Performance and Remuneration Review for Eligible Market Sample Clauses

Performance and Remuneration Review for Eligible Market rated Group 4 and Group 5 Employees (a) Unless you are an Ineligible Market-rated Employee, for eligible Market-rated Group 4 and Group 5 Employees, ANZ will make provision for the 2023/24, 2024/25, 2025/26 and 2026/27 ANZ Financial Years in accordance with this clause. (b) ANZ has the sole discretion to determine your performance rating. Your Performance Assessment will be determined in accordance with ANZ Policy. (c) Subject to (d) to (g) below, ANZ will make provision for the relevant ANZ Financial Year for Market-rated Group 4 and Group 5 Employees effective from 1 October in the relevant ANZ Financial Year (as calculated by reference to your TEC Package for Group 4 Market-rated Employees or Salary for Group 5 Market-rated Employees (as applicable) as at the Data Effective Date of the relevant performance and remuneration review period) as follows: Year Effective Provision 2023 Review for the 2023/24 ANZ Financial Year 1 October 2023 A. An increase to the total TEC Package and Market- rated Salary budget of 4%.
AutoNDA by SimpleDocs

Related to Performance and Remuneration Review for Eligible Market

  • Performance Review Where a performance review of an employee’s performance is carried out, the employee shall be given sufficient opportunity after the interview to read and review the performance review. Provision shall be made on the performance review form for an employee to sign it. The form shall provide for the employee’s signature in two (2) places, one (1) indicating that the employee has read and accepts the performance review, and the other indicating that the employee disagrees with the performance review. The employee shall sign in only one (1) of the places provided. No employee may initiate a grievance regarding the contents of a performance review unless the signature indicates disagreement. An employee shall, upon request, receive a copy of this performance review at the time of signing. An employee’s performance review shall not be changed after an employee has signed it, without the knowledge of the employee, and any such changes shall be subject to the grievance procedure of this Agreement. The employee may respond, in writing, to the performance review. Such response will be attached to the performance review.

  • Compensation Review The compensation of the Executive will be reviewed not less frequently than annually by the board of directors of the Company.

  • Performance Reviews The Employee will be provided with a written performance appraisal at least once per year and said appraisal will be reviewed at which time all aspects of the assessment can be fully discussed.

  • Performance and Salary Review Company will periodically review Executive’s performance on no less than an annual basis. Adjustments to salary or other compensation, if any, will be made by Company in its sole and absolute discretion.

  • SALARY DETERMINATION FOR EMPLOYEES IN ADULT EDUCATION [Not applicable in School District No. 62 (Sooke)]

  • Annual Performance Review The Employee’s performance of his duties under this Agreement shall be reviewed by the Board of Directors or a committee of the Board of Directors at least annually and finalized within thirty (30) days of the receipt of the annual audited financial statements. The Board of Directors or a committee of the Board of Directors shall additionally review the base salary, bonus and benefits provided to the Employee under this Agreement and may, in their discretion, adjust the same, as outlined in Addendum B of this Agreement, provided, however, that Employee’s annual base salary shall not be less than the base salary set forth in Section 4(A) hereof.

  • Performance Pay In accordance with Section 8 of the General Appropriations Act for Fiscal Year 2020-2021, contingent upon the availability of funds and at the Agency Head’s discretion, each agency is authorized to grant merit pay increases based on the employee’s exemplary performance, as evidenced by a performance evaluation conducted pursuant to Rule 60L-35, Florida Administrative Code.

  • Performance Testing 7.2.1 The Design-Builder shall direct and supervise the tests and, if necessary, the retests of the Plant using Design-Builder’s supervisory personnel and the Air Emissions Tester shall conduct the air emissions test, in each case, in accordance with the testing procedures set forth in Exhibit A (the “Performance Tests”), to demonstrate, at a minimum, compliance with the Performance Guarantee Criteria. Owner is responsible for obtaining Air Emissions Tester and for ensuring Air Emissions Tester’s timely performance. Design-Builder shall cooperate with the Air Emissions Tester to facilitate performance of all air emissions tests. Design-Builder shall not be held responsible for the actions of Owner’s employees and third parties involved in the Performance Testing, including but not limited to Air Emissions Tester. 7.2.2 No later than thirty (30) Days prior to the earlier of the Scheduled Substantial Completion Date or Substantial Completion, Design-Builder shall provide to Owner for review a detailed testing plan for the Performance Tests (other than for air emissions). Owner and Design-Builder shall agree upon a testing plan that shall be consistent with the Performance Test Protocol contained in Exhibit A hereto. After such agreement has been reached, Design-Builder shall notify the Owner five (5) business days prior to the date Design-Builder intends to commence the Performance Tests and shall notify the Owner upon commencement of the Performance Tests. Owner and Independent Engineer each have the right to witness all testing, including the Performance Tests and any equipment testing, whether at the Site or at the Subcontractor’s or equipment supplier’s premises during the course of this Agreement. Notwithstanding the foregoing sentence, Owner shall bear the costs of providing a witness to any such testing and all such witnesses shall comply at all times with Design-Builder’s, Subcontractor’s or equipment supplier’s safety and security procedures and other reasonable requirements, and otherwise conduct themselves in a manner that does not interfere with Design-Builder’s, Subcontractor’s or equipment supplier’s activities or operations. 7.2.3 Design-Builder shall provide to Owner a Performance Test report (excluding results from air emissions testing), including all applicable test data, calculations and certificates indicating the results of the Performance Tests and, within five (5) business days of Owner’s receipt of such results, Owner, Independent Engineer and Design-Builder will jointly inspect such Work and review the results of the Performance Tests to verify that the Performance Guarantee Criteria have been met. If Owner or Independent Engineer reasonably determines that the Performance Guarantee Criteria have not been met, Owner shall notify Design-Builder the reasons why Owner determined that the Performance Guarantee Criteria have not been met and Design-Builder shall promptly take such action or perform such additional work as will achieve the Performance Guarantee Criteria and shall issue to the Owner another notice in accordance with Section 7.2.2; provided however that if the notice relates to a retest, the notice may be provided no less than two (2) business days prior to the Performance Tests. Such procedure shall be repeated as necessary until Owner and Independent Engineer verifies that the Performance Guarantee Criteria have been met. 7.2.4 If Owner, for whatever reason, prevents Design-Builder from demonstrating the Performance Guarantee Criteria within thirty (30) Days of Design-Builder’s notice that the Plant is ready for Performance Testing, then Design-Builder shall be excused from demonstrating compliance with the Performance Guarantee Criteria during such period of time that Design-Builder is prevented from demonstrating compliance with the Performance Guarantee Criteria; provided however that Design-Builder will be deemed to have fulfilled all of its obligations to demonstrate that the Plant meets the Performance Guarantee Criteria should such period of time during which Design-Builder is prevented from demonstrating the Performance Criteria exceed thirty (30) Days or extend beyond the Final Completion Date.

  • Performance Tests Contractor shall perform Performance Tests in accordance with Section 11.2 of the Agreement and Attachment S.

  • Performance Bonuses The Executive will be eligible to receive an annual cash bonus at an annualized rate of up to 40% of his base salary, based on the achievement of reasonable individual and Company performance targets to be established by the Company and Parent.

Draft better contracts in just 5 minutes Get the weekly Law Insider newsletter packed with expert videos, webinars, ebooks, and more!