Load Connection Study Sample Clauses

Load Connection Study. Unless otherwise mutually agreed, AEP shall respond within ten (10) Business Days of receipt of such a request and, if necessary, provide a Load Connection Study (“LCS”) Agreement and a list of any additional information that AEP would require from the Customer to proceed with such study. Unless otherwise agreed, the LCS Agreement shall commit the Customer to pay AEP the actual cost to complete the study and make an advance deposit equal to the estimated study cost or $25,000, which ever is less. The Customer shall execute and deliver the LCS Agreement and required deposit to AEP within thirty (30) Calendar Days following its receipt. Upon receipt of the executed study agreement, study data as requested above, and the required deposit, AEP shall carry out the LCS. In the LCS, AEP shall assess the feasibility of modifying an existing Delivery Point or establishing the new Delivery Point using power flow and short circuit analyses and any other analyses that may be appropriate. It shall also determine the details and estimated cost of facilities necessary for establishing the requested Delivery Point and any system additions/upgrades needed to address any problems identified in the LCS. If the Customer fails to return an executed LCS Agreement and required deposit within thirty (30) Calendar Days of receipt or at a later date as the Parties may mutually agree, AEP Operating Companies of the Original Sheet No. 23 American Electric Power System FERC Electric Tariff, Third Revised Volume No. 6 shall deem the study request to be withdrawn. The Customer may withdraw its study request at any time by written notice of such withdrawal to AEP.
AutoNDA by SimpleDocs
Load Connection Study. Unless otherwise mutually agreed, AEP shall respond within ten (10) Business Days of receipt of such a request and, if necessary, provide a Load Connection Study (“LCS”) Agreement and a list of any additional information that AEP would require from the Customer to proceed with such study. Unless otherwise agreed, the LCS Agreement shall commit the Customer to pay AEP the actual cost to complete the study and make an advance deposit equal to the estimated study cost or $25,000, which ever is less. The Customer shall execute and deliver the LCS Agreement and required deposit to AEP within thirty (30) Calendar Days following its receipt. Upon receipt of the executed study agreement, study data as requested above, and the required deposit, AEP shall carry out the LCS. In the LCS, AEP shall assess the feasibility of modifying an existing Delivery Point or establishing the new Delivery Point using power flow and short circuit analyses and any other analyses that may be appropriate. It shall also determine the details and estimated cost of facilities necessary for establishing the requested Delivery Point and any system additions/upgrades needed to address any problems identified in the LCS. If the Customer fails to return an executed LCS Agreement and required deposit within thirty

Related to Load Connection Study

  • Access Toll Connecting Trunk Group Architecture 9.2.1 If CBB chooses to subtend a Verizon access Tandem, CBB’s NPA/NXX must be assigned by CBB to subtend the same Verizon access Tandem that a Verizon NPA/NXX serving the same Rate Center Area subtends as identified in the LERG.

  • Network Interconnection Architecture Each Party will plan, design, construct and maintain the facilities within their respective systems as are necessary and proper for the provision of traffic covered by this Agreement. These facilities include but are not limited to, a sufficient number of trunks to the point of interconnection with the tandem company, and sufficient interoffice and interexchange facilities and trunks between its own central offices to adequately handle traffic between all central offices within the service areas at P.01 grade of service or better. The provisioning and engineering of such services and facilities will comply with generally accepted industry methods and practices, and will observe the rules and regulations of the lawfully established tariffs applicable to the services provided.

  • By Interconnection Customer Interconnection Customer may unilaterally terminate the Interconnection Service Agreement pursuant to Applicable Laws and Regulations upon providing Transmission Provider and the Interconnected Transmission Owner sixty (60) days prior written notice thereof, provided that Interconnection Customer is not then in Default under the Interconnection Service Agreement.

  • Commissioning Commissioning tests of the Interconnection Customer's installed equipment shall be performed pursuant to applicable codes and standards. If the Interconnection Customer is not proceeding under Section 2.3.2, the Utility must be given at least ten (10) Business Days written notice, or as otherwise mutually agreed to by the Parties, of the tests and may be present to witness the commissioning tests.

  • One-Way Interconnection Trunks 2.3.1 Where the Parties have agreed to use One-Way Interconnection Trunks for the delivery of traffic from PCS to Verizon, PCS, at PCS’s own expense, shall:

  • Nyiso and Connecting Transmission Owner Authority General.‌‌ NYISO or Connecting Transmission Owner may take whatever actions with regard to the New York State Transmission System or the Connecting Transmission Owner’s Attachment Facilities it deems necessary during an Emergency State in order to (i) preserve public health and safety, (ii) preserve the reliability of the New York State Transmission System or the Connecting Transmission Owner’s Attachment Facilities, (iii) limit or prevent damage, and (iv) expedite restoration of service. NYISO and Connecting Transmission Owner shall use Reasonable Efforts to minimize the effect of such actions or inactions on the Large Generating Facility or the Developer’s Attachment Facilities. NYISO or Connecting Transmission Owner may, on the basis of technical considerations, require the Large Generating Facility to mitigate an Emergency State by taking actions necessary and limited in scope to remedy the Emergency State, including, but not limited to, directing Developer to shut-down, start-up, increase or decrease the real or reactive power output of the Large Generating Facility; implementing a reduction or disconnection pursuant to Article 13.4.2; directing the Developer to assist with blackstart (if available) or restoration efforts; or altering the outage schedules of the Large Generating Facility and the Developer’s Attachment Facilities. Developer shall comply with all of the NYISO and Connecting Transmission Owner’s operating instructions concerning Large Generating Facility real power and reactive power output within the manufacturer’s design limitations of the Large Generating Facility’s equipment that is in service and physically available for operation at the time, in compliance with Applicable Laws and Regulations.

  • SS7 Network Interconnection 9.7.1 SS7 Network Interconnection is the interconnection of Global Connection local signaling transfer point switches or Global Connection local or tandem switching systems with BellSouth signaling transfer point switches. This interconnection provides connectivity that enables the exchange of SS7 messages among BellSouth switching systems and databases, Global Connection local or tandem switching systems, and other third-party switching systems directly connected to the XxxxXxxxx XX0 network.

  • Network Interconnection 26.1 Interconnection between the networks of different SERVICE PROVIDERs shall be as per National Standards of CCS No.7 issued from time to time by Telecom Engineering Centre (TEC) and also subject to technical feasibility and technical integrity of the Networks and shall be within the overall framework of interconnection regulations issued by the TRAI from time to time. However, if situation so arises, INTERCONNECTION with R2MF signaling may be permitted by LICENSOR.

  • System Impact Study An assessment by the Transmission Provider of (i) the adequacy of the Transmission System to accommodate a Completed Application, an Interconnection Request or an Upgrade Request, (ii) whether any additional costs may be incurred in order to provide such transmission service or to accommodate an Interconnection Request, and (iii) with respect to an Interconnection Request, an estimated date that an Interconnection Customer’s Customer Facility can be interconnected with the Transmission System and an estimate of the Interconnection Customer’s cost responsibility for the interconnection; and (iv) with respect to an Upgrade Request, the estimated cost of the requested system upgrades or expansion, or of the cost of the system upgrades or expansion, necessary to provide the requested incremental rights.

  • Construction Sequencing In general, the sequence of the proposed dates of Initial Operation of Interconnection Customers seeking interconnection to the Transmission System will determine the sequence of construction of Network Upgrades.