Technical Specifications for Voltage Controller Sample Clauses

Technical Specifications for Voltage Controller. Parameter Specifications / Details Broad Features Objective of voltage controller is to optimize the energy consumption of street lights by voltage control during off-peak hours Dimming level and dimming times (Off-peak hours) should be remotely settable. Dimming may be carried out either through voltage control or any other suitable mechanism subject to adherence to minimum lux levels and other requirements as specified in the SIOM Agreement. Irrespective of the mechanism, the dimming would need to be in steps (up to 10%, 20% & 30%). Bidders may however note that a mechanism resulting in non-glowing/switching off of LEDs / an array of LEDs in a fixture is not permitted for dimming purpose. Should be compatible with Harmonic filters installed in feeder panels. And should take in to account Conditions of Supply Code, 2004 issued by OERC. Other than basic switching components, no other moving parts should be there. Rating and Certification s The rating of Voltage controller should be at least 1.3 times the lighting load as estimated for new LED Fixtures during the initial studies prior to replacement. Voltage Rating: 150V to 260V. Set output voltage should be within +/- 5V during dimming. 240 V AC 50 Hz Single Phase Two Wire Or 415 V AC 50 Hz Three Phase Four Wire Input Supply with 3 Taps to Control output voltage. Intelligent dimming should be there; during off-peak hours. If input voltage itself is below 30% of rated voltage, further voltage reduction should not happen. Standard Output Voltage Taps In each Phase at 150/180/210 V AC @ 240 V AC to ensure maximum energy saving during off-peak hours During voltage tap changing, lights should not be momentarily disconnected which will lead to re- ignition of lights. It is mandatory for supplier to make gapless changeover arrangement when changing from by-pass mode to & from lower voltage energy saving mode and interchanging between the taps. This should be achieved by supplier by any specialized arrangements. The user is expected to produce the Performance assessment certificate for minimum continuous 100 such changeover operations without any lamps going off in any of the three phases at minimum and Maximum supply voltage conditions. This certificate should be received from reputed Laboratory organizations like CPRI, ETDC, ERTL, IDEMI, SAMEER etc. Voltage controller to be compatible with a microprocessor based Dual Channel Almanac Timer controller in feeder panel to facilitate used defined program for dimming ...
AutoNDA by SimpleDocs

Related to Technical Specifications for Voltage Controller

  • Technical Specifications The Technical Specifications furnished on the CD are intended to establish the standards for quality, performance and technical requirements for all labor, workmanship, material, methods and equipment necessary to complete the Work. When specifications and drawings are provided or referenced by the County, these are to be considered part of the Scope of Work, and to be specifically documented in the Detailed Scope of Work. For convenience, the County supplied specifications, if any, and the Technical Specifications furnished on the CD.

  • Technical Specification As enumerated in Special Conditions of Contract/Scope of Work/attached Drawing/ Details/Schedule of Rates.

  • DAF Specifications Developer shall submit initial specifications for the DAF, including System Protection Facilities, to Connecting Transmission Owner and NYISO at least one hundred eighty (180) Calendar Days prior to the Initial Synchronization Date; and final specifications for review and comment at least ninety (90) Calendar Days prior to the Initial Synchronization Date. Connecting Transmission Owner and NYISO shall review such specifications to ensure that the DAF are compatible with the technical specifications, operational control, and safety requirements of the Connecting Transmission Owner and NYISO and comment on such specifications within thirty (30) Calendar Days of Developer’s submission. All specifications provided hereunder shall be deemed to be Confidential Information.

  • General specifications 6.1.1. A vehicle and its electrical/electronic system(s) or ESA(s) shall be so designed, constructed and fitted as to enable the vehicle, in normal conditions of use, to comply with the requirements of this Regulation.

  • EODUF Packing Specifications 7.3.1 The data will be packed using ATIS EMI records. A pack will contain a minimum of one (1) message record or a maximum of ninety-nine thousand nine hundred and ninety-nine (99,999) message records plus a pack header record and a pack trailer record. One transmission can contain a maximum of ninety-nine (99) packs and a minimum of one (1) pack.

  • The Specifications The Specifications are that portion of the Contract Documents consisting of the written requirements for materials, equipment, systems, standards and workmanship for the Work, and performance of related services.

  • ODUF Packing Specifications 6.3.1 The data will be packed using ATIS EMI records. A pack will contain a minimum of one (1) message record or a maximum of ninety-nine thousand nine hundred and ninety-nine (99,999) message records plus a pack header record and a pack trailer record. One transmission can contain a maximum of ninety-nine (99) packs and a minimum of one (1) pack.

  • Service Specification The Parties have agreed upon the scope and specification of the Services provided under this Service Agreement in the Service Specification.

  • Billing Specifications 55.6.1 The Parties agree that billing requirements and outputs will be consistent with the Ordering & Billing Form (OBF) and also with Telcordia Technologies Billing Output Specifications (BOS).

  • Technical Specifications and Drawings a) The Goods and Related Services supplied under this Contract shall conform to the technical specifications and standards mentioned in Section VI, Schedule of Requirements and, when no applicable standard is mentioned, the standard shall be equivalent or superior to the official standards whose application is appropriate to the Goods' country of origin.

Time is Money Join Law Insider Premium to draft better contracts faster.