Unbundled Subloop Distribution. 2.8.2.1 The USLD facility isa dedicated transmissionfacility that AT&Tprovides from a customer’s point of demarcation to a AT&T cross-connect device. The AT&T cross-connect device may be located within a remote terminal (RT) or a stand-alone cross-box in the field or in the equipment room of a building. The USLD media is a copper twisted pair that can be provisioned as a 2-wire or 4-wire facility. AT&Twill make available the followinsgubloop distribuiton offerings wheer facilities exist: USLD – Voice Grade (USLD-VG) Unbundled Copper Subloop (UCSL) USLD – Intrabuilding Network Cable (USLD-INC (aka riser cable))
2.8.2.2 USLD-VG is a copper subloop facilitfyrom the cross-box in the fiedlup to and including the point of demarcation at the customer’s premises and may have load coils.
2.8.2.3 UCSL is a copper facilityeighteen thousand (18,000) feet or lesins length provided from the cross- box in the field up to and includinghte customer’s point of demarcationI.f available, this facility will not have any intervening equipment such as load coils between the customer and the cross-box.
2.8.2.3.1 If AIN/Birch requests a UCSL and it is not available, AIN/Birchmay request the copper Subloop facility bemodiefid pursuant to the ULM process to remvoe load coils and/orexcessive bridged taps. If load coils and/or excesvsei bridged taps are removedh, te facility will beclassified as a UCSL.
2.8.2.4 USLD-INC is the distribution facility ownedor controlled by AT&T inside a building or between buildings on the same property that is not separated by a public street or road. USLD-INC includes the facility fromthe cross-connect device in the buinldgi equipment room up to and including the point of demarcation at the customer’s premises.
2.8.2.4.1 Upon request for USLD-INC from AIN/Birch, AT&wTill install a cross-connetcpanel in the building equipment room for the purpose of accessing USLD-INC pairs from a building equipment room. The cross-connect paneliwll functoi n as a single point of interconnection (SPOI) for USLD-INC and will be accessible by multiplecarriers as space permits. A&TTwill place cross-connect blocks in twenty five (25) pair increments for AIN/Birchu’sse on this cross-connecptanel. AIN/Birch will be responsible for connecting itscfailities to the twenty five2(5) pair cross-connect block(s).
2.8.2.5 For access to Voice Grade USLD and UCSL, AIN/Birch shall install a cable to the AT&T cross-box pursuant to the terms and conditions for physical collocation for rem...
Unbundled Subloop Distribution. 2.15.2.1 The Unbundled Subloop Distribution facility is a dedicated transmission facility that AT&T provides from a customer‟s point of demarcation to a AT&T cross- connect device. The AT&T cross-connect device may be located within a remote terminal (RT) or a stand-alone cross-box in the field or in the equipment room of a building. The unbundled sub-loop distribution media is a copper twisted pair that can be provisioned as a 2-Wire or 4-Wire facility. AT&T will make available the following sub-loop distribution offerings where facilities exist:
Unbundled Subloop Distribution. Intrabuilding Network Cable (USLD-INC) is the distribution facility owned or controlled by AT&T inside a building or between buildings on the same property that is not separated by a public street or road. USLD-INC includes the facility from the cross-connect device in the building equipment room up to and including the point of demarcation at the customer‟s premises.
2.15.2.1.3.1 Upon request for USLD-INC from NuVox, AT&T will install a cross-connect panel in the building equipment room for the purpose of accessing USLD-INC pairs from a building equipment room. The cross-connect panel will function as a single point of interconnection (SPOI) for USLD-INC and will be accessible by multiple carriers as space permits. AT&T will place cross-connect blocks in 25- pair increments for NuVox‟s use on this cross-connect panel. NuVox will be responsible for connecting its facilities to the 25-pair cross-connect block(s). Page 91 of 327
Unbundled Subloop Distribution. 2.8.2.1 The USLD facility is a dedicated transmission facility that AT&T provides from a customer’s point of demarcation to an AT&T cross-connect device. The AT&T cross-connect device may be located within a remote terminal (RT) or a stand- alone cross-box in the field or in the equipment room of a building. The USLD media is a copper twisted pair that can be provisioned as a 2-wire or 4-wire facility. AT&T will make available the following subloop distribution offerings where facilities exist: USLD – Voice Grade (USLD-VG) Unbundled Copper Subloop (UCSL) USLD – Intrabuilding Network Cable (USLD-INC (aka riser cable)) Page 85 of 419
Unbundled Subloop Distribution. Intrabuilding Network Cable (USLD-INC) is the distribution facility owned or controlled by AT&T inside a building or between buildings on the same property that is not separated by a public street or road. USLD-INC includes the facility from the cross-connect device in the building equipment room up to and including the point of demarcation at the end user customer’s premises. Page 91 of 321 Attachment 2 – Network Elements and Other Services/BELLSOUTH TELECOMMUNICATIONS, INC. AT&T SOUTH CAROLINA/NUVOX 2.15.1.3.1 Upon request for USLD-INC from NuVox, AT&T will install a cross-connect panel in the building equipment room for the purpose of accessing USLD-INC pairs from a building equipment room. The cross-connect panel will function as a single point of interconnection (SPOI) for USLD-INC and will be accessible by multiple carriers as space permits. AT&T will place cross-connect blocks in 25- pair increments for NuVox’s use on this cross-connect panel. NuVox will be responsible for connecting its facilities to the 25-pair cross-connect block(s).
Unbundled Subloop Distribution. Voice Grade (“USLD-VG”) is a subloop facility from the cross-box in the field up to and including the point of demarcation, at the end user’s premises and may have load coils.
Unbundled Subloop Distribution. 2.8.2.1 The USLD facility is a dedicated transmission facility that BellSouth provides from a customer’s point of demarcation to a BellSouth cross-connect device. The BellSouth cross-connect device may be located within a remote terminal (RT) or a stand-alone cross-box in the field or in the equipment room of a building. The USLD media is a copper twisted pair that can be provisioned as a 2-wire or 4-wire facility. BellSouth will make available the following subloop distribution offerings where facilities exist:
2.8.2.2 USLD-VG is a copper subloop facility from the cross-box in the field up to and including the point of demarcation at the customer’s premises and may have load coils.
2.8.2.3 UCSL is a copper facility eighteen thousand (18,000) feet or less in length provided from the cross-box in the field up to and including the customer’s point of demarcation. If available, this facility will not have any intervening equipment such as load coils between the customer and the cross-box.
2.8.2.3.1 If <<customer_short_name>> requests a UCSL and it is not available,
2.8.2.4 USLD-INC is the distribution facility owned or controlled by BellSouth inside a building or between buildings on the same property that is not separated by a public street or road. USLD-INC includes the facility from the cross-connect device in the building equipment room up to and including the point of demarcation at the customer’s premises.
2.8.2.4.1 Upon request for USLD-INC from <<customer_short_name>>, BellSouth will install a cross-connect panel in the building equipment room for the purpose of accessing USLD-INC pairs from a building equipment room. The cross-connect panel will function as a single point of interconnection (SPOI) for USLD-INC and Version: 4Q06 Standard ICA 11/30/06 <<customer_short_name>>’s use on this cross-connect panel. <<customer_short_name>> will be responsible for connecting its facilities to the twenty five (25) pair cross-connect block(s).
2.8.2.5 For access to Voice Grade USLD and UCSL, <<customer_short_name>> shall install a cable to the BellSouth cross-box pursuant to the terms and conditions for physical collocation for remote sites set forth in Attachment 4. This cable would be connected by a BellSouth technician within the BellSouth cross-box during the set-up process. <<customer_short_name>>’s cable pairs can then be connected to BellSouth’s USL within the BellSouth cross-box by the BellSouth technician.
2.8.2.6 Through the SI process, BellSouth will ...
Unbundled Subloop Distribution. 2.15.2.1 The Unbundled Subloop Distribution facility is a dedicated transmission facility that AT&T provides from a customer’s point of demarcation to an AT&T cross- connect device. The AT&T cross-connect device may be located within a remote terminal (RT) or a stand-alone cross-box in the field or in the equipment room of a building. The unbundled subloop distribution media is a copper twisted pair that can be provisioned as a 2-Wire or 4-Wire facility. AT&T will make available the following subloop distribution offerings where facilities exist: Unbundled Subloop Distribution – Voice Grade Unbundled Copper Subloop Page 9905 of 331382 AT&T Alabama, AT&T Louisiana/NuVox Unbundled Subloop Distribution – Intrabuilding Network Cable (aka riser cable)
Unbundled Subloop Distribution. Intrabuilding Network Cable (USLD-INC) is the distribution facility owned or controlled by BellSouth inside a building or between buildings on the same property that is not separated by a public street or road. USLD-INC includes the facility from the cross-connect device in the building equipment room up to and including the point of demarcation at the customer’s premises.
2.8.2.4.1 Upon request for USLD-INC from MCI, BellSouth will install a cross-connect panel in the building equipment room for the purpose of accessing USLD-INC pairs from a building equipment room. The cross-connect panel will function as a single point of interconnection (SPOI) for USLD-INC and will be accessible by multiple carriers as space permits. BellSouth will place cross-connect blocks in 25-pair increments for MCI’s use on this cross-connect panel. MCI will be responsible for connecting its facilities to the 25-pair cross-connect block(s).
Unbundled Subloop Distribution