Loop Provisioning Involving Integrated Digital Loop Carriers 2.6.1 Where Xxxx has requested an Unbundled Loop and BellSouth uses IDLC systems to provide the local service to the End User and BellSouth has a suitable alternate facility available, BellSouth will make such alternative facilities available to Xxxx. If a suitable alternative facility is not available, then to the extent it is technically feasible, BellSouth will implement one of the following alternative arrangements for Xxxx (e.g. hairpinning): 1. Roll the circuit(s) from the IDLC to any spare copper that exists to the customer premises. 2. Roll the circuit(s) from the IDLC to an existing DLC that is not integrated. 3. If capacity exists, provide "side-door" porting through the switch. 4. If capacity exists, provide "Digital Access Cross Connect System (DACS)- door" porting (if the IDLC routes through a DACS prior to integration into the switch). 2.6.2 Arrangements 3 and 4 above require the use of a designed circuit. Therefore, non- designed Loops such as the SL1 voice grade and UCL-ND may not be ordered in these cases. 2.6.3 If no alternate facility is available, and upon request from Xxxx, and if agreed to by both Parties, BellSouth may utilize its Special Construction (SC) process to determine the additional costs required to provision facilities. Xxxx will then have the option of paying the one-time SC rates to place the Loop.
Unbundled Sub-Loop Distribution Voice Grade (USLD-VG) is a copper sub- loop facility from the cross-box in the field up to and including the point of demarcation at the End User’s premises and may have load coils.
Shared Transport The Shared Transport Network Element (“Shared Transport”) provides the collective interoffice transmission facilities shared by various Carriers (including Qwest) between end-office switches and between end-office switches and local tandem switches within the Local Calling Area. Shared Transport uses the existing routing tables resident in Qwest switches to carry the End User Customer’s originating and terminating local/extended area service interoffice Local traffic on the Qwest interoffice message trunk network. CLEC traffic will be carried on the same transmission facilities between end- office switches, between end-office switches and tandem switches and between tandem switches on the same network facilities that Qwest uses for its own traffic. Shared Transport does not include use of tandem switches or transport between tandem switches and end-office switches for Local Calls that originate from end users served by non- Qwest Telecommunications Carriers (“Carrier(s)”) which terminate to QLSP End Users.
Unbundled Copper Sub-Loop (UCSL) is a copper facility of any length provided from the cross-box in the field up to and including the end-user’s point of demarcation. If available, this facility will not have any intervening equipment such as load coils between the end-user and the cross-box.
Distribution Services 3.1. Distributor will have the right, as agent for the Fund, to enter into dealer agreements with responsible investment dealers, and to sell Shares to such investment dealers against orders therefor at the public offering price (as defined below) stated in the Fund’s effective Registration Statement on Form N-2 under the 1940 Act and the Securities Act of 1933, as amended (the “Securities Act”), including the then-current prospectus and statement of additional information (the “Registration Statement”). Upon receipt of an order to purchase Shares from a dealer with whom Distributor has a dealer agreement, Distributor will promptly cause such order to be filled by the Fund. 3.2. Distributor will also have the right, as agent for the Fund, to sell such Shares to the public against orders therefor at the public offering price (as defined below) and in accordance with the Registration Statement. 3.3. Distributor will also have the right to take, as agent for the Fund, all actions which, in Distributor’s reasonable judgment, are necessary to carry into effect the distribution of the Shares. 3.4. The “public offering price” for the Shares of the Fund shall be the net asset value (“NAV”) of the Shares then in effect, plus any applicable sales charge determined in the manner set forth in the Registration Statement or as permitted by the 1940 Act and the rules and regulations promulgated by the SEC or other applicable regulatory agency or self-regulatory organization under the oversight of the SEC. In no event shall any applicable sales charge exceed the maximum sales charge permitted by the Rules of FINRA. 3.5. The NAV of the Shares of the Fund shall be determined in the manner provided in the Registration Statement, and when determined shall be applicable to transactions as provided for in the Registration Statement. The NAV of the Shares shall be calculated by the Fund or by another entity on behalf of the Fund. Distributor shall have no duty to inquire into or liability for the accuracy of the NAV per Share as calculated. 3.6. On every sale, the Fund shall receive the applicable NAV of the Shares promptly, but in no event later than the third business day following the date on which Distributor shall have received an order for the purchase of the Shares. 3.7. Upon receipt of purchase instructions, Distributor will transmit such instructions to the Fund or its transfer agent for the issuance and registration of the Shares purchased. 3.8. Distributor, as agent of and for the account of the Fund, may repurchase the Shares at such prices and upon such terms and conditions as shall be specified in the Registration Statement. 3.9. Distributor shall maintain membership with the National Securities Clearing Corporation (“NSCC”) and any other similar successor organization to sponsor a participant number for the Fund so as to enable the Shares to be traded through FundSERV. The Distributor shall not be responsible for any operational matters associated with FundSERV or networking transactions. 3.10. Distributor will review all proposed advertising materials and sales literature for compliance with Applicable Law and shall file such materials with appropriate regulators as required by current laws and regulations. Distributor agrees to furnish the Fund with any comments provided by regulators with respect to such materials. 3.11. Distributor shall prepare or cause to be prepared reports for the Board of Trustees (the “Board”) of the Fund regarding its activities under this Agreement as reasonably requested by the Board.
COSTS DISTRIBUTED THROUGH COUNTYWIDE COST ALLOCATIONS The indirect overhead and support service costs listed in the Summary Schedule (attached) are formally approved as actual costs for fiscal year 2022-23, and as estimated costs for fiscal year 2024-25 on a “fixed with carry-forward” basis. These costs may be included as part of the county departments’ costs indicated effective July 1, 2024, for further allocation to federal grants and contracts performed by the respective county departments.
Meter Testing Company shall provide at least twenty-four (24) hours' notice to Seller prior to any test it may perform on the revenue meters or metering equipment. Seller shall have the right to have a representative present during each such test. Seller may request, and Company shall perform, if requested, tests in addition to the every fifth-year test and Seller shall pay the cost of such tests. Company may, in its sole discretion, perform tests in addition to the fifth year test and Company shall pay the cost of such tests. If any of the revenue meters or metering equipment is found to be inaccurate at any time, as determined by testing in accordance with this Section 10.2 (Meter Testing), Company shall promptly cause such equipment to be made accurate, and the period of inaccuracy, as well as an estimate for correct meter readings, shall be determined in accordance with Section 10.3 (Corrections).
Voice Grade Unbundled Copper Sub-Loop Unbundled Sub-Loop Distribution – Intrabuilding Network Cable (aka riser cable)
Distribution Upgrades The Connecting Transmission Owner shall design, procure, construct, install, and own the Distribution Upgrades described in Attachment 6 of this Agreement. If the Connecting Transmission Owner and the Interconnection Customer agree, the Interconnection Customer may construct Distribution Upgrades. The actual cost of the Distribution Upgrades, including overheads, shall be directly assigned to the Interconnection Customer. The Interconnection Customer shall be responsible for its share of all reasonable expenses, including overheads, associated with owning, operating, maintaining, repairing, and replacing the Distribution Upgrades, as set forth in Attachment 6 to this Agreement.
Redistribution If any amount owing by an Obligor under any Finance Document to a Finance Party (the recovering Finance Party) is discharged by payment, set-off or any other manner other than through the Facility Agent in accordance with Clause 9 (Payments) (a recovery), then: (a) the recovering Finance Party shall, within three Business Days, notify details of the recovery to the Facility Agent; (b) the Facility Agent shall determine whether the recovery is in excess of the amount which the recovering Finance Party would have received had the recovery been received by the Facility Agent and distributed in accordance with Clause 9 (Payments); (c) subject to Clause 29.3 (Exceptions), the recovering Finance Party shall, within three Business Days of demand by the Facility Agent, pay to the Facility Agent an amount (the redistribution) equal to the excess; (d) the Facility Agent shall treat the redistribution as if it were a payment by the Obligor concerned under Clause 9 (Payments) and shall pay the redistribution to the Finance Parties (other than the recovering Finance Party) in accordance with Clause 9.7 (Partial payments); and (e) after payment of the full redistribution, the recovering Finance Party will be subrogated to the portion of the claims paid under paragraph (d) above, and that Obligor will owe the recovering Finance Party a debt which is equal to the redistribution, immediately payable and of the type originally discharged.