GPA Standard 2261 Sample Clauses

GPA Standard 2261. All samples shall be analyzed by SABINE to determine the molar fraction of the hydrocarbon and other components in the sample by gas chromatography using a mutually agreed method in accordance with GPA Standard 2261 - Method of Analysis for Gas and Similar Gaseous Mixtures by Gas Chromatography, current as of January 1, 1990 and as periodically updated or as otherwise mutually agreed by the Parties. If better standards for analysis are subsequently adopted by GPA or other recognized competent impartial authority, upon mutual agreement of Customer and SABINE, they shall be substituted for the standard then in use, but such substitution shall not take place retroactively. A calibration of the chromatograph or other analytical instrument used shall be performed by SABINE immediately prior to the analysis of the sample of LNG delivered. SABINE shall give advance notice to Customer of the time SABINE intends to conduct a calibration thereof, and Customer shall have the right to have a representative present at each such calibration; provided, however, SABINE will not be obligated to defer or reschedule any calibration in order to permit the representative of Customer to be present.
AutoNDA by SimpleDocs
GPA Standard 2261. All samples shall be analyzed by Project Co to determine the molar fraction of the hydrocarbon and other components in the sample by gas chromatography using a mutually agreed method in accordance with GPA Standard 2261 - Method of Analysis for Gas and Similar Gaseous Mixtures by Gas Chromatography, current as of January 1st, 1990 and as periodically updated or as otherwise mutually agreed by the Parties. If better standards for analysis are subsequently adopted by GPA or other recognized competent impartial authority, upon mutual agreement of the Transporter and Project Co, they shall be substituted for the standard then in use, but such substitution shall not take place retroactively. A calibration of the chromatograph or other analytical instrument used shall be performed by Project Co immediately prior to the analysis of the sample of LNG delivered. Project Co shall give advance notice to the Transporter of the time Project Co intends to conduct a calibration thereof, and the Transporter shall have the right to have a representative present at each such calibration; provided, however, Project Co will not be obligated to defer or reschedule any calibration in order to permit the representative of the Transporter to be present.

Related to GPA Standard 2261

  • Design Criteria and Standards All Projects/Services shall be performed in accordance with instructions, criteria and standards set forth by the Director.

  • Power Factor Design Criteria Developer shall design the Large Generating Facility to maintain an effective power delivery at demonstrated maximum net capability at the Point of Interconnection at a power factor within the range established by the Connecting Transmission Owner on a comparable basis, until NYISO has established different requirements that apply to all generators in the New York Control Area on a comparable basis. The Developer shall design and maintain the plant auxiliary systems to operate safely throughout the entire real and reactive power design range. The Connecting Transmission Owner shall not unreasonably restrict or condition the reactive power production or absorption of the Large Generating Facility in accordance with Good Utility Practice.

  • Service Level Standards In addition to all other requirements in this Agreement, and in accordance with the Best Claims Practices & Estimating Guidelines, Vendor shall use reasonable and good faith efforts to meet the Service Level Standards set forth below.

  • Switching and Tagging Rules Each Party shall provide the other Parties a copy of its switching and tagging rules that are applicable to the other Parties’ activities. Such switching and tagging rules shall be developed on a non-discriminatory basis. The Parties shall comply with applicable switching and tagging rules, as amended from time to time, in obtaining clearances for work or for switching operations on equipment.

  • Technical Standards The Generation System shall be installed and operated by the Interconnection Customer consistent with the requirements of this Agreement; the Technical Requirements; the applicable requirements located in the National Electrical Code (NEC); the applicable standards published by the American National Standards Institute (ANSI) and the Institute of Electrical and Electronic Engineers (IEEE); and local building and other applicable ordinances in effect at the time of the installation of the Generation System.

  • Applicable Standards The requirements and guidelines of NERC, the Applicable Regional Entity, and the Control Area in which the Customer Facility is electrically located; the PJM Manuals; and Applicable Technical Requirements and Standards.

  • Meets Standard The school materially complies with applicable laws, rules, regulations and provisions of the charter contract relating to financial reporting requirements, including but not limited to: • Complete and on-time submission of financial reports, including annual budget, revised budgets (if applicable), periodic financial reports as required by the authorizer and any reporting requirements if the board contracts with an Education Service Provider (ESP) • On-time submission and completion of the annual independent audit and corrective action plans, if applicable • No charging of tuition • Adequate management and financial controls • All reporting requirements related to the use of public funds

  • Power Factor Design Criteria (Reactive Power A wind generating plant shall maintain a power factor within the range of 0.95 leading to 0.95 lagging, measured at the Point of Interconnection as defined in this LGIA, if the ISO’s System Reliability Impact Study shows that such a requirement is necessary to ensure safety or reliability. The power factor range standards can be met using, for example without limitation, power electronics designed to supply this level of reactive capability (taking into account any limitations due to voltage level, real power output, etc.) or fixed and switched capacitors if agreed to by the Connecting Transmission Owner for the Transmission District to which the wind generating plant will be interconnected, or a combination of the two. The Developer shall not disable power factor equipment while the wind plant is in operation. Wind plants shall also be able to provide sufficient dynamic voltage support in lieu of the power system stabilizer and automatic voltage regulation at the generator excitation system if the System Reliability Impact Study shows this to be required for system safety or reliability.

  • Maintenance Manual No later than 60 (sixty) days prior to the Project Completion Date, the Contractor shall, in consultation with the Authority’s Engineer, evolve a maintenance manual (the “Maintenance Manual”) for the regular and preventive maintenance of the Project Highway in conformity with the Specifications and Standards, safety requirements and Good Industry Practice, and shall provide 5 (five) copies thereof to the Authority’s Engineer. The Authority’s Engineer shall review the Maintenance Manual within 15 (fifteen) days of its receipt and communicate its comments to the Contractor for necessary modifications, if any.

  • Minimum Standard of Treatment 1. Each Party shall accord to a covered investment treatment in accordance with the customary international law minimum standard of treatment of aliens, including fair and equitable treatment and full protection and security. 2. The concepts of “fair and equitable treatment” and “full protection and security” in paragraph 1 do not require treatment in addition to or beyond that which is required by the customary international law minimum standard of treatment of aliens. 3. A breach of another provision of this Agreement, or of a separate international agreement, does not establish that there has been a breach of this Article.

Draft better contracts in just 5 minutes Get the weekly Law Insider newsletter packed with expert videos, webinars, ebooks, and more!