Supplemental Services For requests for supplemental services relating to Telecom Invoice Processing Services (TAPS) by Service Receiver not mentioned in this Schedule or not included within the costs documented in this agreement, Service Receiver will provide a discreet project request and submit such request to Service Provider using the formalized Change Request attached as Annex A for consideration by Service Provider. Where notice is required a number of business days prior to some required action by Service Provider, notice must be received by 12 noon Eastern Time to be counted as received during such business day. Service Provider shall, within a commercially reasonable period, provide a price quote to be commercially reasonable based on the current cost of the Services to Service Receiver taking into account, such items as the specific time the request was made, service delivery volumes, exit planning activities, and other activities Service Provider is currently engaged in at the time of the request, but not later than 30 days after the request was made. If Service Provider, in its sole discretion determines (i) such request would increase the ongoing operating costs for Service Provider (as a service recipient) or any other service receiver or (ii) that it is not capable of making such changes with its current staff during the time period requested without interrupting the Services provided to itself or any other service receiver. Service Provider need not provide a price quote or perform the services. Where a price quote is provided, Service Provider shall provide the service requested upon acceptance of the price.
Electrical Service Electrical service for new construction or a renovated existing building shall be 480/277-volt, 3-phase, 4-wire or approved equal. Service shall be sized for HVAC and other mechanical system(s) loads, lighting, general building services, and dedicated computer based office equipment loads. 5 xxxxx per square foot shall be provided for lighting and general service receptacles. Size of neutral conductor of 3- phase circuits shall be twice that of phase conductor to accommodate potential harmonic currents associated with computer system electronic power supplies and fluorescent lighting fixtures electronic ballasts. An adequately sized 3 phase “wye” wound step down transformer shall be provided to supply 208/120-volt, 3 phase power, for lighting, general service receptacles and dedicated computer based office equipment. Dedicated, isolated ground circuits shall be supplied from separate isolated ground power distribution panel(s). Lighting circuits shall be supplied from separate lighting panel(s). Panels shall have 20% spare capacity and be complete with 10% spare breakers of each size, but no less than 1 spare. No more than 4 duplex receptacles shall be connected to any single 20-amp dedicated isolated ground circuit or general service circuit.
Universal service 1. Each Party has the right to define the kind of universal service obligations it wishes to maintain.
Hospital Services The Hospital will: