Connection of New Receipt Points Sample Clauses

Connection of New Receipt Points. The Parties agree as follows with respect to new Receipt Points. (a) If Shipper is drilling a new well, or xxxxx, that would require the addition of a new Receipt Point, Shipper shall provide notice to Gatherer (the “Receipt Point Notice”). The Receipt Point Notice shall include the desired location, the required completion date for Gatherer to have its Facilities in place in conjunction with Shipper constructing road access, if required, to the Receipt Point, the desired capacity of the Receipt Point, and an updated production forecast, if necessary, for the new Receipt Point as well as the applicable portions of the Gathering System. When reasonably practical, Shipper shall provide notice of its projected needs for new Receipt Points at least one hundred and twenty (120) Days prior to the need for such Receipt Point, but lack of such notice does not relieve Gatherer of its obligations hereunder. Shipper shall provide the Receipt Point Notice at least thirty (30) Days prior to the expected completion date for Gatherer to have its Facilities in place in conjunction with the completion of the construction of the access road. Within three (3) Business Days of the Receipt Point Notice, Gatherer shall begin the process of determining potential pipeline routes and the necessary right-of-way, permits, and materials to construct any new Facilities required to connect the new Receipt Point to the Gathering System. Within ten (10) Business Days of the Receipt Point Notice, Gatherer shall provide Shipper with a written response of the design and completion date of the new Receipt Point. If the design and completion date is acceptable to Shipper, Shipper will advise Gatherer in writing within three (3) Business *** Certain information in this document has been omitted and filed separately with the Securities and Exchange Commission. Confidential treatment has been requested with respect to the omitted portions. Days after receiving such estimate, and Gatherer will complete construction of the new connection Facilities for such Receipt Point with due diligence. Gatherer shall be responsible for all costs, including overhead, associated with installation of the new lateral and required metering and sampling equipment. Provided that Shipper provides sufficient notice, Gatherer shall cooperate in good faith with Shipper to minimize the overall impact to landowners and the environment by coordinating, and cooperating with respect to, (i) installation (and related construc...
AutoNDA by SimpleDocs

Related to Connection of New Receipt Points

  • Interconnection Customer’s Interconnection Facilities The Interconnection Customer shall design, procure, construct, install, own and/or control the Interconnection Customer’s Interconnection Facilities described in Appendix A at its sole expense.

  • Participating TO’s Interconnection Facilities The Participating TO shall design, procure, construct, install, own and/or control the Participating TO’s Interconnection Facilities described in Appendix A at the sole expense of the Interconnection Customer. Unless the Participating TO elects to fund the capital for the Participating TO’s Interconnection Facilities, they shall be solely funded by the Interconnection Customer.

  • All new supplies equipment and services shall include manufacturer's minimum standard warranty unless otherwise agreed to in writing. Vendor shall be legally permitted to sell all products offered for sale to TIPS Members. All goods proposed and sold shall be new unless clearly stated in writing. The Vendor shall provide timely and accurate customer support for orders to TIPS Members as agreed by the Parties. Vendors shall respond to such requests within a commercially reasonable time after receipt of the request. If support andƒor training is a line item sold or packaged with a sale, support shall be as agreed with the TIPS Member. Most TIPS Members are tax exempt and the related laws andƒor regulations of the controlling jurisdiction(s) of the TIPS Member shall apply. No assignment of Agreement may be made without the prior notification of TIPS. Written approval of TIPS shall not be unreasonably withheld. Payment for delivered goods and services can only be made to the awarded Vendor, Vendor designated reseller or vendor assigned company.

  • Cost Responsibility for Interconnection Facilities and Distribution Upgrades 4.1 Interconnection Facilities 4.2 Distribution Upgrades

  • Interconnection Facilities 4.1.1 The Interconnection Customer shall pay for the cost of the Interconnection Facilities itemized in Attachment 2 of this Agreement. The NYISO, in consultation with the Connecting Transmission Owner, shall provide a best estimate cost, including overheads, for the purchase and construction of its Interconnection Facilities and provide a detailed itemization of such costs. Costs associated with Interconnection Facilities may be shared with other entities that may benefit from such facilities by agreement of the Interconnection Customer, such other entities, the NYISO, and the Connecting Transmission Owner. 4.1.2 The Interconnection Customer shall be responsible for its share of all reasonable expenses, including overheads, associated with (1) owning, operating, maintaining, repairing, and replacing its own Interconnection Facilities, and

  • Interconnection Facility Options The Intercarrier Compensation provisions of this Agreement shall apply to the exchange of Exchange Service (EAS/Local) traffic between CLEC's network and Qwest's network. Where either Party acts as an IntraLATA Toll provider, each Party shall xxxx the other the appropriate charges pursuant to its respective tariff or price lists. Where either Party interconnects and delivers traffic to the other from third parties, each Party shall xxxx such third parties the appropriate charges pursuant to its respective tariffs, price lists or contractual offerings for such third party terminations. Absent a separately negotiated agreement to the contrary, the Parties will directly exchange traffic between their respective networks without the use of third party transit providers.

  • Interconnection Facilities Engineering Procurement and Construction Interconnection Facilities, Network Upgrades, and Distribution Upgrades shall be studied, designed, and constructed pursuant to Good Utility Practice. Such studies, design and construction shall be based on the assumed accuracy and completeness of all technical information received by the Participating TO and the CAISO from the Interconnection Customer associated with interconnecting the Large Generating Facility.

  • NETWORK INTERCONNECTION METHODS 3.1 The Interconnection provided herein may not be used solely for the purpose of originating a Party’s own interexchange traffic.

  • Connecting Transmission Owner’s Attachment Facilities Construction The Connecting Transmission Owner’s Attachment Facilities shall be designed and constructed in accordance with Good Utility Practice. Upon request, within one hundred twenty (120) Calendar Days after the Commercial Operation Date, unless the Connecting Transmission Owner and Developer agree on another mutually acceptable deadline, the Connecting Transmission Owner shall deliver to the Developer “as-built” drawings, relay diagrams, information and documents for the Connecting Transmission Owner’s Attachment Facilities set forth in Appendix A. The Connecting Transmission Owner [shall/shall not] transfer operational control of the Connecting Transmission Owner’s Attachment Facilities and Stand Alone System Upgrade Facilities to the NYISO upon completion of such facilities.

  • Interconnection Customer Provided Services The services provided by Interconnection Customer under this LGIA are set forth in Article 9.6 and Article 13.5. 1. Interconnection Customer shall be paid for such services in accordance with Article 11.6.