Shipper Compression Sample Clauses

Shipper Compression. Collectively, any facilities installed by Shipper under Section 8.2.
AutoNDA by SimpleDocs
Shipper Compression. (a) Shipper shall have the right, at its own expense, to install compression facilities and plunger lifts upstream of the Receipt Points. Any such facilities installed by Shipper shall be installed, operated, and maintained in a manner that does not adversely affect (i) Gatherer’s dehydration, measurement, gathering or other facilities, (ii) the operation of the Gathering System, or (iii) any contractual obligations of Gatherer. (b) If, from time to time, Shipper desires to have lower pressures on all or any portion of a Sub-System, Gatherer and Shipper shall negotiate in good faith for Gatherer to install compression to lower pressures. If Gatherer and Shipper are unable to agree upon terms under which Gatherer would install such compression, then Gatherer shall allow Shipper to install, own and operate such compression facilities on the Gathering System as reasonably determined by Shipper. (c) Shipper shall provide the Field Fuel consumed in the operation of any Shipper Compression, unless Other Shippers also utilize Shipper Compression. (d) If Shipper installs Shipper Compression, Shipper shall indemnify, defend, and hold harmless the Gatherer Indemnified Parties from and against all Claims and Losses arising out of, or resulting from, the installation, operation, maintenance, or removal of such Shipper Compression, unless such claims were the result of negligence, gross negligence or willful misconduct of any of the Gatherer Indemnified Parties.

Related to Shipper Compression

  • Gas If Customer has selected a Gas Fixed Rate, Customer’s Price will be based on the Fixed Rate(s), plus the Administration Charge, set forth in the Application, which includes RITERATE ENERGY’s compressor fuel and transportation charges, administrative and transaction costs and the Gas Balancing Amount and any Regulatory Charges (defined below).

  • Pipelines Developer shall have no interest in the pipeline gathering system, which gathering system shall remain the sole property of Operator or its Affiliates and shall be maintained at their sole cost and expense.

  • Delivery Point The delivery point is the point of delivery of the Power Product to the CAISO Controlled Grid (the “Delivery Point”). Seller shall provide and convey to Buyer the Power Product from the Generating Facility at the Delivery Point. Title to and risk of loss related to the Power Product transfer from Seller to Buyer at the Delivery Point.

  • PRODUCER Subject to the terms of this Agreement, including Section 18.8, Producer shall release, indemnify, defend, and hold harmless Processor and its Affiliates, directors, officers, employees, agents, consultants, representatives, and invitees from and against all claims and losses arising out of or relating to (i) the operations of Producer and (ii) any breach of this agreement by Producer.

  • Interconnection Customer’s Interconnection Facilities The Interconnection Customer shall design, procure, construct, install, own and/or control the Interconnection Customer’s Interconnection Facilities described in Appendix A at its sole expense.

  • Interconnection Customer (1) Interconnection Customer shall construct and, unless otherwise indicated, shall own, the following Interconnection Facilities: None (2) In the event that, in accordance with the Interconnection Construction Service Agreement, Interconnection Customer has exercised the Option to Build, it is hereby permitted to build in accordance with and subject to the conditions and limitations set forth in that Section, the following portions of the Transmission Owner Interconnection Facilities which constitute or are part of the Customer Facility: None Ownership of the facilities built by Interconnection Customer pursuant to the Option to Build shall be as provided in the Interconnection Construction Service Agreement.

  • Interconnection Customer Provided Services The services provided by Interconnection Customer under this LGIA are set forth in Article 9.6 and Article 13.5. 1. Interconnection Customer shall be paid for such services in accordance with Article 11.6.

  • Delivery Points ‌ Project water made available to the Agency pursuant to Article 6 shall be delivered to the Agency by the State at the delivery structures established in accordance with Article 10.

  • Interconnection Customer Compensation If the CAISO requests or directs the Interconnection Customer to provide a service pursuant to Articles 9.6.3 (Payment for Reactive Power) or 13.5.1 of this LGIA, the CAISO shall compensate the Interconnection Customer in accordance with the CAISO Tariff.

  • Signaling Link Transport 9.2.1 Signaling Link Transport is a set of two or four dedicated 56 kbps transmission paths between Global Connection-designated Signaling Points of Interconnection that provide appropriate physical diversity.

Draft better contracts in just 5 minutes Get the weekly Law Insider newsletter packed with expert videos, webinars, ebooks, and more!