Principal characteristics. Number of layers of glass: Number of layers of interlayer: Thickness category: Nominal thickness of interlayer(s): Special treatment of glass: Nature and type of interlayer(s): Nature and type of plastics coating(s): Nominal thickness of plastics coating(s): Secondary characteristics: Nature of the material (plate, float, sheet glass): Colouring of interlayer (total/partial): Colouring of glass: Colouring of plastics coating(s): Conductors incorporated (yes/no): Opaque obscuration incorporated (yes/no): Remarks: (Principal and secondary characteristics as defined in Annex 10 to Regulation No. 43)
Principal characteristics. Composition of double-glazed units (symmetrical/asymmetrical): .................. Nominal thickness of the gap: .......................................................................... Method of assembly: ......................................................................................... Type of each glazing component as defined in Xxxxxxx 0, 0, 0, 00 xx 00: ....... ...........................................................................................................................
Principal characteristics. Chemical designation of the material: ............................................................................................... Process of manufacture: .................................................................................................................... Nominal thickness:............................................................................................................................ Colouring of the plastic product:....................................................................................................... Nature and type of surface coating: ...................................................................................................
Principal characteristics. Remarks: For laminated glass panes with enhanced mechanical properties with additional symbol /D (yes/no) 1 1 Strike out what does not apply."
Principal characteristics. Remarks: For laminated glass panes with enhanced mechanical properties with additional symbol /D (yes/no) 1 ...................................................................................................................................... 1 Strike out what does not apply."
Principal characteristics. Composition of multiple glazed units (symmetrical/asymmetrical): ................ Nominal thickness of the gap: .......................................................................... Method of assembly: ......................................................................................... Type of each glazing component as defined in Xxxxxxx 0, 0, 0, 00 xx 00: ....... ........................................................................................................................... Documents attached: One form for all panes of a symmetrical multiple glazed unit in accordance with the annex under which the panes have been tested or approved. One form for each different pane of an asymmetrical multiple glazed unit in accordance with the annexes under which these panes have been tested or approved. Remarks: ....................................................................................................................... ...................................................................................................................................... ......................................................................................................................................
Principal characteristics. Chemical designation of the material: The classification of the material by the manufacturer: Process of manufacture: Shape and dimensions: Nominal thickness: Colouring of the rigid plastic material: Nature and type of surface coating: Secondary characteristics: Conductors incorporated (yes/no): Remarks: (Principal and secondary characteristics in accordance with Annex 15 to Regulation No. 43)
Principal characteristics. These specifications are intended to describe the contract design for one inland river crane barge. The principal dimensions of the barge are: Length Overall Beam Overall Molded Depth (@ C.L.) Molded Depth (@ Side) 200’-0”56’-0”10’-6”10’-0” Light Ship Draft 6’-0” Max Draft 6’-6” The following definitions are applicable to phrases and acronyms used throughout this contract: • ABS – American Bureau of Shipping • COR - Contracting Officer’s Representative - a member of the contract management and quality assurance team authorized by the Contracting Officer to perform certain administrative and managerial duties. A copy of the COR’s authority letter is furnished to the Contractor. • GFE – Government Furnished Equipment – Equipment, materials or components furnished by the Government to the Contractor for installation on the vessel. • K.O. - Contracting Officer - A person with the authority to enter into, administer and/or terminate contracts and make related determinations and findings. • MDC – Acronym for the Marine Design Center. • QC - Quality Control - Quality Control is a function of the Contractor. Refer to clause E03. Quality Assurance (QA) is a function of the Government. • USACE – Acronym for United States Army Corps of Engineers. • USCG - Acronym for United States Coast Guard.
Principal characteristics. The hull shall have the following principal dimensions: Length Overall Beam Overall Molded Depth (@ C.L.) Molded Depth (@ Side) 200’-0”56’-0”10’-6”10’-0” Light Ship Draft 6’-0” Max Draft 6’-6”
A. CONTRACT DOCUMENT
Principal characteristics. Composition of double-glazed units (symmetrical/asymmetrical) . . . . . . : Nominal thickness of the gap: . . . . . . . . . . . . . . . . . . . . . . : Method of assembly: . . . . . . . . . . . . . . . . . . . . . . . . . . . : Type of each glazing component as defined in annexes 5, 7, 9, 11 or 14 . : Documents attached: One form for the two panes of a symmetrical double-glazed unit in accordance with the annex under which the panes have been tested or approved. E/ECE/324 Rev.1/Add.42/Rev.1/Amend.1 Regulation No. 43 page 14 One form for each pane of an asymmetrical double-glazed unit in accordance with the annexes under which these panes have been tested or approved.