Electrostatic spray means a method of applying a spray coating in which opposite electric charges are applied to the substrate and the coating. The coating is attracted to the substrate by the electrostatic potential between them.
High global warming potential hydrofluorocarbons means any hydrofluorocarbons in a particular end use for which EPA’s Significant New Alternatives Policy (SNAP) program has identified other acceptable alternatives that have lower global warming potential. The SNAP list of alternatives is found at 40 CFR Part 82 subpart G with supplemental tables of alternatives available at (http://www.epa.gov/snap/).
high voltage means the classification of an electric component or circuit, if its working voltage is > 60 V and ≤ 1500 V DC or > 30 V and ≤ 1000 V AC root mean square (rms).
Industrial radiography means an examination of the structure of materials by the nondestructive method of utilizing ionizing radiation to make radiographic images.
Polystyrene foam adhesive means an aerosol adhesive designed to bond polystyrene foam to substrates.
Instantaneous flow measurement means the flow measured during the minimum time required for the flow-measuring device or method to produce a result in that instance. To the extent practical, instantaneous flow measurements coincide with the collection of any grab samples required for the same sampling period so that together the samples and flow are representative of the discharge during that sampling period.
Biologically-based mental illness means schizophrenia, schizoaffective disorder, major depressive disorder, bipolar disorder, paranoia and other psychotic disorders, obsessive-compulsive disorder, and panic disorder, as these terms are defined in the most recent edition of the diagnostic and statistical manual of mental disorders published by the American Psychiatric Association.
Membrane filtration means a pressure or vacuum driven separation process in which particulate matter larger than one micrometer is rejected by an engineered barrier, primarily through a size exclusion mechanism, and which has a measurable removal efficiency of a target organism that can be verified through the application of a direct integrity test. This definition includes the common membrane technologies of microfiltration, ultrafiltration, nanofiltration, and reverse osmosis.
Disinfection means a process which inactivates pathogenic organisms in water by chemical oxidants or equivalent agents.
Disinfection profile means a summary of daily Giardia lamblia inactivation through the treatment plant. The procedure for developing a disinfection profile is contained in s. NR 810.32.
Biological agent shall mean any pathogenic (disease producing) micro-organism(s) and/or biologically produced toxin(s) (including genetically modified organisms and chemically synthesized toxins) which cause illness and/or death in humans, animals or plants.
polygamous marriage means any marriage to which paragraph 5 applies;
Acute toxicity means concurrent and delayed adverse effects that result from an acute exposure and occur within any short observation period, which begins when the exposure begins, may extend beyond the exposure period, and usually does not constitute a substantial portion of the life span of the organism.
Diatomaceous earth filtration means a process resulting in substantial particulate removal in which (1) a precoat cake of diatomaceous earth filter media is deposited on a support membrane (septum), and (2) while the water is filtered by passing through the cake on the septum, additional filter media known as body feed is continuously added to the feed water to maintain the permeability of the filter cake.
Web spray adhesive means any aerosol adhesive that is not a mist spray or special purpose spray adhesive.
Tomographic plane means that geometric plane which is identified as corresponding to the output tomogram.
Cabinet radiography means industrial radiography conducted in an enclosure or cabinet shielded so that radiation levels at every location on the exterior meet the limitations specified in 641—40.26(136C).
Cabinet x-ray system means an x-ray system with the x-ray tube installed in an enclosure independent of existing architectural structures except the floor on which it may be placed. The cabinet x-ray system is intended to contain at least that portion of a material being irradiated, provide radiation attenuation, and exclude personnel from its interior during generation of radiation. Included are all x-ray systems designed primarily for the inspection of carry-on baggage at airline, railroad, and bus terminals, and in similar facilities. An x-ray tube used within a shielded part of a building, or x-ray equipment that may temporarily or occasionally incorporate portable shielding, is not considered a cabinet x-ray system.
General purpose radiographic x-ray system means any radiographic x-ray system which, by design, is not limited to radiographic examination of specific anatomical regions.
Cyanoacrylate adhesive means any adhesive with a cyanoacrylate content of at least 95% by weight.
Fluoroscopic imaging assembly means a subsystem in which X-ray photons produce a visual image. It includes the image receptor(s) such as the image intensifier and spot-film device, electrical interlocks, if any, and structural material providing linkage between the image receptor and diagnostic source assembly.
Chronic toxicity means concurrent and delayed adverse effects that occur only as a result of a chronic exposure.
Leak of UPSI means communication of information which is/deemed to be UPSI by any person, who is in possession of UPSI, to any other person, directly or indirectly, overtly or covertly or in any manner whatsoever, except for legitimate purposes, performance of duties or discharge of legal obligations.