Bonding and Outer-insulation System Sample Clauses

Bonding and Outer-insulation System. No material, other than those detailed in this section shall be included in the coil without the written permission of the Contracting Authority or its authorised representative. All materials must be suitable for use in a high radiation environment. The resin bonding system shall comprise a radiation-resistant epoxy resin with an anhydride curing agent, with optional inclusion of an accelerator. The choice of the resin Bidder, the resin type and the curing agent are left to the Bidder. However, this choice is part of the offer and must be indicated within the offer, with corresponding technical documents appended. Any addition of additives or wetting agents will be subject to written authorisation from the Contracting Authority. The use of additives with resin systems is known in many cases to prejudice the required mechanical and electrical properties, in particular the irradiation stability. Dilutants, fillers, plasticisers and flexibilisers are therefore specifically prohibited. Details of bonding and curing operations for the resin system must be submitted at the tendering stage. The Contracting Authority will approve all materials and processes prior to use in coil manufacture, but such approval shall in no way release the manufacturing company from any of its responsibilities under the contract. The coil terminals, the connection posts and all metallic parts connected to them will be insulated from the yoke and able to sustain 5 kV DC without any electrical breakdown and with an insulation resistance greater than 10 MΩ. The coil terminals, the connection posts and all metallic parts connected to them will be protected against accidental contact by an insulating, transparent cover, shielded against contact to IP2X, which can only be removed by the use of tools; the Bidder’s proposals for this cover shall be described in the offer. Magnet electrical termination connectors are to be decided in conjunction with the Contracting Authority once the overall magnet design has been finalised. A single terminal connection post able to receive a 10 mm² cable shall be provided for earthing the yoke and other components. This shall be connected to all laminations (if used) in each block comprising the yoke by means of a single, resistive, conducting strip painted along the yoke block. This shall be designed so as not to create a shorted turn around the yoke laminations.
AutoNDA by SimpleDocs

Related to Bonding and Outer-insulation System

  • Unbundled Sub-Loop Concentration System (USLC 2.9.1 Where facilities permit and where necessary to comply with an effective Commission order, BellSouth will provide <<customer_name>> with the ability to concentrate its sub-loops onto multiple DS1s back to the BellSouth Central Office. The DS1s will then be terminated into <<customer_name>>’s collocation space. TR-008 and TR303 interface standards are available.

  • Irrigation Systems The Project Area either has no irrigation system or a low-volume drip irrigation system. If a watering system is used, it is a drip irrigation system equipped with a filter, pressure regulator and emitters rated at twenty (20) gallons per hour (gph) or less. The system is maintained free of leaks and malfunctions. No spray irrigation is applied to the Project Area, including spray from irrigation systems adjacent to the Project Area.

  • Contractor’s Pollution Liability Insurance If specified in Schedule A, the Contractor shall maintain, or cause the Subcontractor doing such Work to maintain, Contractors Pollution Liability Insurance covering bodily injury and property damage. Such insurance shall provide coverage for actual, alleged or threatened emission, discharge, dispersal, seepage, release or escape of pollutants (including asbestos), including any loss, cost or expense incurred as a result of any cleanup of pollutants (including asbestos) or in the investigation, settlement or defense of any claim, action, or proceedings arising from the operations under this Contract. Such insurance shall be in the Contractor’s name and list the City as an Additional Insured and any other entity specified in Schedule A. Coverage shall include, without limitation, (a) loss of use of damaged property or of property that has not been physically injured, (b) transportation, and (c) non-owned disposal sites.

  • Contractors Pollution Liability Insurance (If Applicable $1,000,000 per occurrence and $2,000,000 aggregate or whatever amount is acceptable to the City for any exposure to “hazardous materials” as this term is defined in applicable law, including but not limited to waste, asbestos, fungi, bacterial or mold. Lower tier sub-subcontractors, Truckers, Suppliers: Evidence confirming lower tier subcontractors, truckers and suppliers are maintaining valid insurance prior to beginning work on the project to meet the requirements set forth herein on Subcontractor, including but not limited to all additional insured requirements of Subcontractor. ALL COVERAGES Coverage shall not be suspended, voided, canceled, or non-renewed by either CONTRACTOR or by the insurer, reduced in coverage or in limits except after thirty (30) days' prior written notice has been given to CITY except for ten (10) days’ notice for nonpayment of premium.

  • SHIPPING AND AIR TRANSPORT 1. Profits of an enterprise of a Contracting State from the operation of ships or aircraft in international traffic shall be taxable only in that State.

  • Pollution Liability Insurance 15.1.6.1 Developer shall procure and maintain Pollution Liability Insurance that shall protect Developer, District, Construction Manager(s), Project Inspector(s), and Architect(s) from all claims for bodily injury, property damage, including natural resource damage, cleanup costs, removal, storage, disposal, and/or use of the pollutant arising from operations under this Facilities Lease, and defense, including costs and expenses incurred in the investigation, defense, or settlement of claims. Coverage shall apply to sudden and/or gradual pollution conditions resulting from the escape or release of smoke, vapors, fumes, acids, alkalis, toxic chemicals, liquids, or gases, natural gas, waste materials, or other irritants, contaminants, or pollutants, including asbestos. This coverage shall be provided in a form at least as broad as Insurance Services Offices, Inc. (ISO) Form CG 2415, or Developer shall procure and maintain these coverages separately.

  • Reactive Power and Primary Frequency Response 9.6.1 Power Factor Design Criteria

  • Fire Fighting Costs of operating and maintaining the fire-fighting equipments and personnel, if any.

  • CLEAN AIR AND WATER POLLUTION CONTROL ACT Customer Purchase Orders using federal funds must contain a provision that requires the Contractor to agree to comply with all applicable standards, orders or regulations issued pursuant to the Clean Air Act (42 U.S.C. 7401-7671q) and the Federal Water Pollution Control Act as amended (33 U.S.C. 1251-1387). Violations must be reported to the Federal awarding agency and the Regional Office of the Environmental Protection Agency (EPA). Pursuant to the Federal Rule above, Contractor certifies that it is in compliance with all applicable provisions of the Clean Air Act (42 U.S.C. 7401-7671q) and the Federal Water Pollution Control Act as amended (33 U.S.C. 1251-1387) and will remain in compliance during the term of the Contract.

  • Commercial General Liability and Business Auto Liability will be endorsed to provide primary and non-contributory coverage The Commercial General Liability Additional Insured endorsement will include on-going and completed operations and will be submitted with the

Time is Money Join Law Insider Premium to draft better contracts faster.