Design Specific Examples Sample Clauses

Design Specific Examples. ‌ Con Xxxxxx’s Central Engineering specification CE-ES-2002 provides the following checklist for Transmission Substation Design: ▪ Primary and secondary voltage to be used ▪ System studies ▪ Substation capacity, current and future ▪ Future expansion needs ▪ BIL rating of equipment ▪ Number of transmission feeder positions, initial and final ▪ Size and layout of station property ▪ Air insulated versus SF6 bus (Momentary rating of bus) ▪ Maintenance requirements including equipment testing ▪ Electrical clearances ▪ Light and power requirements including Standby Diesel Generator and Mobile Generator Quick Connect requirements ▪ Grounding design ▪ Control room layout ▪ 125 VDC system requirements ▪ Cable and trench layout ▪ Metering scheme ▪ Roadway layout ▪ Primary and secondary voltage relaying schemes ▪ Aesthetic appearance of station ▪ Type of primary transmission cables ▪ One-line high tension drawing ▪ Accuracies of current transformersLighting designSecurity protection ▪ Type of structure ▪ Number and location of shunt/series reactors ▪ Environmental aspects, Oil Water Separator sizing and location ▪ Type of circuit switchers and interrupters (Interrupting rating) ▪ Type of metal clad switchgear Transformer MVA rating and % impedance ▪ Circuit breaker ratings (Continuous and short circuit) ▪ Phase angle regulators ▪ Bus configuration (Ring or breaker and half ▪ Automation / SCADA / HMI, Alarms requirements ▪ Communications / IR requirements ▪ Spare parts inventory assessment ▪ Lightning / Surge protectionCorporate Security, Cyber Security While the NYISO’s Large Facility Interconnection procedures do not specifically address these, Con Edison requires all tasks above to be completed before the substation configuration can be accepted as final.
AutoNDA by SimpleDocs

Related to Design Specific Examples

  • Implementation Specifications 1. The accounting shall contain the date, nature, and purpose of such disclosures, and the name and address of the person or agency to whom the disclosure is made.

  • Technical Specification As enumerated in Special Conditions of Contract/Scope of Work/attached Drawing/ Details/Schedule of Rates.

  • DAF Specifications Developer shall submit initial specifications for the DAF, including System Protection Facilities, to Connecting Transmission Owner and NYISO at least one hundred eighty (180) Calendar Days prior to the Initial Synchronization Date; and final specifications for review and comment at least ninety (90) Calendar Days prior to the Initial Synchronization Date. Connecting Transmission Owner and NYISO shall review such specifications to ensure that the DAF are compatible with the technical specifications, operational control, and safety requirements of the Connecting Transmission Owner and NYISO and comment on such specifications within thirty (30) Calendar Days of Developer’s submission. All specifications provided hereunder shall be deemed to be Confidential Information.

  • Project Specific Milestones In addition to the milestones stated in Section 212.5 of the Tariff, as applicable, during the term of this ISA, Interconnection Customer shall ensure that it meets each of the following development milestones:

  • Technical Specifications The Technical Specifications furnished on the CD are intended to establish the standards for quality, performance and technical requirements for all labor, workmanship, material, methods and equipment necessary to complete the Work. When specifications and drawings are provided or referenced by the County, these are to be considered part of the Scope of Work, and to be specifically documented in the Detailed Scope of Work. For convenience, the County supplied specifications, if any, and the Technical Specifications furnished on the CD.

  • Service Specification The Parties have agreed upon the scope and specification of the Services provided under this Service Agreement in the Service Specification.

  • Schematic Design Phase Services § 3.2.1 The Architect shall review the program and other information furnished by the Owner, and shall review laws, codes, and regulations applicable to the Architect’s services.

  • Class Specifications The Human Resources Division shall determine:

  • Billing Specifications 55.6.1 The Parties agree that billing requirements and outputs will be consistent with the Ordering & Billing Form (OBF) and also with Telcordia Technologies Billing Output Specifications (BOS).

  • Escrow Format Specification 3.1. Deposit’s Format. Registry objects, such as domains, contacts, name servers, registrars, etc. will be compiled into a file constructed as described in draft-xxxxx-xxxxxxx-registry-data-escrow, see Part A, Section 9, reference 1 of this Specification and draft-xxxxx-xxxxxxx-dnrd-objects-mapping, see Part A, Section 9, reference 2 of this Specification (collectively, the “DNDE Specification”). The DNDE Specification describes some elements as optional; Registry Operator will include those elements in the Deposits if they are available. If not already an RFC, Registry Operator will use the most recent draft version of the DNDE Specification available at the Effective Date. Registry Operator may at its election use newer versions of the DNDE Specification after the Effective Date. Once the DNDE Specification is published as an RFC, Registry Operator will implement that version of the DNDE Specification, no later than one hundred eighty (180) calendar days after. UTF-8 character encoding will be used.

Time is Money Join Law Insider Premium to draft better contracts faster.