FS Characteristics Sample Clauses

FS Characteristics. The physical and chemical characteristics of Septage are summarized in the Table below (U.S. EPA (1984)). Constituent (all units but for pH are in mg/l) Average Range Biochemical Oxygen Demand 6,480 440 - 78,600 Chemical Oxygen Demand 31,900 1,500 - 703,000 Total solids 34,106 1,132 - 130,745 Total Volatile Solids 23,100 353 - 71,402 Total Suspended Solids 12,862 310 - 93,378 Volatile Suspended Solids 9,027 95 - 51,500 Total Kjeldahal Nitrogen 588 66 - 1,060 Xxxxxxx-Xxxxxxxx 00 0 - 000 Xxxxx Xxxxxxxxxx 210 20 - 760 Alkalinity 970 522 - 4,190 Grease 5,600 208 - 23,368 pH - 1.5 – 12.6 Note: Similar parameters have be adopted in the Advisory developed MouD, Jan 2013 and CPHEEO Sludge characteristics mentioned in the FSM Book by Xxxxx Xxxxxxx and paper published by Xxxxxxx, 1996. Parameter Type “A” high strength Type “B” low strength Example Public toilet or bucket latrine sludge Septage Characterization Highly concentrated, mostly fresh FS; stored for days or weeks only FS of low concentration; usually stored for several years; more stabilized than Type “A” COD (mg/L) 20-50,000 <15,000 COD/BOD 5:1 to 10:1 5:1 to 10:1 NH4-N (mg/L) 2-5,000 <1000 TS (%) ≥ 3.5 % < 3 % SS (mg/L) ≥30,000 7000 (approx) Helminth Eggs (unit/ml) 20-60,000 4000 (approx) The Concessionaire is responsible for ensuring compliance with the treatment and discharge norms in order to reuse treated wastes as a fertilizer or soil conditioner in agriculture. Parameter Concentration not to exceed (mg/kg) dry basis, except for pH and carbon to nitrogen ratio) Arsenic 10 Cadmium 5 Chromium 50 Copper 300 Lead 100 Mercury 0.15 Nickel 50 Zinc 1000 C/N ratio 20-40 pH 5.5-8.5 Compost Quality (FCO) as per SWM Rules, 2016 and Dept. of Fertilizers. Dewatered septage to be used as a fertilizer it should satisfy the following criteria of Class A Bio-solids of US EPA (CEPT, 2015). • Faecal coliform density < 1000 MPN/g total dry solids • Salmonella sp. Density < 3 MPN/ 4 g of total dry solids • Helminth egg concentration of < 1/g total solids (WHO, 2006) • E coli of 1000/g total solids (WHO, 2006). Accordingly, the Concessionaire has to adhere to the above KPIs and for any deviation, the Authority is entitled to levy and collect the Damages at Rs.5000 (Rupees five thousand) per month per FSTP. SCHEDULE D (See Clause 9.1) PERFORMANCE SECURITY (To be submitted on Non-Judicial stamp paper of appropriate value purchased in the name of the issuing bank) To: The Managing Director, Swachha Andhra Corporation, Vijayaw...
AutoNDA by SimpleDocs

Related to FS Characteristics

  • Characteristics The Initial Contracts have the following characteristics: (i) all the Contracts are secured by Motorcycles; (ii) no Initial Contract has a remaining maturity of more than 84 months; and (iii) the final scheduled payment on the Initial Contract with the latest maturity is due not later than June 2014. Approximately 77.89% of the Principal Balance of the Initial Contracts as of the Initial Cutoff Date is attributable to loans for purchases of new Motorcycles and approximately 22.11% is attributable to loans for purchases of used Motorcycles. No Initial Contract was originated after the Initial Cutoff Date. No Initial Contract has a Contract Rate less than 3.989%. The last scheduled payment date of the Contracts (including any Subsequent Contracts) is due not later than September 2014. Approximately 98.98% of the Principal Balance of the Initial Contracts as of the Initial Cutoff Date is attributable to loans to purchase Motorcycles manufactured by Harley-Davidson or Buell and approximately 1.02% of the Principal Balance of the Initial Contracts as of the Initial Cutoff Date is attributable to loans to purchase Motorcycles not manufactured by Harley-Davidson or Buell.

  • Additional Service Characteristics 3.12 The technical specification of the Bitstream 2a Service is set out in Appendix B.

  • Physical File Characteristics 6.2.1 The Optional Daily Usage File will be distributed to <<customer_name>> via an agreed medium with CONNECT:Direct being the preferred transport method. The Daily Usage Feed will be a variable block format (2476) with an LRECL of 2472. The data on the Daily Usage Feed will be in a non-compacted EMI format (175 byte format plus modules). It will be created on a daily basis (Monday through Friday except holidays). Details such as dataset name and delivery schedule will be addressed during negotiations of the distribution medium. There will be a maximum of one dataset per workday per OCN.

  • Technical Characteristics The Participating Generator has provided to the CAISO in Schedule 1 the required information regarding the capacity and operating characteristics of each of the Generating Units listed in that schedule. Pursuant to Sections 8.9 and 8.10 of the CAISO Tariff, the CAISO may verify, inspect and test the capacity and operating characteristics provided in Schedule 1.

  • Characteristics of the level (a) A person employed as a Social and community services employee level 6 will operate under limited direction from senior employees or management and undertake a range of functions for which operational policies, practices and guidelines may need to be developed.

  • ODUF Physical File Characteristics 6.2.1 ODUF will be distributed to Image Access via Secure File Transfer Protocol (FTP). The ODUF feed will be a variable block format. The data on the ODUF feed will be in a non-compacted EMI format (one hundred seventy-five (175) byte format plus modules). It will be created on a daily basis Monday through Friday except holidays. Details such as dataset name and delivery schedule will be addressed during negotiations of the distribution medium. There will be a maximum of one (1) dataset per workday per OCN. If BellSouth determines the Secure FTP Mailbox is nearing capacity levels, BellSouth may move the customer to CONNECT:Direct file delivery.

  • CHARACTERISTICS OF THE ACADEMY 10) The characteristics of the Academy set down in Section 1(6) of the Academies Act 2010, are that:

  • Personal Characteristics A. Dependability/Attendance E. Adapts readily to new situations, demands and emergencies.

  • Title and Characteristics of Property Seller, as of the date of execution of this Agreement, owns the Property in fee simple and has marketable and good title of public record and, in fact, the Property at Closing shall have the title status as described in Section VIII of this Agreement.

  • REVIEW OF THE FRAMEWORK PRICES LOTS 1 – 10

Time is Money Join Law Insider Premium to draft better contracts faster.