Need for Data Acquisition Provisions Sample Clauses

Need for Data Acquisition Provisions. In recognition that the coordination of the system operations by the Parties may be facilitated by the sharing of power flow and other real-time information from meters and other equipment at the Interconnection Points, the Parties may agree to cooperate on the installation and operation of data acquisition system (“DAS”) equipment including, but not limited to, remote terminal units (“RTU”), meters, MW/MVAR and Volt transducers, telecommunication devices, lease lines, and any related equipment at points which shall from time to time be mutually agreed upon. Therefore, the Parties establish this Appendix III to govern the general principles of such DAS arrangements. Each of these general principles may be modified within and by a specific agreement for a specific DAS arrangement. Pursuant to a separately negotiated and executed agreement, a Party’s RTU, or equivalent devices, may be shared by the other Party. Therefore, pursuant to such agreement, the RTU shall support multiple dedicated communication ports with mutually agreed upon communication protocols. If a backup telemetry system or data is required by one Party for their own use, the requesting Party shall be responsible for installing and/or maintaining the field devices and associated telecommunication system at their cost. Where there are protocol restrictions because of existing legacy systems, industry standard protocols such as DNP 3.0 shall be offered. If a proprietary communication protocol is to be used solely for one Party, the requesting Party shall be responsible for the cost of adding the customized communication protocol to the RTU. The following real-time data shall be provided to all parties as minimum requirements: three phase bi-directional energy flows (e.g., MWh, MVARh), three phase instantaneous power flows (e.g. MW, MVAR), per phase RMS voltages, per phase RMS currents, and frequency measurement with at least two decimal points resolution shall be provided. In addition to the real-time data, the status of all switching devices associated with the interconnection circuit(s) shall be provided. For the energy flow data, either or both accumulated data or hourly interval data shall be provided based on mutually agreed formats. If accumulated data is used, the owner of the RTU will freeze the accumulated data buffers at the beginning of each clock hour and the other Party shall read the frozen data. This shall be accomplished in a manner that provides both Parties with the same accu...
AutoNDA by SimpleDocs
Need for Data Acquisition Provisions. In recognition that the coordination of the system operations by the Parties may require the sharing of power flow and other real time information from meters and other equipment at the Interconnection Points, the Parties agree to cooperate on the installation and operation of data acquisition system (“DAS”) equipment (including, but not limited to, remote terminal units (“RTUs”), meters, MW/MVAR and Volt transducers, telecommunication devices, and lease lines) at points which shall from time to time be mutually agreed upon. This Appendix II shall govern the general principles of such DAS arrangements. Each of these general principles may be modified within and by a specific agreement for a specific DAS arrangement.

Related to Need for Data Acquisition Provisions

  • Provide Data in Compliance with Applicable Laws LEA shall provide Student Data for the purposes of obtaining the Services in compliance with all applicable federal, state, and local privacy laws, rules, and regulations, all as may be amended from time to time.

  • Provide Data In Compliance With Laws LEA shall provide data for the purposes of the DPA in compliance with the FERPA, PPRA, IDEA, 603 C.M.R. 23.00, 603 CMR 28.00, and Massachusetts General Law, Chapter 71, Sections 34D to 34H, and the other privacy statutes quoted in this DPA. LEA shall ensure that its annual notice under FERPA includes vendors, such as the Provider, as “School Officials.”

  • Supervisory Control and Data Acquisition (SCADA) Capability The wind plant shall provide SCADA capability to transmit data and receive instructions from the ISO and/or the Connecting Transmission Owner for the Transmission District to which the wind generating plant will be interconnected, as applicable, to protect system reliability. The Connecting Transmission Owner for the Transmission District to which the wind generating plant will be interconnected and the wind plant Developer shall determine what SCADA information is essential for the proposed wind plant, taking into account the size of the plant and its characteristics, location, and importance in maintaining generation resource adequacy and transmission system reliability in its area.

  • ADDITIONAL SPECIAL CONTRACT CONDITIONS A. Special Contract Conditions revisions: the corresponding subsections of the Special Contract Conditions referenced below are replaced in their entirety with the following:

Draft better contracts in just 5 minutes Get the weekly Law Insider newsletter packed with expert videos, webinars, ebooks, and more!