Common use of Participating TO’s Reliability Network Upgrades Clause in Contracts

Participating TO’s Reliability Network Upgrades. The additions, modifications, and upgrades to the Participating TO’s Transmission System at or beyond the Point of Interconnection, identified in the Interconnection Studies, as identified in Attachment 6, necessary to interconnect the Small Generating Facility safely and reliably to the Participating TO’s Transmission System, which would not have been necessary but for the interconnection of the Small Generating Facility, including additions, modifications, and upgrades necessary to remedy short circuit or stability problems resulting from the interconnection of the Small Generating Facility to the Participating TO’s Transmission System. Participating TO’s Reliability Network Upgrades also include, consistent with Applicable Reliability Standards and Applicable Reliability Council practice, the Participating TO’s facilities necessary to mitigate any adverse impact the Small Generating Facility’s interconnection may have on a path’s Applicable Reliability Council rating. Participating TO’s Reliability Network Upgrades do not include any Participating TO’s Delivery Network Upgrades.

Appears in 3 contracts

Samples: Small Generator Interconnection Agreement, Small Generator Interconnection Agreement, Small Generator Interconnection Agreement (Sgia)

AutoNDA by SimpleDocs

Participating TO’s Reliability Network Upgrades. The additions, modifications, and upgrades to the Participating TO’s Transmission System at or beyond the Point of Interconnection, identified in the Interconnection Studiesinterconnection studies, as identified in Attachment 6, necessary to interconnect the Small Generating Facility safely and reliably to the Participating TO’s Transmission System, which would not have been necessary but for the interconnection of the Small Generating Facility, including additions, modifications, and upgrades necessary to remedy short circuit or stability problems resulting from the interconnection of the Small Generating Facility to the Participating TO’s Transmission System. Participating TO’s Reliability Network Upgrades also include, consistent with Applicable Reliability Standards and Applicable Reliability Council practice, the Participating TO’s facilities necessary to mitigate any adverse impact the Small Generating Facility’s interconnection may have on a path’s Applicable Reliability Council rating. Participating TO’s Reliability Network Upgrades do not include any Participating TO’s Delivery Network Upgrades.

Appears in 1 contract

Samples: Small Generator Interconnection Agreement

AutoNDA by SimpleDocs
Draft better contracts in just 5 minutes Get the weekly Law Insider newsletter packed with expert videos, webinars, ebooks, and more!