Test Dispatch Notices. (a) Availability Tests (i) CAISO may from time to time test the Availability of a Unit by requiring the Unit to Deliver Energy pursuant to a Test Dispatch Notice provided to Owner’s Scheduling Coordinator using the procedures described in Section 4.2 and 4.3. CAISO, without cause, may request one Availability Test each Contract Year. CAISO may request additional Availability Tests if the Unit fails to comply fully with a Dispatch Notice. CAISO shall not request an Availability Test for a hydroelectric Unit during periods of constrained water availability. Lack of available water shall not be deemed to result in a failed test and reduction of the Unit Availability Limit for a hydroelectric Unit. (ii) Owner may request an Availability Test at any time. CAISO shall issue a Test Dispatch Notice within three days after receipt of Owner’s request, but for good cause, CAISO may reschedule the test to a date acceptable to Owner. Owner’s request shall state the amount of Energy to be produced. The effect of operations pursuant to such a request is set out in Section 5.3. (iii) The Test Dispatch Notice shall be marked “Availability Test Dispatch Notice.” The Test Dispatch Notice shall specify a Requested Operation Period of four hours of continuous operations at the requested output plus any applicable Start- up Lead Time, time to satisfy Ramping Constraints and time for Shutdown (or for hydroelectric Units the time sufficient water is available, if that is less). (iv) Subject to the other conditions or restrictions expressed in this Agreement, Owner shall provide service from the Unit and Deliver the Requested MWh in accordance with the Availability Test Dispatch Notice; provided, however, that Owner, in response to such Test Dispatch Notice, may deliver all or part of the Requested MWh in a Market Transaction by complying with the procedures set forth in Section 5.2. (v) An Availability Test shall be treated as having been successfully completed if the average MW Delivered at the Delivery Point during the Availability Test was not less than 99% of the Requested MW for the Requested Operation Period. The average MW Delivered during the Availability Test shall be computed by dividing (i) the total MWh produced during the four-hour period immediately following completion of the ramp up, multiplied by the appropriate ambient temperature correction factors for the Unit as set out in Section 3 of Schedule A, by (ii) four hours. (vi) If a Unit fails an Availability Test,...

Related to Test Dispatch Notices

  • Review Notices On receipt of a Review Notice from the Indenture Trustee according to Section 7.2 of the Indenture, the Asset Representations Reviewer will start a Review. The Asset Representations Reviewer will not be obligated to start a Review until a Review Notice is received.

  • Transmission Delivery Service Implications Under ER Interconnection Service, Interconnection Customer will be eligible to inject power from the Generating Facility into and deliver power across the Transmission System on an “as available” basis up to the amount of MW identified in the applicable stability and steady state studies to the extent the upgrades initially required to qualify for ER Interconnection Service have been constructed. After that date FERC makes effective MISO’s Energy Market Tariff filed in Docket No. ER04-691-000, Interconnection Customer may place a bid to sell into the market up to the maximum identified Generating Facility output, subject to any conditions specified in the Interconnection Service approval, and the Generating Facility will be dispatched to the extent the Interconnection Customer’s bid clears. In all other instances, no transmission or other delivery service from the Generating Facility is assured, but Interconnection Customer may obtain Point-To-Point Transmission Service, Network Integration Transmission Service or be used for secondary network transmission service, pursuant to the Tariff, up to the maximum output identified in the stability and steady state studies. In those instances, in order for Interconnection Customer to obtain the right to deliver or inject energy beyond the Point of Interconnection or to improve its ability to do so, transmission delivery service must be obtained pursuant to the provisions of the Tariff. The Interconnection Customer’s ability to inject its Generating Facility output beyond the Point of Interconnection, therefore, will depend on the existing capacity of the Transmission or Distribution System as applicable, at such time as a Transmission Service request is made that would accommodate such delivery. The provision of Firm Point-To-Point Transmission Service or Network Integration Transmission Service may require the construction of additional Network or Distribution Upgrades.

  • Notice of Events As soon as Guarantor obtains knowledge thereof, Guarantor shall give Guarantied Party written notice of any condition or event which has resulted in (a) a material adverse change in the financial condition of Guarantor or Company or (b) any Event of Default or Potential Event of Default.

  • Third Party Notices Portions of the Apple Software or Services may utilize or include third party software and other copyrighted material. Acknowledgements, licensing terms and disclaimers for such material are contained in the electronic documentation for the Apple Software and Services, and Your use of such material is governed by their respective terms.

  • Information Submission by Connecting Transmission Owner The initial information submission by Connecting Transmission Owner shall occur no later than one hundred eighty (180) Calendar Days prior to Trial Operation and shall include New York State Transmission System information necessary to allow the Developer to select equipment and meet any system protection and stability requirements, unless otherwise mutually agreed to by the Developer and Connecting Transmission Owner. On a monthly basis Connecting Transmission Owner shall provide Developer and NYISO a status report on the construction and installation of Connecting Transmission Owner’s Attachment Facilities and System Upgrade Facilities and System Deliverability Upgrades, including, but not limited to, the following information: (1) progress to date; (2) a description of the activities since the last report; (3) a description of the action items for the next period; and (4) the delivery status of equipment ordered.

  • Notice of Completion The Interconnection Customer shall notify the Transmission Provider and the Interconnected Transmission Owner in writing when it has completed construction of (i) the Customer Facility;

  • Sending Notices Any notice required or permitted to be given under this Security Agreement shall be sent in accordance with Section 9.01 of the Credit Agreement.

  • Notification to Unsuccessful Job Applicants The parties agree that any unsuccessful candidate for an ONA job posting will be notified, in writing, within one (1) week of the decision being made and prior to the posting of the name of the successful candidate. The parties further agree that the above notification will be copied to the ONA Bargaining Unit President.

  • Notices of Material Events The Borrower will furnish to the Administrative Agent and each Lender prompt written notice of the following: (a) the occurrence of any Default; (b) the filing or commencement of, or the threat in writing of, any action, suit, proceeding, investigation or arbitration by or before any arbitrator or Governmental Authority against or affecting the Borrower or any Affiliate thereof not previously disclosed in writing to the Lenders or any material adverse development in any action, suit, proceeding, investigation or arbitration (whether or not previously disclosed to the Lenders) that, in either case, if adversely determined, could reasonably be expected to result in a Material Adverse Effect; and (c) any other development that results in, or could reasonably be expected to result in, a Material Adverse Effect. Each notice delivered under this Section 8.02 shall be accompanied by a statement of a Responsible Officer setting forth the details of the event or development requiring such notice and any action taken or proposed to be taken with respect thereto.

  • Updated Information Submission by Interconnection Customer The updated information submission by the Interconnection Customer, including manufacturer information, shall occur no later than one hundred eighty (180) Calendar Days prior to the Trial Operation. The Interconnection Customer shall submit a completed copy of the Electric Generating Unit data requirements contained in Appendix 1 to the LGIP. It shall also include any additional information provided to the Participating TO and the CAISO for the Interconnection Studies. Information in this submission shall be the most current Electric Generating Unit design or expected performance data. Information submitted for stability models shall be compatible with the Participating TO and CAISO standard models. If there is no compatible model, the Interconnection Customer will work with a consultant mutually agreed to by the Parties to develop and supply a standard model and associated information.