DELIVERY POINT AND FACILITIES Sample Clauses

DELIVERY POINT AND FACILITIES. Delivery of natural gas by the Utility shall be to the Customer’s site at 0000 X. Xxxxxxx Avenue, Xxxxxxxx, Arizona in a mutually agreeable location to serve the maximum operational load requirement of 200,000 CFH at a minimum of one hundred - twenty-five (125) psig. The Utility will construct a Steel main approximately 1,135 feet in length (referred to as the “Main”) from existing facilities; a Steel service line; and a meter set assembly with pressure regulation. Collectively, the pipe, meter set assemblies, service lines, regulators and other appurtenant devices generally described above are the “Incremental Natural Gas Facilities” that are the subject of this Agreement. Should the Customer request higher delivery pressure or an hourly flow rate greater than what is specified by Customer in this Agreement for the Peak Load Requirement, the Utility may need to construct additional facilities under a separate agreement. Extension and construction of any additional facilities shall be made in accordance with Utility’s Tariff in effect at the time of the Customer’s requested increase in pressure or hourly flow rates. It is the responsibility of the Customer to initiate said request to the Utility.
AutoNDA by SimpleDocs
DELIVERY POINT AND FACILITIES. Delivery of natural gas by the Utility shall be to the Customer's site at 0000 Xxxxx Xxxx, Las Vegas, Nevada in a mutually agreeable location. Customer intends to construct a water reclamation facility at the specified location. The Peak Load Requirement for the facility is 2,760 cfh at 2 psig. To serve the Peak Load Requirement of this water reclamation facility, Utility will replace approximately 1,050 feet of 2" PE with 4" PE on Xxxxxx Boulevard originating at Cheyenne Avenue and proceeding south; install approximately 1055 feet of 4" PE on Xxxxx from Xxxxxx Boulevard to the project site; and install a service line and a meter set assembly. Collectively, these are the Incremental Natural Gas Facilities that are the subject of this Agreement. If Customer requires additional pressure or an hourly flow rate higher than what is specified by Customer in this Agreement for the Peak Load Requirement, the Utility may need to construct additional facilities. Extension and construction of any additional facilities shall be made in accordance with Rule 9 of Utility’s Nevada Gas Tariff in effect at the time of the Customer’s requested increase in pressure or hourly flow rates. It is the responsibility of the Customer to initiate said request from the Utility.

Related to DELIVERY POINT AND FACILITIES

  • Delivery Points ‌ Project water made available to the Agency pursuant to Article 6 shall be delivered to the Agency by the State at the delivery structures established in accordance with Article 10.

  • Delivery Point (a) All Energy shall be Delivered hereunder by Seller to Buyer at the Delivery Point. Seller shall be responsible for the costs of delivering its Energy to the Delivery Point consistent with all standards and requirements set forth by the FERC, ISO-NE, the Interconnecting Utility and any other applicable Governmental Entity and any applicable tariff.

  • STORAGE TANKS AND SUMPS 3.1 Is any above or below ground storage of gasoline, diesel, petroleum, or other Hazardous Materials in tanks or sumps proposed in, on or about the Premises? Existing Tenants should describe any such actual or proposed activities. Yes [ ] No [ ] If yes, please explain:

  • Working Facilities During the Term of Employment, the Company shall furnish the Executive with an office, secretarial help and such other facilities and services suitable to his position and adequate for the performance of his duties hereunder.

  • Interconnection 2.1.10 Startup Testing and Commissioning

  • Location and Facilities The Executive will be furnished with the working facilities and staff customary for executive officers with the title and duties set forth in Section 1 and as are necessary for him to perform his duties. The location of such facilities and staff shall be at the principal administrative offices of the Company and the Bank, or at such other site or sites customary for such offices.

  • Parking Facilities Alamo Colleges District shall make the existing parking facilities at the rented Facility available for the vehicular traffic and parking necessitated by the Organization’s Use of the rented Facility, on a non-exclusive basis, as specified at Exhibit A. MAXIMUM CAPACITY. Organization anticipates approximately the number of participants stated at Exhibit A and agrees to inform Alamo Colleges District of any significant changes five (5) business days in advance of a Use. Organization shall not admit a larger number of persons than can safely and freely move about the Facility. Alamo Colleges District shall notify Organization of the recommended capacity of the Facility and all decisions of Alamo Colleges District concerning questions arising under this Paragraph shall be final.

  • Plant and Equipment The plants, structures and ------------------- equipment of the Company are structurally sound with no known defects and are in good operating condition and repair and are adequate for the uses to which they are being put. None of such plants, structures or equipment are in need of maintenance or repairs except for ordinary, routine maintenance and repairs which are not material in nature or cost. The Company has not received notification that it is in violation of any applicable building, zoning, anti- pollution, health or other law, ordinance or regulation in respect of its plants or structures or their operations.

Time is Money Join Law Insider Premium to draft better contracts faster.