Regional Transmission Expansion Planning Protocol Sample Clauses

Regional Transmission Expansion Planning Protocol. The Members shall participate in regional transmission expansion planning in accordance with the Regional Transmission Expansion Planning Protocol set forth in Schedule 6 to this Agreement.
AutoNDA by SimpleDocs
Regional Transmission Expansion Planning Protocol. Regional Transmission Expansion Planning Protocol shall mean Schedule 6 of the Operating Agreement, or any successor thereto. Tariff.
Regional Transmission Expansion Planning Protocol. Regional Transmission Expansion Planning Protocol shall mean PJM Tariff, Schedule XXX, or any successor thereto. Required Transmission Enhancements shall have the meaning defined in the PJM Tariff. Regional Transmission Organization (RTO) shall mean an organization in effect during the term of this Agreement and approved by FERC as an RTO, as that term is defined in the applicable FERC regulations. Transmission Customer shall have the meaning defined in the PJM Tariff. Transmission Facilities shall mean those facilities that: (i) are within the PJM Region; (ii) meet the definition of transmission facilities pursuant to FERC’s Uniform System of Accounts or have been classified as transmission facilities in a ruling by FERC addressing such facilities; and (iii) have been demonstrated to the satisfaction of PJM to be integrated with the Transmission System of the PJM Region and integrated into the planning and operation of the PJM Region to serve the power and transmission customers within such region, regardless of whether the facilities are included in the transmission facilities list maintained by PJM. Transmission OwnerOwners A Transmission OwnerOwners shall mean any entitythose entities that ownsown or leaseslease (with rights equivalent to ownership) Transmission Facilities, provided that such entity has not transferred day-to-day management decisions of its Transmission Facilities or the authority to act for and on behalf of itself with respect to its Transmission Facilities to another entity that is not an Affiliate. . For purposes of this Agreement only, a Transmission Owner who is a generation and transmission cooperative (in addition to being the Transmission Owner for its own Transmission Facilities) shall also be the Transmission Owner for the Transmission Facilities of its cooperative members, with all rights and obligations specified under this agreement with regard to such Transmission Facilities, provided, however, that (a) it has been affirmatively granted in writing binding authority by such cooperative members to assume such rights and obligations, (b) that it affirmatively represents and warrants in writing to the other Parties and PJM that it has authority to act for and on behalf of such members, and (c) that any such cooperative member shall not be a Transmission Owner. Transmission Planned Outage shall mean any transmission outage scheduled in advance for a pre-determined duration and which meets the notification requirements for such...

Related to Regional Transmission Expansion Planning Protocol

  • Information Systems Acquisition Development and Maintenance a. Client Data – Client Data will only be used by State Street for the purposes specified in this Agreement.

  • Synchronization, Commissioning and Commercial Operation 4.1.1 The Power Producer shall give at least fifteen (15) days written notice to the SLDC / ALDC / DISCOM as the case may be, of the date on which it intends to synchronize the Power Project to the Grid System. 4.1.2 Subject to Article 4.1.1, the Power Project may be synchronized by the Power Producer to the Grid System when it meets all the connection conditions prescribed in the Grid Code and otherwise meets all other Indian legal requirements for synchronization to the Grid System. 4.1.3 The synchronization equipment and all necessary arrangements / equipment including Remote Terminal Unit (RTU) for scheduling of power generated from the Project and transmission of data to the concerned authority as per applicable regulation shall be installed by the Power Producer at its generation facility of the Power Project at its own cost. The Power Producer shall synchronize its system with the Grid System only after the approval of GETCO / SLDC / ALDC and GEDA. 4.1.4 The Power Producer shall immediately after each synchronization / tripping of generator, inform the sub-station of the Grid System to which the Power Project is electrically connected in accordance with applicable Grid Code. 4.1.5 The Power Producer shall commission the Project within SCOD. 4.1.6 The Power Producer shall be required to obtain Developer and/ or Transfer Permission, Key Plan drawing etc, if required, from GEDA. In cases of conversion of land from Agricultural to Non-Agriculture, the commissioning shall be taken up by GEDA only upon submission of N.A. permission by the Power Producer. 4.1.7 The Power Producer shall be required to follow the Forecasting and Scheduling procedures as per the Regulations issued by Hon’ble GERC from time to time. It is to clarify that in terms of GERC (Forecasting, Scheduling, Deviation Settlement and Related Matters of Solar and Wind Generation Sources) Regulations, 2019 the procedures for Forecasting, Scheduling & Deviation Settlment are applicable to all solar generators having combined installed capacity above 1 MW connected to the State Grid / Substation including those connected via pooling stations.

  • Commercial Operation Date Testing and Modifications Prior to the Commercial Operation Date, the Connecting Transmission Owner shall test the Connecting Transmission Owner’s Attachment Facilities and System Upgrade Facilities and System Deliverability Upgrades and Developer shall test the Large Generating Facility and the Developer Attachment Facilities to ensure their safe and reliable operation. Similar testing may be required after initial operation. Developer and Connecting Transmission Owner shall each make any modifications to its facilities that are found to be necessary as a result of such testing. Developer shall bear the cost of all such testing and modifications. Developer shall generate test energy at the Large Generating Facility only if it has arranged for the injection of such test energy in accordance with NYISO procedures.

  • Post-Commercial Operation Date Testing and Modifications Each Party shall at its own expense perform routine inspection and testing of its facilities and equipment in accordance with Good Utility Practice as may be necessary to ensure the continued interconnection of the Large Generating Facility with the Participating TO’s Transmission System in a safe and reliable manner. Each Party shall have the right, upon advance written notice, to require reasonable additional testing of the other Party’s facilities, at the requesting Party’s expense, as may be in accordance with Good Utility Practice.

  • Statewide HUB Program Statewide Procurement Division Note: In order for State agencies and institutions of higher education (universities) to be credited for utilizing this business as a HUB, they must award payment under the Certificate/VID Number identified above. Agencies, universities and prime contractors are encouraged to verify the company’s HUB certification prior to issuing a notice of award by accessing the Internet (xxxxx://xxxxx.xxx.xxxxx.xx.xx/tpasscmblsearch/index.jsp) or by contacting

  • Construction Phase Services 3.1.1 – Basic Construction Services

  • Development Phase contractual phase initiated with the approval of ANP for the Development Plan and which is extended during the Production Phase while investments in xxxxx, equipment, and facilities for the Production of Oil and Gas according to the Best Practices of the Oil Industry are required.

  • Network Interconnection Architecture Each Party will plan, design, construct and maintain the facilities within their respective systems as are necessary and proper for the provision of traffic covered by this Agreement. These facilities include but are not limited to, a sufficient number of trunks to the point of interconnection with the tandem company, and sufficient interoffice and interexchange facilities and trunks between its own central offices to adequately handle traffic between all central offices within the service areas at a P.01 grade of service or better. The provisioning and engineering of such services and facilities will comply with generally accepted industry methods and practices, and will observe the rules and regulations of the lawfully established tariffs applicable to the services provided.

  • Project Planning GOVERNMENTAL APPROVALS; ENVIRONMENTAL COMPLIANCE; PUBLIC INFORMATION 30 4.1 Planning and Engineering Activities 30 4.2 Site Conditions 30 4.3 Governmental Approvals 30 4.4 Environmental Compliance 34 4.5 Community Outreach and Public Information 35

Draft better contracts in just 5 minutes Get the weekly Law Insider newsletter packed with expert videos, webinars, ebooks, and more!