Control & Instrumentation Sample Clauses

Control & Instrumentation. The existing plant unit control system is the Siemens Teleperm C/Iskamatic B on units 5 and 4, and the Siemens T3000 on unit 6. The precipitator plant functions independent of the unit control system as it is equipped with a standalone Precipitator Plant Management System (PPMS) SCADA system for operation, monitoring, control, configuration, data storage and alarming purposes of the electrostatic precipitator plants. Refurbishment of units 5 and 4 to similar technology as unit 6 is planned and will be a separate project to the HFPS project. The high level control architecture of the electrostatic precipitator plant control system of units 5 & 4 and unit 6 is depicted in figures 4 and 5 respectively below and consists primarily of the MCS II controllers (unit 5 also includes HFPS technology of controllers) and PPMS. The PPMS provides for Human Machine Interface to the precipitator MCS II field controllers and allows for the remote engineering and configuration, operation, control, monitoring, alarming, data storage and historical trending of the precipitator plants. The PPMS is an Ethernet network consisting of the communication network layer comprised of APPLICOM Gateway and associated network infrastructure such as network switches and media converters, as well as the application system layer comprised of ClearSCADA SCADA system of Server and Client and provides for Engineering and Operator interface to the precipitator field controllers. Unit 5 has been fitted with HFP’s in the first three fields during which the communication gateway has been changed from APPLICOM gateway to the Sixnet IPM PLC. Furthermore the local display of the HFPS units have been removed from the ESP roof and mounted in the respective ESP field MCSII panel in the ESP substation. The communication protocol between the gateway and the SCADA server is Modbus TCP for all three units. The PPMS SCADA consists of a single server located in the server room situated in the 2nd floor of the station admin building and the individual clients are located in the control room of each unit. The SCADA system is based on object data base and as a result changes to symbols, mimics and other objects can be made online and into effect without the need for compiling and restarting. Five special functions are available from the PPMS SCADA system and include automatic start-up and shut- down, automatic programme selection, power off raping and high xxxxxx level protection. The MCS II controller is a micro...
AutoNDA by SimpleDocs

Related to Control & Instrumentation

  • Instrumentation The acceleration shall be recorded during the test, using equipment in accordance with channel frequency class 1000 as specified in the latest version of ISO 6487.

  • Documentation control Specify how documentation will be identified with an alpha numeric which indicates source, recipient, communication number etc. Provide details of any particular format or other constraints; for example that all contractual communications will be in the form of properly compiled letters or forms attached to e mails and not as a message in the e mail itself. State any particular routing requirements but note from TSC3 who issues what to whom.

  • Documentation License Subject to the terms of this Agreement, Flock hereby grants to Customer a non-exclusive, non-transferable right and license to use the Documentation during the Service Term for Customer’s internal purposes in connection with its use of the Flock Services as contemplated herein.

  • Supporting Documentation Upon request, the HSP will provide the LHIN with proof of the matters referred to in this Article.

  • AGREEMENT NOT TRANSFERRABLE TO OTHER FACILITIES This agreement is valid for only the residential facilities assigned to the Student. This agreement cannot be transferred, nor can it be converted to any other type of lease or agreement without a written or electronically reproducible modification agreement submitted by the student and approved by the Executive Director or the Executive Director’s designee. There is no reciprocity of housing agreements with any other housing organization or complex, including but not limited to on-campus residence halls, on-campus apartments, Rosen, Towers, Northview, UCF affiliated housing, fraternity-sorority housing, or any other housing, residential, and/or apartment facilities both on- and off-campus. MOVE IN, RESIDENCE, MOVE OUT

  • Project Documentation All documentation provided to the City other than Project drawings shall be furnished on a Microsoft compatible compact disc.

  • Medical Documentation The teacher must supply a letter from a medical 3 doctor, who treated the patient, stating that in his/her opinion, there is a strong 4 probability that the illness was contracted at school.

  • Required Fiscal Documentation A. Prior to execution of this Agreement, Contractor will have submitted to County for review and approval an annual budget covering all contracted services under this Agreement.

  • Licensed Documentation If commercially available, Licensee shall have the option to require the Contractor to deliver, at Contractor’s expense: (i) one (1) hard copy and one (1) master electronic copy of the Documentation in a mutually agreeable format; (ii) based on hard copy instructions for access by downloading from the Internet

  • Options for Documentation 6.1. We shall document and, upon request, provide such documentation of Our compliance with the obligations agreed upon in this DPA by appropriate measures.

Time is Money Join Law Insider Premium to draft better contracts faster.