Emergency Repairs a) The landlord must post and maintain in a conspicuous place on the residential property, or give to the tenant in writing, the name and telephone number of the designated contact person for emergency repairs. b) If emergency repairs are required, the tenant must make at least two attempts to telephone the designated contact person, and then give the landlord reasonable time to complete the repairs. c) If the emergency repairs are still required, the tenant may undertake the repairs, and claim reimbursement from the landlord, provided a statement of account and receipts are given to the landlord. If the landlord does not reimburse the tenant as required, the tenant may deduct the cost from rent. The landlord may take over completion of the emergency repairs at any time. d) Emergency repairs must be urgent and necessary for the health and safety of persons or preservation or use of the residential property and are limited to repairing i) major leaks in pipes or the roof,
Emergency Generator 1) During the Term as it applies to the 9449 Expansion Space, as extended from time to time, Tenant shall have the right to install a supplemental emergency generator (the “Generator”) to provide emergency additional electrical capacity to the 9449 Building. The Generator shall be placed at a location at the 9449 Building designated by Tenant and reasonably approved by Landlord. Notwithstanding the foregoing, Tenant’s right to install the Generator shall be subject to: (i) Landlord’s reasonable approval of the manner in which the Generator is installed, the manner in which any cables are run to and from the Generator to the Premises and the measures that will be taken to eliminate any vibrations or sound disturbances from the operation of the Generator; and (ii) the covenants, conditions and restrictions of record applicable to the Project, architectural review and any necessary approval by the local municipality and county governments or agencies having authority and jurisdiction over such matters. Landlord shall have the right to require Tenant to provide a reasonably acceptable enclosure (e.g. wood fencing and landscaping) to hide or disguise the existence of the Generator and to minimize any adverse effect that the installation of the Generator may have on the appearance of the 9449 Building and Project. Tenant shall be solely responsible for obtaining all necessary governmental and regulatory permits and approvals and for the cost of installing, operating, maintaining, repairing and removing the Generator. Tenant shall also be responsible for the cost of all utilities consumed and utility connections required in the operation of the Generator. 2) Tenant shall be responsible for assuring that the installation, maintenance, repair, operation and removal of the Generator does not damage the 9449 Building or Project and Tenant shall be responsible for any damages caused thereby. For avoidance of doubt, the installation, maintenance, operation, repair or removal of the Generator shall be subject to the indemnity provisions set forth in Section 10.3 of the Lease. 3) Tenant shall be responsible for the installation, operation, repair, cleanliness, maintenance and removal of the Generator and appurtenances, all of which shall remain the personal property of Tenant and shall be removed by Tenant at its own expense as of the 9449 Extended Expiration Date or any earlier expiration or termination of Tenant’s right to possession of the 9449 Expansion Space in accordance with the Lease and this Amendment. Tenant shall repair any damage caused by such removal, including the patching of any holes to match, as closely as possible, the color surrounding the area where the Generator and appurtenances were attached. Such maintenance and operation shall be performed in a manner to avoid any unreasonable interference with any other tenants or Landlord. Tenant agrees to maintain the Generator, including without limitation, any enclosure installed around the Generator, in good condition and repair. Tenant shall be responsible for performing any maintenance and improvements to any enclosure surrounding the Generator so as to keep such enclosure in good condition. 4) Tenant, subject to the reasonable rules and regulations enacted by Landlord, shall have unlimited access to the Generator and its surrounding area for the purpose of installing, operating, repairing, maintaining, using and removing the Generator. 5) Tenant shall only test the Generator before or after normal business hours. 6) Notwithstanding anything in this Amendment or the Lease to the contrary, Tenant may use the Generator for its intended purpose as and when needed (as reasonably determined by Tenant), without any restriction or hindrance from Landlord or any other tenant, subject only to applicable Laws and unreasonable disturbances to other tenants in the Project.
Emergency Situation In the event of an emergency situation beyond our reasonable control, such as an "act of God," war, fire, or natural disaster, services involving your account could be available only in a modified or reduced form or could be entirely unavailable. Unless expressly prohibited by applicable law, you agree that we will have no liability to you for such modification, reduction, or unavailability of services caused by an emergency situation.
Emergency Room Services This plan covers services received in a hospital emergency room when needed to stabilize or initiate treatment in an emergency. If your condition needs immediate or urgent, but non-emergency care, contact your PCP or use an urgent care center. This plan covers bandages, crutches, canes, collars, and other supplies incidental to your treatment in the emergency room as part of our allowance for the emergency room services. Additional services provided in the emergency room such as radiology or physician consultations are covered separately from emergency room services and may require additional copayments. The amount you pay is based on the type of service being rendered. Follow-up care services, such as suture removal, fracture care or wound care, received at the emergency room will require an additional emergency room copayment. Follow- up care services can be obtained from your primary care provider or a specialist. See Dental Services in Section 3 for information regarding emergency dental care services.
Emergency Operations 6:01 In the event of an emergency which could endanger the health or safety of the public, employees shall unite to meet the emergency and shall, until the danger has been brought under control, perform such duties as may be required of them regardless of their occupation.
Emergency Closings In the event a student day or teacher duty day is lost because of an emergency closing, the teacher shall perform duties on that day (unless hazardous conditions prohibit) or other such day in lieu thereof as the School Board or its designated representative shall determine, if any.
Emergency Calls IP Phones need an additional power supply to operate. In the event of a power failure it is your responsibility to ensure you have the means to make emergency calls. In accordance with paragraph 13.2, we will not be liable for any loss or damage (financial or otherwise) where you fail to do so.
Emergency Closing 1. Management shall decide when, if and to what extent State facilities shall remain open or closed during emergencies, such as adverse weather conditions, acts of God, equipment breakdown, inoperable bathroom facilities, extreme office temperatures, etc. 2. The State shall designate one (1) person in each district area who will be responsible to call the Secretary of Administration or his/her designee if office, weather or other conditions exist which suggest closing is appropriate. 3. In facilities that must remain in operation despite emergency conditions, continued operations with a reduced work force may be authorized. In such instances, employees who are authorized to leave work early may do so without loss of pay or benefits. Employees who are required to remain at work shall receive compensatory time at straight time rates. 4. An employee who is unable to report to work due to weather or other emergency conditions shall have the absence charged against accumulated compensatory time or annual leave, in that order. 5. If management authorizes the complete closing of a State office or facility for emergency reasons, employees who leave the workplace shall receive their regular pay for time they are out of the closed office. 6. Employees required by management to work during complete emergency closings under (5) above, shall receive hourly pay at straight time rates for the hours so worked. This payment will be in addition to the employee’s regular pay.
Emergency Overtime In the event of an emergency as defined in Section 13.15 notwithstanding the terms of this Article, the Agency Head or designee may assign someone to temporarily meet the emergency requirements, regardless of the overtime distribution.
Emergency Closure Where there is a temporary closure as a result of an immediate emergency or a planned temporary closure due to renovations, repairs, or moves, the Employer will: a) First offer to the affected employees the choice of taking either a vacation day or an unpaid leave of absence with no loss of seniority or benefits; thereafter, at the Employer's discretion, one of the following: b) Reassign staff to another location; c) Reschedule the lost hours within two (2) pay periods; or d) Decide not to do either (b) or (c), in which case employees shall still be paid for their regularly scheduled hours which they did not work as a result of the temporary layoff.