Insulation Materials and Installation Sample Clauses

Insulation Materials and Installation. All piping shall be insulated as required to meet OSHA requirements. All piping operating above 140oF shall be insulated with calcium silicate molded insulation, mineral fiber insulation, or high density fiberglass. Equipment and ductwork operating at elevated temperatures shall be insulated with calcium silicate block or mineral fiber block insulation. For equipment operating above 140oF where retention of heat is not necessary for proper and efficient operation, insulation or other measures such as guards will be provided for personnel protection only. Mineral fiber block insulation for use on equipment surfaces shall be in accordance with ASTM C612, Class 3, and have a density of 8 to 12 pcf. Mineral fiber blanket insulation shall not be used, except for selected applications for practicality. Insulating cements shall be mineral fiber thermal insulating cements and will conform with ASTM C195. Antisweat insulation shall be flexible elastomeric cellular thermal insulation. Above grade indoor water piping will be provided with -------------------------------------------------------------------------------- EPC - Exhibit B TENASKA GEORGIA GENERATION PROJECT --------------- Page 78 of 132 -------------------------------------------------------------------------------- -------------------------------------------------------------------------------- antisweat insulation. Outdoor antisweat insulation will be protected with paint or lagging in accordance with the manufacturer's recommendations. Piping and small diameter cylindrical equipment insulation shall be hollow cylindrical shapes split in half lengthwise, or curved segments. Large diameter cylindrical equipment and other items of equipment shall be insulated with block or scored block insulation as required to obtain a close fit to the contour. Pipe fittings and accessories shall be insulated using either molded insulation or by insulation fabricated from straight pipe insulation segments. Weatherproof protective coatings shall be applied in accordance with the manufacturer's recommendations. Insulation shall be securely tied and laced in place with stainless steel wire. Blocks shall be reinforced on the exterior face with expanded metal, if necessary, to prevent sagging or cutting of insulation by lacing wire. Studs used for attachment of insulation shall be Xxxxxx stainless steel studs in lengths suitable for the insulation thickness. Studs shall be spaced on centers not exceeding 12 inches. Washers fo...
AutoNDA by SimpleDocs

Related to Insulation Materials and Installation

  • Communications Equipment Members of the board of directors or any committee thereof may participate in and act at any meeting of such board or committee through the use of a conference telephone or other communications equipment by means of which all persons participating in the meeting can hear each other, and participation in the meeting pursuant to this section shall constitute presence in person at the meeting.

  • Materials and Equipment Except for materials or Equipment to be supplied by Subcontractors identified on part B of Schedule 7, whenever materials or Equipment are specified or described in this Contract (including the Specifications) by using the name of a proprietary item or the name of a particular supplier, the naming of the item is intended to establish the type, function and quality required, and substitute materials or Equipment may nonetheless be used, provided that such materials or Equipment are equivalent or equal to that named. If the Vendor wishes to furnish or use a substitute item of material or Equipment, the Vendor must first certify that the proposed substitute will perform at least as well the functions and achieve the results called for by this Contract, will be substantially similar or of equal substance to that specified and be suited for the same use as that specified. The Owner may require the Vendor to furnish, at the Vendor's expense, additional data about the proposed substitute as required to evaluate the substitution. For Major Portions of the Work, or materials or Equipment listed on part B of Schedule 7, the Vendor must first receive prior written approval of the Owner for any substitution. The Owner will be allowed a reasonable time within which to evaluate each proposed substitute. Notwithstanding the foregoing, with respect to PCS Products, prior to the shipment of such PCS Products pursuant to the terms of this Contract, the Vendor may at any time without notice to or consent of the Owner make changes in a Vendor PCS Product furnished pursuant to this Contract, or modify the drawings and published specifications relating thereto, or substitute Products of similar or later design to fulfill its obligations under this Contract or otherwise fill an order, provided that the changes, modifications or substitutions will in no way affect or otherwise impact upon the form, fit, or function of an ordered Product pursuant to and in accordance with the applicable Specifications. With respect to changes, modifications and substitutions which do in fact affect the form, fit, or function of an ordered Product pursuant to and in accordance with the Specifications, the Vendor must notify the Owner in writing at least thirty (30) days prior to the effective dates of any such changes, modifications or substitutions. In the event that any such change, modification or substitution is not desired by the Owner, the Owner will notify the Vendor within thirty (30) days from the date of notice and the Vendor will not furnish any such changed Products to the Owner on any orders in process at the time the Owner is so notified; provided that nothing contained herein will otherwise modify the Vendor's obligations under the terms of this Contract.

  • DELIVERY AND INSTALLATION Lessee shall be responsible for payment of all transportation, packing, installation, testing and other charges associated with the delivery, installation or use of any Equipment which are not included in the Agreement with respect to such Equipment.

  • Maintenance Repairs Utility Installations Trade Fixtures and Alterations 7.1 Lessee's Obligations.

  • Underground Tanks If underground or other storage tanks storing Hazardous Materials located on the Premises or the Project are used by Tenant or are hereafter placed on the Premises or the Project by Tenant, Tenant shall install, use, monitor, operate, maintain, upgrade and manage such storage tanks, maintain appropriate records, obtain and maintain appropriate insurance, implement reporting procedures, properly close any underground storage tanks, and take or cause to be taken all other actions necessary or required under applicable state and federal Legal Requirements, as such now exists or may hereafter be adopted or amended in connection with the installation, use, maintenance, management, operation, upgrading and closure of such storage tanks.

  • Removal of Improvements Except as otherwise expressly agreed to by Lessor and Lessee, Lessee shall have the right to remove all Tank Farm Assets and other improvements, fixtures, equipment, materials, supplies and personal property installed by Lessee from the Premises upon the termination or expiration of this Lease, but in no event later than the date that is 120 days following the expiration or termination of this Lease (the “Removal Date”) and Lessor shall provide Lessee with access to the Premises at reasonable times until expiration of the Removal Date for the purpose of removing such items. Lessee shall provide Lessor with written notice of its election to remove the Tank Farm Assets and other improvements, fixtures, equipment, materials, supplies and personal property from the Premises at least 60 days prior to the expiration of the Lease. If Lessee elects to remove the Tank Farm Assets and Improvements from the Premises after such removal Lessee shall restore any damage to the Premises and clean the Premises so as to eliminate therefrom any accumulation (other than any de minimis and non-hazardous accumulation) of foreign substances, materials, or debris, in addition to any Environmental Cleanup that may be required under Article 10. Lessee shall pay Lessor pro rata Rent (based on the amount of Rent applicable during the last month prior to the termination or expiration) through the date of Lessee’s complete removal of all such items. During the period of such removal and clean-up, all terms and conditions of this Lease, including, the indemnity and insurance provisions shall continue in full force and effect. If Lessee elects not to remove all of the Tank Farm Assets and Improvements from the Premises on or before the Removal Date, and provided that such facilities are in good working condition at the expiration of the Term (ordinary wear and tear excepted) then, such Tank Farm Assets and Improvements shall be deemed permanently abandoned to Lessor’s sole ownership, and Lessor may remove and dispose of such facilities in any manner which Lessor may deem appropriate, without any liability whatsoever to Lessee. If Lessee elects not to remove all of the Tank Farm Assets and Improvements from the Premises on or before the Removal Date and such facilities are not in good working condition at the expiration of the term (ordinary wear and tear excepted), or Lessee fails to so remove any or all of the Tank Farm Assets and Improvements from the Premises before the Removal Date, then, in addition to all rights and remedies available at law or in equity, without any prior notice, Lessor may (but shall be under no obligation), at Lessor’s option, deem such Tank Farm Assets and Improvements to be permanently abandoned to Lessor’s sole ownership, and Lessor may remove and dispose of such facilities in any manner which Lessor may deem appropriate, without any liability whatsoever to Lessee, and Lessee shall reimburse Lessor for all costs of such removal and disposal upon demand from Lessor. If requested by Lessor, Lessee shall execute any and all documents necessary to evidence that title to the Tank Farm Assets and Improvements that Lessee does not remove by the Removal Date is in Lessor and to extinguish and remove any cloud or potential cloud on the title to the Premises and/or such facilities created by Lessee.

  • Utility Installations Trade Fixtures Alterations 8.3.1 The term “Utility Installations” refers to all floor and window coverings, air and/or vacuum lines, power panels, electrical distribution, security and fire protection systems, communication cabling, lighting fixtures, HVAC equipment, plumbing, and fencing in or on the Premises. The term “

  • HAZARDOUS MATERIALS DISCLOSURES 7.1 Does your company handle an aggregate of at least 500 pounds, 55 gallons or 200 cubic feet of hazardous material at any given time? Yes ( ) No ( )

  • Installation Tenant may install and use Tenant's Lines and make connections and disconnections at the terminal blocks as described above, provided Tenant shall: (i) obtain Landlord's prior written approval of all aspects thereof, (ii) use an experienced and qualified contractor designated or approved in writing in advance by Landlord (whom Landlord may require to enter an access and indemnity agreement on Landlord's then standard form of agreement therefor), (iii) comply with such inside wire standards as Landlord may adopt from time to time, and all other provisions of this Lease, including Paragraph 8 respecting alterations, and the Building rules respecting access to the wire closets, (iv) not install Lines in the same sleeve, chaseway or other enclosure in close proximity with electrical wire, and not install PVC-coated Lines under any circumstances, (v) thoroughly test any riser Lines to which Tenant intends to connect any Lines to ensure that such riser Lines are available and are not then connected to or used for telephone, data transmission or any other purpose by any other party (whether or not Landlord has previously approved such connections), and not connect to any such unavailable or connected riser Lines, and (vi) not connect any equipment to the Lines which may create an electromagnetic field exceeding the normal insulation ratings of ordinary twisted pair riser cable or cause radiation higher than normal background radiation, unless the Lines therefor (including riser Lines) are appropriately insulated to prevent such excessive electromagnetic fields or radiation (and such insulation shall not be provided by the use of additional unused twisted pair Lines). As a condition to permitting installation of new Lines, Landlord may require that Tenant remove any existing Lines located in or serving the Premises.

  • Maintenance Repairs and Alterations 6.01 Tenant's Obligations to Repair ------------------------------ Tenant shall at its sole cost and expense, maintain in clean and safe condition, and make all repairs and replacements to the Premises and every part thereof, structural and non-structural, so as to keep, maintain and preserve the Premises in first class condition and repair, including, without limitation, the roof, the foundation, the heating, ventilation and air conditioning system ("HVAC"), elevators, if any, all plumbing and sewage facilities, fire sprinklers, electrical and lighting facilities, systems, appliances, and equipment within the Premises, fixtures, interior and exterior walls, floors, ceilings, windows, doors, entrances, all interior and exterior glass (including plate glass), and skylights located within the Premises, and all sidewalks, service areas, parking areas and landscaping comprising part of the Premises. All repairs and replacements required to be made by Tenant shall be made promptly with new materials of like kind and quality to those used in the original construction of the Premises. If the repair or replacement work affects the structural parts of the Premises, or if the estimated cost of any item or repair or replacement exceeds $10,000, then Tenant shall first obtain Landlord's written approval of the scope of work, plans therefor, and materials to be used. Any such work shall be performed by Landlord's contractor or by such contractor as Tenant may choose from an approved list to be submitted by Landlord. Landlord shall have the right to make any repairs or replacements which are not promptly made by Tenant and charge Tenant, as Additional Rent, for the cost thereof together with interest thereon at the Agreed Rate from the date of payment thereof by Landlord. Without limiting any of Tenant's obligations hereunder, during the Lease Term Tenant, at its expense, shall obtain and keep in force an HVAC service contract and a roof maintenance program satisfactory to Landlord. Tenant hereby waives the benefit of any statute now or hereafter in effect which would otherwise afford Tenant the right to make repairs at Landlord's expense or to terminate this Lease because of Landlord's failure to keep the Premises in good condition, order and repair. Tenant specifically waives all rights it may have under Sections 1932(1), 1941 and 1942 of the California Civil Code, and any similar or successor statute or law. Notwithstanding anything to the contrary contained herein, Landlord shall exercise its rights under any guaranties or warranties relating to the original construction of the Premises if the need to make repairs arises due to a defect therein; provided, however, Landlord shall not have any liability or be required to expend any funds if such guaranties or warranties are not honored by the makers hereof.