Main Switches Sample Clauses

Main Switches. Each switch shall have a rated normal current of 630 A. Each switch equipment shall have a rated short-circuit making capacity and short-t time rating equivalent to 1500 MVA at 33 KV. The rated short-circuit making capacity and rated short-time current shall apply when operated to the “ON” and “Earth ON” positions. The operating mechanisms and inter locks shall be in accordance to the ENA 41-12 as appropriate. Testing facilities shall be provided for carrying out test on the feeder connected to the switch. Each switch shall be complete with cable box suitable for accepting cable with (300-500) mm2 cross-sections, Al \ XLPE, 3/single cores 33 KV, and and 3 core 33kv cables having cross section of (3x120-3x300) mm2 AL, XLPE.
AutoNDA by SimpleDocs
Main Switches. Air break switches, disconnectors and MCCB's shall be used as appropriate. They shall be designed and rated in accordance with IEC 60408 and IEC 60947-2 as appropriate for the LV system symmetrical fault rating, and shall be capable of breaking rated load current. Interlocking shall be provided to prevent access to the interior of the unit unless in the "off" position. Padlocking facilities shall be provided to enable the device to be locked in the "off" position and also, where applicable, in the "earth" or "test" positions. The position of contacts shall be externally visible. Alternatively positively linked externally visible mechanical indication for the "on", "off" and, where applicable, "earth" positions may be provided subject to full details being submitted and approved by the Engineer. Fuse switches and switch fuses may be used only with the approval of the Engineer. The maximum size of fuse to be used in a fuse switch or switch fuse shall be indicated on the rating plate.

Related to Main Switches

  • Tandem Switching 4.3.1 The Tandem Switching capability Network Element is defined as: (i) trunk- connect facilities, which include, but are not limited to, the connection between trunk termination at a cross connect panel and switch trunk card; (ii) the basic switch trunk function of connecting trunks to trunks; and (iii) the functions that are centralized in the Tandem Switches (as distinguished from separate end office switches), including but not limited to call recording, the routing of calls to operator services and signaling conversion features.

  • Radios The Contractor or its employees shall not use any of the two-way radios or special telecommunications equipment under any circumstances. No exceptions will be made to this rule. Violation is grounds for immediate termination of this Contract, as well as punitive action.

  • Local Switching BellSouth shall provide non-discriminatory access to local circuit switching capability, and local tandem switching capability, on an unbundled basis, except as set forth below in Section 3.1.3 to Mpower for the provision of a telecommunications service. BellSouth shall provide non-discriminatory access to packet switching capability on an unbundled basis to Mpower for the provision of a telecommunications service only in the limited circumstance described below in Section 3.3.4.6.

  • Switching All of the negotiated rates, terms and conditions set forth in this Section pertain to the provision of local and tandem switching.

  • Ditches (1) Remove bank slough, minor slides, and obstructions.

  • Tandem Switched Transport 7.3.4.2.1 For traffic delivered through a CenturyLink or CLEC tandem Switch (as defined in the Agreement), the Parties agree that, because this State is a new market for CLEC, tandem switched transport functions for Exchange Service (EAS/Local) non-transit traffic shall be compensated based upon the xxxx and keep compensation mechanism. Xxxx and keep will apply to both the tandem switching rate and the tandem transmission rate. Xxxx and keep shall govern compensation for such traffic exchanged by the Parties in this State until the earlier of: (1) the expiration of the Agreement, or (2) further action by the Federal Communications Commission (FCC), or a court of competent jurisdiction, vacates, replaces, modifies, or supersedes the applicable rules adopted in Order on Remand and Report and Order, CC Docket Nos. 96-98, 00-00, XXX 00-000 (xxx. Apr. 27, 2001). 7.3.4.2.2 Intentionally Left Blank.

  • Local Switching Interfaces 4.2.13.1 Newcomm shall order ports and associated interfaces compatible with the services it wishes to provide as listed in Exhibit A. BellSouth shall provide the following local switching interfaces:

  • Manual Disconnect Switch 5.1 U.L.1741 Listed, inverter-based Tier 1 customer-owned renewable generation systems do not require a customer-installed manual disconnect switch.

  • Workstation/Laptop encryption All workstations and laptops that process and/or store DHCS PHI or PI must be encrypted using a FIPS 140-2 certified algorithm which is 128bit or higher, such as Advanced Encryption Standard (AES). The encryption solution must be full disk unless approved by the DHCS Information Security Office.

  • Servers Marco backs up the following servers only: Windows Servers, SQL servers, Exchange server, and Virtual Machines images running VMWare or Hyper V.

Time is Money Join Law Insider Premium to draft better contracts faster.