential, trade secret, or proprietary information in accordance with Appendix B, Section 9(a), Confidential/Trade Secret Materials.

  • Annual Performance Review The Employee’s performance of his duties under this Agreement shall be reviewed by the Board of Directors or a committee of the Board of Directors at least annually and finalized within thirty (30) days of the receipt of the annual audited financial statements. The Board of Directors or a committee of the Board of Directors shall additionally review the base salary, bonus and benefits provided to the Employee under this Agreement and may, in their discretion, adjust the same, as outlined in Addendum B of this Agreement, provided, however, that Employee’s annual base salary shall not be less than the base salary set forth in Section 4(A) hereof.

  • Ongoing Performance Measures The Department intends to use performance-reporting tools in order to measure the performance of Contractor(s). These tools will include the Contractor Performance Survey (Exhibit H), to be completed by Customers on a quarterly basis. Such measures will allow the Department to better track Vendor performance through the term of the Contract(s) and ensure that Contractor(s) consistently provide quality services to the State and its Customers. The Department reserves the right to modify the Contractor Performance Survey document and introduce additional performance-reporting tools as they are developed, including online tools (e.g. tools within MFMP or on the Department's website).

  • Quarterly Contractor Performance Reporting Customers shall complete a Contractor Performance Survey (Exhibit I) for each Contractor on a Quarterly basis. Customers will electronically submit the completed Contractor Performance Survey(s) to the Department Contract Manager no later than the due date indicated in Contract Exhibit D, Section 17, Additional Special Contract Conditions. The completed Contractor Performance Survey(s) will be used by the Department as a performance-reporting tool to measure the performance of Contractors. The Department reserves the right to modify the Contractor Performance Survey document and introduce additional performance-reporting tools as they are developed, including online tools (e.g. tools within MyFloridaMarketPlace or on the Department's website).

  • Registry Performance Specifications Registry Performance Specifications for operation of the TLD will be as set forth in Specification 10 attached hereto (“Specification 10”). Registry Operator shall comply with such Performance Specifications and, for a period of at least one (1) year, shall keep technical and operational records sufficient to evidence compliance with such specifications for each calendar year during the Term.

Draft better contracts in just 5 minutes Get the weekly Law Insider newsletter packed with expert videos, webinars, ebooks, and more!