- C and M Employees shall be designated under the following bargaining unit department. - Custodial and Maintenance
Reporting and Monitoring Please provide a brief description of the mechanisms proposed for this project for reporting to the UNDP and partners, including a reporting schedule.
Start-Up and Synchronization Consistent with the mutually acceptable procedures of the Developer and Connecting Transmission Owner, the Developer is responsible for the proper synchronization of the Large Generating Facility to the New York State Transmission System in accordance with NYISO and Connecting Transmission Owner procedures and requirements.
Manufacturing and Marketing Rights The Company has not granted rights to manufacture, produce, assemble, license, market, or sell its products to any other person and is not bound by any agreement that affects the Company's exclusive right to develop, manufacture, assemble, distribute, market, or sell its products.
Promotion and Marketing For the purpose of promotion and marketing, the Borrower hereby authorizes and consents to the reproduction, disclosure and use by the Lenders and the Agent of its name, identifying logo and the Facilities. The Borrower acknowledges and agrees that the Lenders shall be entitled to determine, in their sole discretion, whether to use such information; that no compensation will be payable by the Lenders or the Agent in connection therewith; and that the Lenders and the Agent shall have no liability whatsoever to it or any of its employees, officers, directors, affiliates or shareholders in obtaining and using such information as contemplated herein.
Advertising and Marketing Except in so far as herein expressly provided, the Service Provider shall not make or issue any formal or informal announcement (with the exception of Stock Exchange announcements), advertisement or statement to the media in connection with this Agreement or otherwise disclose the existence of this Agreement or the subject matter thereof to any other person without the prior written consent of SARS.
Access to NID 2.7.3.1 NewPhone may access the customer’s premises wiring by any of the following means and NewPhone shall not disturb the existing form of electrical protection and shall maintain the physical integrity of the NID: 2.7.3.1.1 BellSouth shall allow NewPhone to connect its Loops directly to BellSouth’s multi-line residential NID enclosures that have additional space and are not used by BellSouth or any other telecommunications carriers to provide service to the premises; 2.7.3.1.2 Where an adequate length of the customer’s premises wiring is present and environmental conditions permit, either Party may remove the customer premises wiring from the other Party’s NID and connect such wiring to that Party’s own NID; 2.7.3.1.3 Either Party may enter the subscriber access chamber or dual chamber NID enclosures for the purpose of extending a cross-connect or spliced jumper wire from the customer premises wiring through a suitable “punch-out” hole of such NID enclosures; or 2.7.3.1.4 NewPhone may request BellSouth to make other rearrangements to the customer premises wiring terminations or terminal enclosure on a time and materials cost basis. 2.7.3.2 In no case shall either Party remove or disconnect the other Party’s loop facilities from either Party’s NIDs, enclosures, or protectors unless the applicable Commission has expressly permitted the same and the disconnecting Party provides prior notice to the other Party. In such cases, it shall be the responsibility of the Party disconnecting loop facilities to leave undisturbed the existing form of electrical protection and to maintain the physical integrity of the NID. It will be NewPhone’s responsibility to ensure there is no safety hazard, and NewPhone will hold BellSouth harmless for any liability associated with the removal of the BellSouth Loop from the BellSouth NID. Furthermore, it shall be the responsibility of the disconnecting Party, once the other Party’s loop has been disconnected from the NID, to reconnect the disconnected loop to a nationally recognized testing laboratory listed station protector, which has been grounded as per Article 800 of the National Electrical Code. If no spare station protector exists in the NID, the disconnected loop must be appropriately cleared, capped and stored. 2.7.3.3 NewPhone shall not remove or disconnect ground wires from BellSouth’s NIDs, enclosures, or protectors. 2.7.3.4 NewPhone shall not remove or disconnect NID modules, protectors, or terminals from BellSouth’s NID enclosures. 2.7.3.5 Due to the wide variety of NID enclosures and outside plant environments, BellSouth will work with NewPhone to develop specific procedures to establish the most effective means of implementing this section if the procedures set forth herein do not apply to the NID in question.
EVALUATION AND MONITORING The ORGANIZATION agrees to maintain books, records and other documents and evidence, and to use accounting procedures and practices that sufficiently and properly support the complete performance of and the full compliance with this Agreement. The ORGANIZATION will retain these supporting books, records, documents and other materials for at least three (3) calendar years following the year in which the Agreement expires. The COUNTY and/or the State Auditor and any of their representatives shall have full and complete access to these books, records and other documents and evidence retained by the ORGANIZATION respecting all matters covered in and under this Agreement, and shall have the right to examine such during normal business hours as often as the COUNTY and/or the State Auditor may deem necessary. Such representatives shall be permitted to audit, examine and make excerpts or transcripts from such records, and to make audits of all contracts, invoices, materials, and records of matters covered by this Agreement. These access and examination rights shall last for three calendar years following the year in which the Agreement expires. The COUNTY intends without guarantee for its agents to use reasonable security procedures and protections to assure that related records and documents provided by the ORGANIZATION are not erroneously disclosed to third parties. The COUNTY will, however, disclose or make this material available to those authorized by/in the above paragraph or permitted under the provisions of Chapter 42.56 RCW without notice to the ORGANIZATION. The ORGANIZATION shall cooperate with and freely participate in any other monitoring or evaluation activities pertinent to this Agreement that the COUNTY finds needing to be conducted.
Access to Services Subject to and in accordance with the terms of this Agreement, including any Schedules, Company grants You a non-exclusive, non-sublicensable, nontransferable, non-assignable, revocable license for the term of this Agreement to access and use the Services. Services may only be used by Your Users for internal business purposes only. You agree to comply with the terms and conditions of this Agreement, including any Schedules, and with all applicable Company procedures and policies that further define use of the Services. You acknowledge and agree that the actions of any of Your Users with respect to the Services will be deemed to be actions by You and that any breach by any of Your Users of the terms of this Agreement, including any Schedule, will be deemed to be a breach by You.
Synchronization The Licensor hereby grants limited synchronization rights for One (1) music video streamed online (Youtube, Vimeo, etc..) for up to 500,000 non-monetized video streams on all total sites. A separate synchronisation license will need to be purchased for distribution of video to Television, Film or Video game.