NONPAYMENT AND PROCEDURES FOR DISCONNECTION 12.1 If a Party is furnished Interconnection Services under the terms of this Agreement in more than one (1) state, Section 12.2 below through Section 12.19 below, inclusive, shall be applied separately for each such state. 12.2 Failure to pay charges shall be grounds for disconnection of Interconnection Services furnished under this Agreement. If a Party fails to pay any charges billed to it under this Agreement, including but not limited to any Late Payment Charges or Unpaid Charges, and any portion of such Unpaid Charges remain unpaid after the Bill Due Date, the Billing Party will send a Discontinuance Notice to such Non-Paying Party. The Non-Paying Party must remit all Unpaid Charges to the Billing Party within fifteen (15) calendar days of the Discontinuance Notice. 12.3 AT&T-21STATE will also provide any written notification to any Commission as required by any State Order or Rule. 12.4 If the Non-Paying Party desires to dispute any portion of the Unpaid Charges, the Non-Paying Party must complete all of the following actions not later than fifteen (15) calendar days following receipt of the Billing Party’s notice of Unpaid Charges: 12.4.1 notify the Billing Party in writing which portion(s) of the Unpaid Charges it disputes, including the total Disputed Amounts and the specific details listed in Section 13.4 below of this Agreement, together with the reasons for its dispute; and 12.4.2 pay all undisputed Unpaid Charges to the Billing Party; and 12.4.3 pay all Disputed Amounts (other than Disputed Amounts arising from Intercarrier Compensation) into an interest bearing escrow account that complies with the requirements set forth in Section 11.10 above; and 12.4.4 furnish written evidence to the Billing Party that the Non-Paying Party has established an interest bearing escrow account that complies with all of the terms set forth in Section 11.10 above and deposited a sum equal to the Disputed Amounts into that account (other than Disputed Amounts arising from Intercarrier Compensation). Until evidence that the full amount of the Disputed Charges (other than Disputed Amounts arising from Intercarrier Compensation) has been deposited into an escrow account that complies with Section
GROUNDS FOR DIVORCE This Agreement shall remain in effect only if the grounds for Divorce are due to the following: (check all that apply)
Disconnection Upon termination of this Agreement, Developer and Connecting Transmission Owner will take all appropriate steps to disconnect the Developer’s Large Generating Facility from the New York State Transmission System. All costs required to effectuate such disconnection shall be borne by the terminating Party, unless such termination resulted from the non-terminating Party’s Default of this Agreement or such non-terminating Party otherwise is responsible for these costs under this Agreement.
DISCONNECTION OF SUPPLY 14.1 When can we arrange for disconnection? (a) you do not pay your bill by the pay-by date and, if you are a residential customer, you: (i) fail to comply with the terms of an agreed payment plan; or (ii) do not agree to an offer to pay the bill by instalments, or having agreed, you fail to comply with the instalment arrangement; (b) you do not provide a security deposit we are entitled to require from you; or (c) you do not give access to your premises to read a meter (where relevant) for 3 consecutive meter reads; or (d) you fail to give us safe and unhindered access to the premises as required by clause 11 or any requirements under the energy laws; or (e) there has been illegal or fraudulent use of energy at your premises in breach of clause 16 of this contract; or (f) we are otherwise entitled or required to do so under the Rules or by law.
Temporary Disconnection Temporary disconnection shall continue only for so long as reasonably necessary under Good Utility Practice.
Reconnection The Parties shall cooperate with each other to restore the Small Generating Facility, Interconnection Facilities, and the New York State Transmission System and Distribution System to their normal operating state as soon as reasonably practicable following a temporary disconnection.
Downtime There may be downtime during the Migration. The duration of the downtime will depend on the amount of data that Agency is migrating. Axon will work with Agency to minimize any downtime. Any VIEVU mobile application will need to be disabled upon Migration.
Planned Outages Seller shall schedule Planned Outages for the Project in accordance with Good Industry Practices and with the prior written consent of Buyer, which consent may not be unreasonably withheld or conditioned. The Parties acknowledge that in all circumstances, Good Industry Practices shall dictate when Planned Outages should occur. Seller shall notify Buyer of its proposed Planned Outage schedule for the Project for the following calendar year by submitting a written Planned Outage schedule no later than October 1st of each year during the Delivery Term. The Planned Outage schedule is subject to Buyer’s approval, which approval may not be unreasonably withheld or conditioned. Buyer shall promptly respond with its approval or with reasonable modifications to the Planned Outage schedule and Seller shall use its best efforts in accordance with Good Industry Practices to accommodate Xxxxx’s requested modifications. Notwithstanding the submission of the Planned Outage schedule described above, Seller shall also submit a completed Outage Notification Form to Buyer no later than fourteen (14) days prior to each Planned Outage and all appropriate outage information or requests to the CAISO in accordance with the CAISO Tariff. Seller shall contact Buyer with any requested changes to the Planned Outage schedule if Seller believes the Project must be shut down to conduct maintenance that cannot be delayed until the next scheduled Planned Outage consistent with Good Industry Practices. Seller shall not change its Planned Outage schedule without Buyer’s approval, not to be unreasonably withheld or conditioned. Seller shall use its best efforts in accordance with Good Industry Practices not to schedule Planned Outages during the months of July, August, September and October. At Buyer’s request, Seller shall use commercially reasonable efforts to reschedule Planned Outage so that it may deliver Product during CAISO declared or threatened emergency periods. Seller shall not substitute Energy from any other source for the output of the Project during a Planned Outage.
Interconnection Customer Drawings Within one hundred twenty (120) days after the date of Initial Operation, unless the Interconnection Parties agree on another mutually acceptable deadline, the Interconnection Customer shall deliver to the Transmission Provider and the Interconnected Transmission Owner final, “as-built” drawings, information and documents regarding the Customer Interconnection Facilities, including, as and to the extent applicable: a one-line diagram, a site plan showing the Customer Facility and the Customer Interconnection Facilities, plan and elevation drawings showing the layout of the Customer Interconnection Facilities, a relay functional diagram, relaying AC and DC schematic wiring diagrams and relay settings for all facilities associated with the Interconnection Customer's step-up transformers, the facilities connecting the Customer Facility to the step-up transformers and the Customer Interconnection Facilities, and the impedances (determined by factory tests) for the associated step-up transformers and the Customer Facility. As applicable, the Interconnection Customer shall provide Transmission Provider and the Interconnected Transmission Owner specifications for the excitation system, automatic voltage regulator, Customer Facility control and protection settings, transformer tap settings, and communications.
Reduction and Disconnection NYISO or Connecting Transmission Owner may reduce Energy Resource Interconnection Service and Capacity Resource Interconnection Service or disconnect the Large Generating Facility or the Developer Attachment Facilities, when such reduction or disconnection is necessary under Good Utility Practice due to an Emergency State. These rights are separate and distinct from any right of Curtailment of NYISO pursuant to the NYISO OATT. When NYISO or Connecting Transmission Owner can schedule the reduction or disconnection in advance, NYISO or Connecting Transmission Owner shall notify Developer of the reasons, timing and expected duration of the reduction or disconnection. NYISO or Connecting Transmission Owner shall coordinate with the Developer using Good Utility Practice to schedule the reduction or disconnection during periods of least impact to the Developer and the New York State Transmission System. Any reduction or disconnection shall continue only for so long as reasonably necessary under Good Utility Practice. The Parties shall cooperate with each other to restore the Large Generating Facility, the Attachment Facilities, and the New York State Transmission System to their normal operating state as soon as practicable consistent with Good Utility Practice.