Uncovering and Correction of Work 12.1 The Contractor shall promptly correct Work rejected by the Owner or failing to conform to the requirements of the Contract Documents, whether observed before or after Substantial Completion and whether or not fabricated, installed or completed, and shall correct any Work found to be not in accordance with the requirements of the Contract Documents within a period of two years from the date of Substantial Completion, or by terms of an applicable special warranty required by the Contract Documents. The provisions of this Article apply to work done by Subcontractors as well as to Work done by direct employees of the Contractor. 12.2 At any time during the progress of the work, or in any case where the nature of the defects shall be such that it is not expedient to have them corrected, the Owner, at their option, shall have the right to deduct such sum, or sums, of money from the amount of the contract as they consider justified to adjust the difference in value between the defective work and that required under contract including any damage to the structure.
UNCOVERING OF WORK 13.1.1 If any portion of the Work should be covered contrary to the request of the Architect or to requirements specifically expressed in the Contract Documents, it must, if required in writing by the Architect, be uncovered for his or her observation and shall be replaced at the Contractor's expense. 13.1.2 If any other portion of the Work has been covered which the Architect has not specifically requested to observe prior to being covered, the Architect may request to see such Work and it shall be uncovered by the Contractor. If such Work is found in accordance with the Contract Documents, the cost of uncovering and replacement shall, by appropriate Change Order, be charged to the State. If such Work is found not to be in accordance with the Contract Documents, the Contractor shall pay such costs unless it is found that this condition was caused by the State or a separate contractor as provided in Article 6 of these General Conditions, in which event the State shall be responsible for the payment of such costs.
Undercharging (a) If we have undercharged you, we may recover the undercharged amount from you. If we recover an undercharged amount from you: (i) we will not charge interest on the undercharged amount; and (ii) we will offer you time to pay the undercharged amount in instalments over the same period of time during which you were undercharged (if less than 12 months), or otherwise over 12 months. (b) The maximum amount we can recover from you is limited to the amount that has been undercharged in the 9 months immediately before we notify you, unless the undercharge is your fault, or results from your unlawful act or omission.
Classrooms The Board shall be responsible for maintaining a standard of cleanliness in each teacher’s classroom.
Overcharging (a) Where you have been overcharged by less than $50, and you have already paid the overcharged amount, we must credit that amount to your next bill. (b) Where you have been overcharged by $50 or more, we must inform you within 10 business days of our becoming aware of the overcharge and, if you have already paid that amount, we must credit that amount to your next bill. However, if you request otherwise, we will comply with that request. (c) If you have stopped buying energy from us, we will use our best endeavours to pay the overcharged amount to you within 10 business days. (d) If you have been overcharged as a result of your own fault or unlawful act or omission, we may limit the amount we credit or pay you to the amount you were overcharged in the last 12 months.
Estimating Marketing and sales:
Technical Training The CAISO and the Participating TOs shall respond to reasonable requests for support and provide relevant technical training to each other’s employees to support the safe, reliable, and efficient operation of the CAISO Controlled Grid and to comply with any NERC or WECC operator certification or training requirements. Examples of such technical training include, but are not limited to: (1) the theory or operation of new or modified equipment (e.g., control systems, Remedial Action Schemes, protective relays); (2) computer and applicator programs; and (3) CAISO (or Participating TO) requirements. The Parties shall enter into agreements regarding the timing, term, locations, and cost allocation for the training.
Configuration The configuration for the Purchase Right Aircraft will be the Detail Specification for Model 767-3S2F aircraft at the revision level in effect at the time of the Supplemental Agreement. Such Detail Specification will be revised to include (i) changes required to obtain required regulatory certificates and (ii) other changes as mutually agreed upon by Boeing and Customer.
Underutilization Underutilization of Interconnection Trunks and facilities exists when provisioned capacity of trunks in service for more than six (6) months is greater than the current need. This over-provisioning is an inefficient deployment and use of network resources and results in unnecessary costs. Those situations where more capacity exists than actual usage will be handled in the following manner: a. If a final trunk group is under seventy-five percent (75%) of CCS capacity or a high usage trunk group is under 90% of CCS capacity on a monthly average basis, for each month of any three (3) consecutive months period, either Party may request the issuance of an order to resize the trunk group, which shall be left with not less than twenty-five percent (25%) excess capacity. In all cases POI requirements and grade of service objectives shall be maintained. b. CLEC will send an ASR to CenturyLink to trigger changes to the Local Interconnection Trunk Groups based on capacity assessment.
Downtime There may be downtime during the Migration. The duration of the downtime will depend on the amount of data that Agency is migrating. Axon will work with Agency to minimize any downtime. Any VIEVU mobile application will need to be disabled upon Migration.