Physical Protection. For protection against direct contact with high voltage live parts, the protection degree IPXXB shall be provided. The assessment shall be conducted in accordance with paragraph 4 of Annex 9.
Appears in 7 contracts
Physical Protection. For protection against direct contact with high voltage live parts, the protection degree IPXXB shall be provided. The assessment shall be conducted in accordance with paragraph 4 of Annex 95.
Appears in 2 contracts
Samples: www.marklines.com, unece.org
Physical Protection. For protection against direct contact with high voltage live parts, the protection degree IPXXB shall be provided. The assessment shall be conducted in accordance with paragraph 4 of Annex 911.
Appears in 2 contracts
Physical Protection. For protection against direct contact with high voltage live parts, the protection degree IPXXB shall be provided. The assessment shall be conducted in accordance with paragraph 4 of Annex 9.11. In addition, for protection against electrical shock which could arise from indirect contact, the resistance between all exposed conductive parts of electrical protection barriers/enclosures and the electrical chassis shall be lower than 0.1 Ω and the resistance between any two simultaneously reachable exposed conductive parts of electrical protection barriers/enclosures that are less than 2.5 m from each other shall be less than