Site Calibration Sample Clauses

Site Calibration. In case Site Calibration revealed to be necessary according to the conclusions of 5.2.2 of this Part J-2-A, the IE will perform that Site Calibration in accordance to Annex C of [Ref.1] for each of the TWT requiring it. The Site Calibration works, involving the installation of met mast/s in the position of the TWT, will be scheduled in a manner that does not interfere on the civil works of the wind farm. The IE will propose a detailed schedule for the acceptance of the Parties. The IE will report periodically including information of the status of completion of the Site Calibration according to [Ref.1]. It will be aimed at the completion of representative measurement sectors which allows for the execution of the subsequent Power Curve Test in a reasonable amount of time. In case the Site Calibration must be extended for that purpose, the Parties will collaborate in the definition of the best solution which allows the completion of the measurements and causes the lowest impact on the execution of the wind farm works. The IE will issue a Site Calibration report according to [Ref.1], which will be shared between the involved parties. Regarding the procedure of site calibration, the requirements of points C.7 and C.8 of Annex C of IEC61400-12-1 Ed.2 should be met, especially the points related to: - Convergence check - Correlation check for linear regression - Change in correction between adjacent wind direction bins If these conditions are not met, the site calibration procedure will be carefully reviewed and, under consideration of the IE, uncertainties might be reviewed.
AutoNDA by SimpleDocs
Site Calibration. At least sixty (60) days prior to commencement of erection of any Wind Turbine at the Site, Owner shall cause, at its sole cost and expense, a third party engineer with significant experience in power curve testing of wind turbines who is mutually acceptable to Owner and Seller (the "Test Engineer") to complete Site Calibration pursuant to the Site Calibration Procedures described in Exhibit F. If Owner commences erection of a Wind Turbine prior to completion of the Site Calibration, the Power Curve Test shall be waived. The report and data of the Test Engineer on the Site Calibration shall be promptly delivered to Seller for its review and comment. In the event the parties cannot agree on a Test Engineer, then the Independent Engineer shall choose between the Owner's candidate and the Seller's candidate. The report and data of the Test Engineer on the Site Calibration shall be promptly delivered to Owner and Seller for their review and comment.

Related to Site Calibration

  • Testing Landlord shall have the right to conduct annual tests of the Premises to determine whether any contamination of the Premises or the Project has occurred as a result of Tenant’s use. Tenant shall be required to pay the cost of such annual test of the Premises; provided, however, that if Tenant conducts its own tests of the Premises using third party contractors and test procedures acceptable to Landlord which tests are certified to Landlord, Landlord shall accept such tests in lieu of the annual tests to be paid for by Tenant. In addition, at any time, and from time to time, prior to the expiration or earlier termination of the Term, Landlord shall have the right to conduct appropriate tests of the Premises and the Project to determine if contamination has occurred as a result of Tenant’s use of the Premises. In connection with such testing, upon the request of Landlord, Tenant shall deliver to Landlord or its consultant such non-proprietary information concerning the use of Hazardous Materials in or about the Premises by Tenant or any Tenant Party. If contamination has occurred for which Tenant is liable under this Section 30, Tenant shall pay all costs to conduct such tests. If no such contamination is found, Landlord shall pay the costs of such tests (which shall not constitute an Operating Expense). Landlord shall provide Tenant with a copy of all third party, non-confidential reports and tests of the Premises made by or on behalf of Landlord during the Term without representation or warranty and subject to a confidentiality agreement. Tenant shall, at its sole cost and expense, promptly and satisfactorily remediate any environmental conditions identified by such testing in accordance with all Environmental Requirements. Landlord’s receipt of or satisfaction with any environmental assessment in no way waives any rights which Landlord may have against Tenant.

  • Commissioning Commissioning tests of the Interconnection Customer's installed equipment shall be performed pursuant to applicable codes and standards. If the Interconnection Customer is not proceeding under Section 2.3.2, the Utility must be given at least ten (10) Business Days written notice, or as otherwise mutually agreed to by the Parties, of the tests and may be present to witness the commissioning tests.

  • Sampling The Licensee agrees that the Composition is purchased as a “Work Made for Hire” whereby the clearing of any sampled materials is the responsibility of Licensee.

  • Technical Specifications The Technical Specifications furnished on the CD are intended to establish the standards for quality, performance and technical requirements for all labor, workmanship, material, methods and equipment necessary to complete the Work. When specifications and drawings are provided or referenced by the County, these are to be considered part of the Scope of Work, and to be specifically documented in the Detailed Scope of Work. For convenience, the County supplied specifications, if any, and the Technical Specifications furnished on the CD.

  • Configuration The configuration for the Purchase Right Aircraft will be the Detail Specification for Model 767-3S2F aircraft at the revision level in effect at the time of the Supplemental Agreement. Such Detail Specification will be revised to include (i) changes required to obtain required regulatory certificates and (ii) other changes as mutually agreed upon by Boeing and Customer.

  • Engineering Forest Service completed survey and design for Specified Roads prior to timber sale advertisement, unless otherwise shown in A8 or Purchaser survey and design are specified in A7. On those roads for which Forest Service completes the design during the contract, the design quantities shall be used as the basis for revising estimated costs stated in the Schedule of Items and adjusting Timber Sale Account. Forest Service engineering shall be completed according to the schedule in A8. Should Forest Service be unable to perform the designated survey and design by the completion date or other agreed to time, upon written agreement, Purchaser shall assume responsibility for such work. In such event, Contracting Officer shall revise:

  • Acceptance Testing At the time of installation of a LIS trunk group, and at no additional charge, acceptance tests will be performed to ensure that the service is operational and meets the applicable technical parameters.

  • Engineering Services Definition: Engineering Services includes any service or creative work, the adequate performance of which requires education, training and experience in the application of special knowledge in consulting, investigating, evaluating, planning and designing, engineering principles. Engineering Services covered by the Xxxxxx Architect-Engineers Act (40 U.S.C. 1102) are not covered in the primary scope of OASIS SB. Examples: Service areas that are included under the Engineering Services discipline include, but are not limited to the following:

  • Project Schedule Construction must begin within 30 days of the date set forth in Appendix A, Page 2, for the start of construction, or this Agreement may become null and void, at the sole discretion of the Director. However, the Recipient may apply to the Director in writing for an extension of the date to initiate construction. The Recipient shall specify the reasons for the delay in the start of construction and provide the Director with a new start of construction date. The Director will review such requests for extensions and may extend the start date, providing that the Project can be completed within a reasonable time frame.

  • Reverse Engineering The Customer must not reverse assemble or reverse compile or directly or indirectly allow or cause a third party to reverse assemble or reverse compile the whole or any part of the software or any products supplied as a part of the Licensed System.

Time is Money Join Law Insider Premium to draft better contracts faster.