Access to NID 2.7.3.1 NewPhone may access the customer’s premises wiring by any of the following means and NewPhone shall not disturb the existing form of electrical protection and shall maintain the physical integrity of the NID: 2.7.3.1.1 BellSouth shall allow NewPhone to connect its Loops directly to BellSouth’s multi-line residential NID enclosures that have additional space and are not used by BellSouth or any other telecommunications carriers to provide service to the premises; 2.7.3.1.2 Where an adequate length of the customer’s premises wiring is present and environmental conditions permit, either Party may remove the customer premises wiring from the other Party’s NID and connect such wiring to that Party’s own NID; 2.7.3.1.3 Either Party may enter the subscriber access chamber or dual chamber NID enclosures for the purpose of extending a cross-connect or spliced jumper wire from the customer premises wiring through a suitable “punch-out” hole of such NID enclosures; or 2.7.3.1.4 NewPhone may request BellSouth to make other rearrangements to the customer premises wiring terminations or terminal enclosure on a time and materials cost basis. 2.7.3.2 In no case shall either Party remove or disconnect the other Party’s loop facilities from either Party’s NIDs, enclosures, or protectors unless the applicable Commission has expressly permitted the same and the disconnecting Party provides prior notice to the other Party. In such cases, it shall be the responsibility of the Party disconnecting loop facilities to leave undisturbed the existing form of electrical protection and to maintain the physical integrity of the NID. It will be NewPhone’s responsibility to ensure there is no safety hazard, and NewPhone will hold BellSouth harmless for any liability associated with the removal of the BellSouth Loop from the BellSouth NID. Furthermore, it shall be the responsibility of the disconnecting Party, once the other Party’s loop has been disconnected from the NID, to reconnect the disconnected loop to a nationally recognized testing laboratory listed station protector, which has been grounded as per Article 800 of the National Electrical Code. If no spare station protector exists in the NID, the disconnected loop must be appropriately cleared, capped and stored. 2.7.3.3 NewPhone shall not remove or disconnect ground wires from BellSouth’s NIDs, enclosures, or protectors. 2.7.3.4 NewPhone shall not remove or disconnect NID modules, protectors, or terminals from BellSouth’s NID enclosures. 2.7.3.5 Due to the wide variety of NID enclosures and outside plant environments, BellSouth will work with NewPhone to develop specific procedures to establish the most effective means of implementing this section if the procedures set forth herein do not apply to the NID in question.
Access to Site 3.05.1 Contractor may enter and leave the premises at all reasonable times without charge. Contractor and its employees may use the common areas and roadways of the premises where it is to perform the services together with all facilities, equipment, improvements, and services provided in connection with the premises for common use. This excludes parking for Contractor’s personnel. Contractor shall repair any damage caused by it or its employees as a result of its use of the common areas.
General Conditions Applicable to Option to Build If the Interconnection Customer assumes responsibility for the design, procurement and construction of the Participating TO's Interconnection Facilities and Stand Alone Network Upgrades, (1) the Interconnection Customer shall engineer, procure equipment, and construct the Participating TO's Interconnection Facilities and Stand Alone Network Upgrades (or portions thereof) using Good Utility Practice and using standards and specifications provided in advance by the Participating TO; (2) The Interconnection Customer’s engineering, procurement and construction of the Participating TO's Interconnection Facilities and Stand Alone Network Upgrades shall comply with all requirements of law to which the Participating TO would be subject in the engineering, procurement or construction of the Participating TO's Interconnection Facilities and Stand Alone Network Upgrades; (3) the Participating TO shall review, and the Interconnection Customer shall obtain the Participating TO’s approval of, the engineering design, equipment acceptance tests, and the construction of the Participating TO's Interconnection Facilities and Stand Alone Network Upgrades, which approval shall not be unreasonably withheld, and the CAISO may, at its option, review the engineering design, equipment acceptance tests, and the construction of the Participating TO's Interconnection Facilities and Stand Alone Network Upgrades; (4) prior to commencement of construction, the Interconnection Customer shall provide to the Participating TO, with a copy to the CAISO for informational purposes, a schedule for construction of the Participating TO's Interconnection Facilities and Stand Alone Network Upgrades, and shall promptly respond to requests for information from the Participating TO; (5) at any time during construction, the Participating TO shall have the right to gain unrestricted access to the Participating TO's Interconnection Facilities and Stand Alone Network Upgrades and to conduct inspections of the same; (6) at any time during construction, should any phase of the engineering, equipment procurement, or construction of the Participating TO's Interconnection Facilities and Stand Alone Network Upgrades not meet the standards and specifications provided by the Participating TO, the Interconnection Customer shall be obligated to remedy deficiencies in that portion of the Participating TO's Interconnection Facilities and Stand Alone Network Upgrades; (7) the Interconnection Customer shall indemnify the CAISO and Participating TO for claims arising from the Interconnection Customer's construction of the Participating TO's Interconnection Facilities and Stand Alone Network Upgrades under the terms and procedures applicable to Article 18.1
RELEASE OF GENERAL INFORMATION TO THE PUBLIC AND MEDIA NASA or Partner may, consistent with Federal law and this Agreement, release general information regarding its own participation in this Agreement as desired. Pursuant to Section 841(d) of the NASA Transition Authorization Act of 2017, Public Law 115-10 (the "NTAA"), NASA is obligated to publicly disclose copies of all agreements conducted pursuant to NASA's 51 U.S.C. §20113(e) authority in a searchable format on the NASA website within 60 days after the agreement is signed by the Parties. The Parties acknowledge that a copy of this Agreement will be disclosed, without redactions, in accordance with the NTAA.
Access to Information Systems Access, if any, to DXC’s Information Systems is granted solely to perform the Services under this Order, and is limited to those specific DXC Information Systems, time periods and personnel as are separately agreed to by DXC and Supplier from time to time. DXC may require Supplier’s employees, subcontractors or agents to sign individual agreements prior to access to DXC’s Information Systems. Use of DXC Information Systems during other time periods or by individuals not authorized by DXC is expressly prohibited. Access is subject to DXC business control and information protection policies, standards and guidelines as may be modified from time to time. Use of any other DXC Information Systems is expressly prohibited. This prohibition applies even when an DXC Information System that Supplier is authorized to access, serves as a gateway to other Information Systems outside Supplier’s scope of authorization. Supplier agrees to access Information Systems only from specific locations approved for access by DXC. For access outside of DXC premises, DXC will designate the specific network connections to be used to access Information Systems.
Data Return and Destruction of Data (a) Protecting PII from unauthorized access and disclosure is of the utmost importance to the EA, and Contractor agrees that it is prohibited from retaining PII or continued access to PII or any copy, summary or extract of PII, on any storage medium (including, without limitation, in secure data centers and/or cloud-based facilities) whatsoever beyond the period of providing Services to the EA, unless such retention is either expressly authorized for a prescribed period by the Service Agreement or other written agreement between the Parties, or expressly requested by the EA for purposes of facilitating the transfer of PII to the EA or expressly required by law. As applicable, upon expiration or termination of the Service Agreement, Contractor shall transfer PII, in a format agreed to by the Parties to the EA. (b) If applicable, once the transfer of PII has been accomplished in accordance with the EA’s written election to do so, Contractor agrees to return or destroy all PII when the purpose that necessitated its receipt by Contractor has been completed. Thereafter, with regard to all PII (including without limitation, all hard copies, archived copies, electronic versions, electronic imaging of hard copies) as well as any and all PII maintained on behalf of Contractor in a secure data center and/or cloud-based facilities that remain in the possession of Contractor or its Subcontractors, Contractor shall ensure that PII is securely deleted and/or destroyed in a manner that does not allow it to be retrieved or retrievable, read or reconstructed. Hard copy media must be shredded or destroyed such that PII cannot be read or otherwise reconstructed, and electronic media must be cleared, purged, or destroyed such that the PII cannot be retrieved. Only the destruction of paper PII, and not redaction, will satisfy the requirements for data destruction. Redaction is specifically excluded as a means of data destruction. (c) Contractor shall provide the EA with a written certification of the secure deletion and/or destruction of PII held by the Contractor or Subcontractors. (d) To the extent that Contractor and/or its subcontractors continue to be in possession of any de-identified data (i.e., data that has had all direct and indirect identifiers removed), they agree not to attempt to re-identify de-identified data and not to transfer de-identified data to any party.
Access to Services Subject to and in accordance with the terms of this Agreement, including any Schedules, Company grants You a non-exclusive, non-sublicensable, nontransferable, non-assignable, revocable license for the term of this Agreement to access and use the Services. Services may only be used by Your Users for internal business purposes only. You agree to comply with the terms and conditions of this Agreement, including any Schedules, and with all applicable Company procedures and policies that further define use of the Services. You acknowledge and agree that the actions of any of Your Users with respect to the Services will be deemed to be actions by You and that any breach by any of Your Users of the terms of this Agreement, including any Schedule, will be deemed to be a breach by You.
RECEIPT AND PUBLICATION OF NOTICES 10.1 Immediately after it receives a demand or notice from any Noteholder in accordance with the Conditions, the Agent shall forward a copy to the Issuer. 10.2 On behalf of and at the request and expense of the Issuer, the Agent shall cause to be published all notices required to be given by the Issuer to the Noteholders in accordance with the Conditions.
ACCESS TO SECURITY LOGS AND REPORTS Upon request, the Contractor shall provide access to security logs and reports to the State or Authorized User in a format as specified in the Authorized User Agreement.
Use of Interconnection Facilities by Third Parties 6551 Error! Hyperlink reference not valid.9.9.1 Purpose of Interconnection Facilities. 6551