Gravimetric Method Sample Clauses

Gravimetric Method. 3.3.1. Metering a limited quantity of pure gas (CO or C3H8) by means of a gravimetric technique 3.3.2. The following gravimetric procedure may be used to verify the CVS system. The weight of a small cylinder filled with either carbon monoxide or propane is determined with a precision of ±0.
Gravimetric Method. 3.3.1. Metering a limited quantity of pure gas (CO or C3H8) by means of a gravimetric technique. 3.3.2. The following gravimetric procedure may be used to verify the CVS system. The weight of a small cylinder filled with either carbon monoxide or propane is determined with a precision of ± 0.01 g. For about 5 to 10 minutes, the CVS system is operated as in a normal exhaust emission test, while CO or propane is injected into the system. The quantity of pure gas involved is determined by means of differential weighing. The gas accumulated in the bag is then analysed by means of the equipment normally used for exhaust-gas analysis. The results are then compared to the concentration figures computed previously.
Gravimetric Method extraordinary events such as bushfires, prescribed burning, dust storms, sea fog, fire incidents or any other activity agreed by the Secretary. e “Reasonable and feasible avoidance measures” includes, but is not limited to, the operational requirements in conditions 14, 15 and 16 to develop and implement an air quality management system that ensures operational responses to the risks of exceedance of the criteria.
Gravimetric Method. Metering a limited quantity of pure gas (CO or C3H8) by means of a gravimetric technique.

Related to Gravimetric Method

  • SHOP XXXXXXX (a) The Union may elect or appoint a Shop Xxxxxxx or Shop Stewards to represent the employees and the Union shall notify the Company as to the name or names of such Shop Xxxxxxx or Shop Stewards. The Company agrees that no Shop Xxxxxxx shall suffer any discrimination by reason of holding such office. (b) When the Company for any reason finds it necessary to layoff or terminate a Shop Xxxxxxx, the Business Representative of the Union shall be notified prior to such termination.

  • Measurement method An isolation resistance test instrument is connected between the live parts and the electrical chassis. The isolation resistance is subsequently measured by applying a DC voltage at least half of the working voltage of the high voltage bus. If the system has several voltage ranges (e.g. because of boost converter) in conductively connected circuit and some of the components cannot withstand the working voltage of the entire circuit, the isolation resistance between those components and the electrical chassis can be measured separately by applying at least half of their own working voltage with those components disconnected.