Verification of Primary Metering Equipment Sample Clauses

Verification of Primary Metering Equipment. (a) The Operator: (i) must, at least once each month (or other period agreed between the parties) during the duration of this Contract; and (ii) may, at such greater frequency or on any occasion that either Party may request, verify the accuracy of any Primary Metering Equipment in accordance with a procedure described in clause 15.11(b). (b) The Verification procedure consists of: (i) a comparison between simultaneous independent measurements of Gas flows; (ii) the physical substitution of the Primary Metering Equipment to be Verified with similar Metering Equipment having a demonstrated accuracy within the Prescribed Limits of Uncertainty; or (iii) any Metering Equipment testing procedure complying with applicable Australian or International standards that the Parties agree in writing to use. (c) Each Party may have representatives present at the time of any Verification of the Accuracy of any Primary Metering Equipment (unless the number of persons present must be restricted for safety or logistical reasons, in which case the Parties are to agree on which representatives must be present), and the Operator must give the Shipper sufficient notice of an intended Verification to enable the Shipper's representative to be present. (d) The results of any Verification are binding on both Parties unless within 7 Working Days after a Verification either Party gives notice to the other Party that it disputes the conduct of the Verification, in which case: (i) the provisions of clause 24 apply; and (ii) any reference in this clause 15.11 to accuracy figures produced by a Verification means the accuracy figures finally determined for that Verification under a dispute resolution process adopted in accordance with clause 24. (e) Subject to clause 15.11(f), the Shipper must bear the expense of any Verification under clause 15.11(a), provided that the Operator must bear the cost of attendance of the Operator's representatives. (f) If a Verification requested by the Operator under clause 15.11(a)(ii) reveals that the accuracy of the Primary Metering Equipment is within the Prescribed Limits of Uncertainty, the Operator must bear the expense of the Verification and must also pay to the Shipper the Shipper's reasonable expenses of that Verification, in accordance with clause 20.
AutoNDA by SimpleDocs

Related to Verification of Primary Metering Equipment

  • Metering Equipment 13.01. Utility will furnish, install, own and maintain metering equipment capable of measuring the flow of kilowatt-hours (kWh) of energy. The Customer's service associated with the CRG will be metered at a single metering point. The metering equipment will measure energy delivered by Utility to Customer and also measure energy delivered by Customer to Utility. Customer agrees to provide safe and reasonable access to the premises for installation of this equipment and its future maintenance or removal.

  • Testing of Metering Equipment Connecting Transmission Owner shall inspect and test all of its Metering Equipment upon installation and at least once every two (2) years thereafter. If requested to do so by NYISO or Developer, Connecting Transmission Owner shall, at Developer’s expense, inspect or test Metering Equipment more frequently than every two (2) years. Connecting Transmission Owner shall give reasonable notice of the time when any inspection or test shall take place, and Developer and NYISO may have representatives present at the test or inspection. If at any time Metering Equipment is found to be inaccurate or defective, it shall be adjusted, repaired or replaced at Developer’s expense, in order to provide accurate metering, unless the inaccuracy or defect is due to Connecting Transmission Owner’s failure to maintain, then Connecting Transmission Owner shall pay. If Metering Equipment fails to register, or if the measurement made by Metering Equipment during a test varies by more than two percent from the measurement made by the standard meter used in the test, Connecting Transmission Owner shall adjust the measurements by correcting all measurements for the period during which Metering Equipment was in error by using Developer’s check meters, if installed. If no such check meters are installed or if the period cannot be reasonably ascertained, the adjustment shall be for the period immediately preceding the test of the Metering Equipment equal to one-half the time from the date of the last previous test of the Metering Equipment. The NYISO shall reserve the right to review all associated metering equipment installation on the Developer’s or Connecting Transmission Owner’s property at any time.

  • Metering The Interconnection Customer shall be responsible for the Connecting Transmission Owner’s reasonable and necessary cost for the purchase, installation, operation, maintenance, testing, repair, and replacement of metering and data acquisition equipment specified in Attachments 2 and 3 of this Agreement. The Interconnection Customer’s metering (and data acquisition, as required) equipment shall conform to applicable industry rules and Operating Requirements.

  • Electrical Equipment Residents must use only CSA, UL-approved or Canadian-certified electrical equipment; the rated wattage of light fixtures must never be exceeded; and only replacement bulbs supplied by Waterloo maintenance staff may be used. Do not leave any unattended electrical equipment turned on (i.e. hair straighteners, lights etc.)

  • Equipment Specifications All equipment must meet the contract specifications and all federal and State safety codes and regulations in effect at the date of manufacture. All equipment must be Original Equipment Manufacturer (OEM) equipment unless otherwise stated in the contract. All products, materials, supplies, replacement parts, and equipment offered and furnished must be new, of current manufacturer production, and must have been formally announced by the manufacturer as being commercially available, unless otherwise stated in this Contract.

  • Ownership and Location of Metering Equipment The Metering Equipment to be constructed, the capability of the Metering Equipment to be constructed, and the ownership thereof, are identified on the attached Schedule C to this ISA.

  • Accessories, Spare Parts and Tools Accessories, spare parts and tools dispatched with a piece of equipment, machine, apparatus or vehicle, which are part of the normal equipment and included in the price thereof or which are not separately invoiced, shall be regarded as one with the piece of equipment, machine, apparatus or vehicle in question.

  • Additional Equipment Additional Equipment may from time to time be added as the subject matter of this Agreement as agreed on by the parties. Any additional property will be added in an amendment describing the property, the monthly rental, security deposit, and stipulated loss value of the additional Equipment. All amendments must be in writing and signed by both parties. Other than by this amendment procedure, this Agreement may not be amended, modified, or altered in any manner except in writing signed by both parties.

  • MEASURING EQUIPMENT 1. Seller will maintain and operate, atlts own, expense and atthe point of delivery of gas hereunder, a meter or meters and othernecessary equipment by which the volume of gas delivered hereunder shall be measured. Such meters and equipment shall remain the property of the Seller. 2. Buyer agrees lo furnish to Seller electricity for operating Seller's meters, at not cost to Seller. 3. Buyer hereby grants to Seller suitable rlghts-0f-way and easements necessary or Incidental for the installatioo, maintenance, operation and removal of pipeline and other facilities together with rights ofingress thereto and egress there from at all times and hereby agrees to deliver to Seller, for the sum of one dollar ($1.00), an appropriate instrument or grant defining such rights and easements located on Buyer's planlslte. 4. Buyer may install, maintain and operate such check measuring equipment, Including arecording gravltometer and calorimeter as it shall desire, provided that such equipment shall be so installed so as not to Interfere with the operation of Seller's measuring equipment at or near the point of deliver. However, all xxxxxxxx to the Buyer shall be based on the metering of the Seller, subject only to the provisions of Paragraph 8 of this Article. 5. Each party shall have the right to be present at the time of any installing, reading, cleaning, changing, repairing, Inspecting, testing, calibrating, or adjusting done In connection with the other's measuring equlpme!lt used in measuring deliveries hereunder and each party shall advise the other of any Intended major maintenance operation sufficiently in advance in order that the other party may conveniently have its representative present. 6. All installatioo of measuring equipmenL applying to or effecting deliveries hereunder, shall be rnade in such manner as to perrnit an accurate detenninalion of the quantity of gas delivered and ready verification of the accuracy of measurement Orifice meter Installations, If used, shall oonforrn lo the recommendation for design and lnstallatioo contained in the Gas Measurement Commiltee Report No. 3 to the American Gas Association published April, 1955, and any modificatioos and amendments thereof and shall include the use of flange connections. 7. Measurement on Seller's meter or meters shall be conclusive of both parties except where the meter Is defective or fails to register, or if found in E)rror, in either of which case Seller shall repair or replace the meter and the quantity of gas delivered while the meter was out of order or failed to register shall be estimated: (a) By using the registration of any check meter If installed and accurately registering, or, In the absence of (a): (b) By correcting the error If the percentage of error by calibration, test or mathematical calculation, or, in the absence of both (a) and (b) then: (c) By estimating the quantity of delivery from deliveries during periods under similar oonditions when the meter was registering actUrately; and an appropriate billing adjusbnentshall be made In accordance with the current Rules and Regulations governing gas systems issued by the Commission. 8. Seller will maintain its meters in .good order and to this end Wiii make periodic tests of its meters pursuant to the current Rules and Regulations governing gas systems issued by the Commission, or at such shorter intervals as seem to Seller desirable. lfBuyer Is dissatisfied with the accuracy at eny time, it may call upon Seller to have Iha meter tested in accordance with all regulatioos relating to such tests and results of such tesls as found in the current Rules and Regulations governing gas systems issued by the Commission. 9. Each party shall preserve all records for aperiod of at least two (2) years.

  • Equipment Cleaning (a) Areas, known by Forest Service prior to timber sale advertisement, that are infested with invasive species of concern are shown on Sale Area Map. A current list of invasive species of concern and a map showing the extent of known infestations is available at the Forest Supervisor’s Office. For purposes of this provision, “Off-Road Equipment” includes all logging and construction machinery, except for log trucks, chip vans, service vehicles, water trucks, pickup trucks, cars, and similar vehicles.

Draft better contracts in just 5 minutes Get the weekly Law Insider newsletter packed with expert videos, webinars, ebooks, and more!