Common use of Heated equipment Clause in Contracts

Heated equipment. It shall be verified that the difference between the inside temperature of the equipment and the outside temperature which governs the class to which the equipment belongs as prescribed in this annex (a difference of 22 K in the case of class A and of 32 K in the case of class B) can be achieved and be maintained for not less than 12 hours. If the results are acceptable, the equipment may be kept in service as heated equipment of its initial class for a further period of not more than three years.

Appears in 6 contracts

Samples: www.unece.org, www.vestnesis.lv, digitallibrary.un.org

AutoNDA by SimpleDocs

Heated equipment. It shall be verified that the difference between the inside temperature of the equipment and the outside temperature which governs the class to which the equipment belongs as prescribed in this annex (a difference of 22 K in the case of class A and of 32 K in the case of class B) can be achieved and be maintained for not less than 12 hours. If the results are acceptablefavourable, the equipment may be kept in service as heated equipment of its initial class for a further period of not more than three years.

Appears in 2 contracts

Samples: Agreement, Agreement

Heated equipment. It shall be verified that the difference between the inside temperature of the equipment and the outside temperature which governs the class to which the equipment belongs as prescribed in this annex (a difference of 22 K 22o C in the case of class A and of 32 K 32o C in the case of class B) can be achieved and be maintained for not less than 12 hours. If the results are acceptablefavourable, the equipment may be kept in service as heated equipment of its initial class for a further period of not more than three years.

Appears in 1 contract

Samples: www.riigiteataja.ee

AutoNDA by SimpleDocs

Heated equipment. It shall be verified that the difference between the inside temperature of the equipment and the outside temperature which governs the class to which the equipment belongs as prescribed in this annex (a difference of 22 K °C in the case of class A and of 32 K °C in the case of class B) can be achieved and be maintained for not less than 12 hours. If the results are acceptablefavourable, the equipment may be kept in service as heated equipment of its initial class for a further period of not more than three years.

Appears in 1 contract

Samples: Agreement

Time is Money Join Law Insider Premium to draft better contracts faster.