Drilling of Test Well Sample Clauses

Drilling of Test Well. On or before the expiration of the Term of this Agreement subject, however, to rig availability and obtaining requisite governmental permits, COI shall commence, or cause to be commenced, the drilling of the Test Well, at a location on the Leases mutually acceptable to the Parties, and shall prosecute same in a diligent and workmanlike manner to the Objective Depth. In the event the Test Well does not reach the Objective Depth due to encountering impenetrable substances or mechanical conditions beyond COI’s reasonable control, the Parties shall have the option, but not the obligation, to commence the drilling of a substitute well at a mutually acceptable location on the Leases. Any such substitute well drilled hereunder shall, upon its commencement, thereafter be deemed the Test Well. In the event COI does not drill a Test Well during the Term of this Agreement on a Lease, COI shall assign 100% of the record title interest to such Lease and all of the operating rights interest to such Lease to XXX within 30 days of expiration of the Term. XXX shall then be under no further obligations to COI with regard to such Lease and shall therefore be free to drill or cause to be drilled REX’s Prospect(s) on such Lease.
AutoNDA by SimpleDocs
Drilling of Test Well. Synergy, after consultation with Vecta (and any third party owners to whom Vecta or Synergy may sell, assign, transfer or convey portions of their interests in the Vecta Vecta Greenhorn Project Leases, the Vecta Greenhorn Project Supplemental Leases and/or the Synergy Greenhorn Project Leases), shall propose the drilling and completion of a new well to evaluate the Greenhorn formation (hereafter the “Test Well Objective Formation”); and may select a drill site or drill sites within the project area to evaluate either the Test Well Objective Formation or other objective specified in the proposal for such well or xxxxx pursuant to the provisions of the Project JOA. Following interpretation of the data derived from the seismic program referenced in Section 7.2.a above, Synergy shall use reasonable efforts in good faith to spud on or before October 31, 2013, a well (referred to as the “Initial Greenhorn Test Well”) at a legal location in Section 1 of Township 6 North, Range 59 West, 6th P. M., Xxxxxx County, Colorado. The Initial Greenhorn Test Well shall be drilled to a depth sufficient to penetrate and adequately test the D-sand and J-sand formations, and shall thereafter be plugged back to the Greenhorn formation for the express purpose of drilling an extended reach lateral of not less than four thousand feet (4,000’) within said Section 1 of Township 6 North, Range 59 West. Following completion of the lateral, Synergy shall attempt to complete the horizontal leg of the well utilizing a multi-stage frac stimulation mutually designed and agreed upon by the Parties. Vecta shall provide technical assistance to Synergy during the course of operations, including, but not limited to geological oversight and engineering consultation. The costs of drilling the Initial Greenhorn Test Well shall be borne 65.00% by Vecta (and any partners secured by Vecta) and 35.00% by Synergy. All costs for operations and production after the completion of the Initial Greenhorn Test Well, as well as any costs for acquisition of additional seismic data or leasehold, or for the drilling of additional xxxxx, shall be borne in accordance with the elections of the parties under the Project JOA. Under the Project JOA, Synergy shall have a 35.00% working interest and Vecta (and any partners of Vecta) shall have a cumulative 65.00% working interest subject to the non-consent and non-participation penalties set forth therein.

Related to Drilling of Test Well

  • Acceptance Testing At the time of installation of a LIS trunk group, and at no additional charge, acceptance tests will be performed to ensure that the service is operational and meets the applicable technical parameters.

  • Performance Testing 7.2.1 The Design-Builder shall direct and supervise the tests and, if necessary, the retests of the Plant using Design-Builder’s supervisory personnel and the Air Emissions Tester shall conduct the air emissions test, in each case, in accordance with the testing procedures set forth in Exhibit A (the “Performance Tests”), to demonstrate, at a minimum, compliance with the Performance Guarantee Criteria. Owner is responsible for obtaining Air Emissions Tester and for ensuring Air Emissions Tester’s timely performance. Design-Builder shall cooperate with the Air Emissions Tester to facilitate performance of all air emissions tests. Design-Builder shall not be held responsible for the actions of Owner’s employees and third parties involved in the Performance Testing, including but not limited to Air Emissions Tester. 7.2.2 No later than thirty (30) Days prior to the earlier of the Scheduled Substantial Completion Date or Substantial Completion, Design-Builder shall provide to Owner for review a detailed testing plan for the Performance Tests (other than for air emissions). Owner and Design-Builder shall agree upon a testing plan that shall be consistent with the Performance Test Protocol contained in Exhibit A hereto. After such agreement has been reached, Design-Builder shall notify the Owner five (5) business days prior to the date Design-Builder intends to commence the Performance Tests and shall notify the Owner upon commencement of the Performance Tests. Owner and Independent Engineer each have the right to witness all testing, including the Performance Tests and any equipment testing, whether at the Site or at the Subcontractor’s or equipment supplier’s premises during the course of this Agreement. Notwithstanding the foregoing sentence, Owner shall bear the costs of providing a witness to any such testing and all such witnesses shall comply at all times with Design-Builder’s, Subcontractor’s or equipment supplier’s safety and security procedures and other reasonable requirements, and otherwise conduct themselves in a manner that does not interfere with Design-Builder’s, Subcontractor’s or equipment supplier’s activities or operations. 7.2.3 Design-Builder shall provide to Owner a Performance Test report (excluding results from air emissions testing), including all applicable test data, calculations and certificates indicating the results of the Performance Tests and, within five (5) business days of Owner’s receipt of such results, Owner, Independent Engineer and Design-Builder will jointly inspect such Work and review the results of the Performance Tests to verify that the Performance Guarantee Criteria have been met. If Owner or Independent Engineer reasonably determines that the Performance Guarantee Criteria have not been met, Owner shall notify Design-Builder the reasons why Owner determined that the Performance Guarantee Criteria have not been met and Design-Builder shall promptly take such action or perform such additional work as will achieve the Performance Guarantee Criteria and shall issue to the Owner another notice in accordance with Section 7.2.2; provided however that if the notice relates to a retest, the notice may be provided no less than two (2) business days prior to the Performance Tests. Such procedure shall be repeated as necessary until Owner and Independent Engineer verifies that the Performance Guarantee Criteria have been met. 7.2.4 If Owner, for whatever reason, prevents Design-Builder from demonstrating the Performance Guarantee Criteria within thirty (30) Days of Design-Builder’s notice that the Plant is ready for Performance Testing, then Design-Builder shall be excused from demonstrating compliance with the Performance Guarantee Criteria during such period of time that Design-Builder is prevented from demonstrating compliance with the Performance Guarantee Criteria; provided however that Design-Builder will be deemed to have fulfilled all of its obligations to demonstrate that the Plant meets the Performance Guarantee Criteria should such period of time during which Design-Builder is prevented from demonstrating the Performance Criteria exceed thirty (30) Days or extend beyond the Final Completion Date.

  • Commencement and Completion The Work shall commence on _______________, 20__ and shall be complete in accordance with this Agreement without delay on ______________, 20__. The term “day”, used throughout this Agreement, refers to calendar days. Contractor shall not be entitled to any additional compensation for any Permitted Delays. If this Agreement is not signed and returned to the Owner before any work commences, this Agreement will be considered as accepted as presented to the Contractor.

  • Hearing Tests Audiometric tests should be conducted within two months of a person commencing employment, and thereafter at intervals of two years.

  • Production Phase contract period in which the Development and the Production are to be performed.

  • Phase 2 Phase 2 is expected to consist of Member Nodes and a select number of Nodes operated by non-Members. The non-Member Nodes will be required to comply with Node hosting terms as set forth by the Council, which may be amended from time to time (the “General Node Terms”).

  • Acceptance Tests 11.1 If the Contract provides acceptance tests for Goods and/or the result of Services after their completion and/or delivery to the Purchaser, the acceptance shall only be considered as definitive when such tests have demonstrated the compliance of the Goods and/or the result of the Services to the requirements in the Contract. 11.2 Where the Contract provides for an acceptance procedure in the presence of both parties, at the successful completion of such procedure, the Purchaser shall issue the Supplier with an acceptance certificate which shall authorise the Supplier to invoice the Purchaser for any payment due on such acceptance. 11.3 The Purchaser shall at its discretion be entitled to issue and acceptancecertificate with reserves. The Supplier shall be obliged to remedy any non-conformities within the period set out in the acceptance certificate. Any payment which would otherwise have been due on acceptance may be withheld by the Purchaser in whole or part until the non- conformities underlying the reserves have been remedied.

  • Performance Tests Contractor shall perform Performance Tests in accordance with Section 11.2 of the Agreement and Attachment S.

  • Random Testing Notwithstanding any provisions of the Collective Agreement or any special agreements appended thereto, section 4.6 of the Canadian Model will not be applied by agreement. If applied to a worker dispatched by the Union, it will be applied or deemed to be applied unilaterally by the Employer. The Union retains the right to grieve the legality of any imposition of random testing in accordance with the Grievance Procedure set out in this Collective Agreement.

  • DATE OF COMMENCEMENT AND SUBSTANTIAL COMPLETION § 3.1 The date of commencement of the Work shall be: § 3.2 The Contract Time shall be measured from the date of commencement of the Work.

Draft better contracts in just 5 minutes Get the weekly Law Insider newsletter packed with expert videos, webinars, ebooks, and more!