In-Situ Dry Density Control Sample Clauses

In-Situ Dry Density Control. The test shall be carried out using the sand-cone method or the rubber-balloon method or nuclear density and/or moisture method as directed by the Engineer. In case the nuclear densometer is used, at each test location the average of four readings taken at positions rotated by 90 will be used. A check/comparison test using the sand replacement method (sand cone or the rubber balloon test methods) will be carried out at a 50 test interval. Initial calibration of the instrument will be done by carrying out at least fifty tests in parallel with the sand replacement method for each different material encountered. The check tests will be used to update the initial calibration of the instrument. The instrument shall have a valid calibration certificate before the initial site calibration mentioned above is carried out.
AutoNDA by SimpleDocs

Related to In-Situ Dry Density Control

  • Availability Control Personal Data will be protected against accidental or unauthorized destruction or loss. Measures: • SAP employs regular backup processes to provide restoration of business-critical systems as and when necessary. • SAP uses uninterrupted power supplies (for example: UPS, batteries, generators, etc.) to protect power availability to the Data Centers. • SAP has defined business contingency plans for business-critical processes and may offer disaster recovery strategies for business critical Services as further set out in the Documentation or incorporated into the Order Form for the relevant Cloud Service. • Emergency processes and systems are regularly tested.

  • Loop Provisioning Involving Integrated Digital Loop Carriers 2.6.1 Where InterGlobe has requested an Unbundled Loop and BellSouth uses IDLC systems to provide the local service to the End User and BellSouth has a suitable alternate facility available, BellSouth will make such alternative facilities available to InterGlobe. If a suitable alternative facility is not available, then to the extent it is technically feasible, BellSouth will implement one of the following alternative arrangements for InterGlobe (e.g. hairpinning):

  • Quality control system (i) The Contractor shall establish a quality control mechanism to ensure compliance with the provisions of this Agreement (the “Quality Assurance Plan” or “QAP”).

  • Supervisory Control and Data Acquisition (SCADA) Capability The wind plant shall provide SCADA capability to transmit data and receive instructions from the ISO and/or the Connecting Transmission Owner for the Transmission District to which the wind generating plant will be interconnected, as applicable, to protect system reliability. The Connecting Transmission Owner for the Transmission District to which the wind generating plant will be interconnected and the wind plant Developer shall determine what SCADA information is essential for the proposed wind plant, taking into account the size of the plant and its characteristics, location, and importance in maintaining generation resource adequacy and transmission system reliability in its area.

  • Quality Control A. Controlled Affiliate agrees to use the Licensed Marks and Name only in connection with the licensed services and further agrees to be bound by the conditions regarding quality control shown in attached Exhibit A as they may be amended by BCBSA from time-to-time.

  • Horizontal Movement The Board encourages all unit members to improve their skills through advanced training and, as an inducement thereto, provides extra compensation for those who do so successfully. The Board delegates to the Superintendent the responsibility for assuring that unit members comply with the following regulations when claiming credit for advanced studies.

  • Direct Trunked Transport 7.3.2.1 Either Party may elect to purchase direct trunked transport from the other Party.

  • Infection Control Consistent with the Centers for Disease Control and Prevention Guideline for Infection Control in Health Care Personnel, and University Policy 3364-109-EH-603, the parties agree that all bargaining unit employees who come in contact with patients in the hospital or ambulatory care clinics will need to be vaccinated against influenza when flu season begins each fall. The influenza vaccine will be offered to all health care workers, including pregnant women, before the influenza season, unless otherwise medically contraindicated or it compromises sincerely held religious beliefs.

  • Local Switching Interfaces 4.2.13.1 Newcomm shall order ports and associated interfaces compatible with the services it wishes to provide as listed in Exhibit A. BellSouth shall provide the following local switching interfaces:

  • Collocation of Switching Equipment CLEC may collocate any equipment that is necessary for Interconnection or access to Unbundled Network Elements.

Time is Money Join Law Insider Premium to draft better contracts faster.