Units and Accuracy Sample Clauses

Units and Accuracy. [For PV] The Table below shows minimum required solar irradiance measurements for various types of solar generation technology. [DRAFTING NOTE: VALUES NEED TO BE INSERTED INTO TABLE.] This value may not be derived. Solar Technology Direct Normal Irradiance Global Irradiance (GHI) Plane of Array Irradiance (POA) Flat Plate (fixed horizontal, fixed angle, tracking, roof mounted) X X Units and accuracy of measured parameters to be provided to Company in real time shall be as shown in the Table below. These represent the minimum required accuracies. Table of Units and Accuracy of Meteorological and Production Data (PV) Parameter Data Source Unit Range Accuracy Global Horizontal Irradiance at MMS Pyranometer or equivalent W/m2 0 to 1500 W/m2 Secondary standard per ISO 9060 or <= 3% from 100 W/m2 to 1500 W/m2 if using a PV Reference Cell Plane of Array Irradiance on same axis as array Pyranometer or equivalent W/m2 0 to 1500 W/m2 Secondary standard per ISO 9060 or <= 3% from 100 W/m2 to 1500 W/m2 if using a PV Reference Cell Back of Panel temperature at array height Temperature probe ºC -20 to +50 ºC +/-1 ºC Power production of Facility Measured at POI MW Up to Capacity +-0.1 MW Inverters Available* Seller’s system digital Up to the number installed inverters Ratio of inverters online/number of inverters % 0 to 100% Power Possible* Seller's Model MW 0 to Allowed Capacity +/-0.1 MW Table of Units and Accuracy of Meteorological and Production Data (Wind) Parameter Data Source Unit Range Accuracy Wind speed at MMT (hub height) Cup or sonic anemometer Mph 0 to 134 mph +/-1 mph Wind direction at MMT (hub height) Vane, sonic device or equivalent Degrees (from True North) 360° +/-5° Ambient air temperature at MMT (hub height) Temperature probe ºC -20 to +50 ºC +/-1 ºC Ambient air pressure at MMT (hub height) Piezoresistive transducer, barometer or equivalent Mbar 150 to 1150 mbar +/-60 mbar (0 to +50ºC) Power production of Facility Measured at POI MW +/- 0.1 mw Power Possible Seller’s Model MW 0 to 120% of Allowed Capacity +/0.1 MW Status of Generating Equipment: For each inverter, or wind turbine, Seller shall provide to Company, via SCADA communication and protocol acceptable to Company at a continuous scan updated not less frequently than every 2 seconds, a signal as to whether such inverter is available or unavailable, and on or offline. Data Collection. [NOTE COMPANY TO UPDATE REQUIREMENTS; WILL BE SPECIFIC TO FACILITY EQUIPMENT AND RESOURCE TYPE] High Resolution ...
AutoNDA by SimpleDocs
Units and Accuracy. A. Units and accuracy of measured parameters to be provided to Company in real time shall be as shown in the Table below. These represent the minimum required accuracies. Table of Units and Accuracy of Meteorological and Production Data (Wind) Parameter Data Source Unit Range Accuracy Wind speed at nacelle of each WTG Cup or sonic anemometer mph 0 to 134 mph +/-1 mph Wind direction at nacelle of each WTG Vane, sonic device or equivalent Degrees (from True North) 360º +/-5º Wind speed at MMT Cup or sonic anemometer mph 0 to 134 mph +/-1 mph Wind direction at MMT Vane, sonic device or equivalent Degrees (from True North) 360° +/-5° Ambient air temperature at MMT (hub height) Temperature probe ºC -20 to +50 ºC +/-1 ºC Ambient air pressure at MMT (hub height) Piezoresistive transducer, barometer or equivalent mbar 150 to 1150 mbar +/-60 mbar (0 to +50ºC) Power production for each WTG Measured at WTG MW Up to WTGS name plate +/-0.1 MW Set point for each WTG Reported by Seller MW 0 to WTGS name plate Not applicable Power production of Facility Measured at Facility's analog transducer on Seller's side of POI MW Up to Allowed Capacity The lesser of the tolerances of the telemetry equipment or 2% of measurement Facility power production ratio Ratio of Facility's power production (MW)/Allowed Capacity (MW) % 0 to 100% +/-0.1% Power Possible Seller’s Model MW 0 to Allowed Capacity +/-4%
Units and Accuracy. The Table below shows minimum required solar irradiance measurements for various types of solar generation technology. [DRAFTING NOTE: VALUES NEED TO BE INSERTED INTO TABLE.] This value may not be derived. Solar Technology Direct Normal Irradiance Global Irradiance (GHI) Plane of Array Irradiance (POA) Flat Plate (fixed horizontal, fixed angle, tracking, roof mounted) X X Units and accuracy of measured parameters to be provided to Company in real time shall be as shown in the Table below. These represent the minimum required accuracies. Table of Units and Accuracy of Meteorological and Production Data (PV) Parameter Data Source Unit Range Accuracy Global Horizontal Irradiance at MMS Pyranometer or equivalent W/m2 0 to 1500 W/m2 Secondary standard per ISO 9060 or <= 3% from 100 W/m2 to 1500 W/m2 if using a PV Reference Cell Plane of Array Irradiance on same axis as array Pyranometer or equivalent W/m2 0 to 1500 W/m2 Secondary standard per ISO 9060 or <= 3% from 100 W/m2 to 1500 W/m2 if using a PV Reference Cell Back of Panel temperature at array height Temperature probe ºC -20 to +50 ºC +/-1 ºC Power production of Facility Measured at POI MW Up to Capacity +/-0.1 MW Inverters available Seller's system digital Up to the number of installed inverters Ratio of inverters online/number of inverters % 0 to 100%
Units and Accuracy. A. [For PV] The Table below shows minimum required solar irradiance measurements for various types of solar generation technology. [DRAFTING NOTE: VALUES NEED TO BE INSERTED INTO TABLE.] This value may not be derived. Solar Technology Direct Normal Irradiance Global Irradiance (GHI) Plane of Array Irradiance (POA) Flat Plate (fixed horizontal, fixed angle, tracking, roof X X mounted)

Related to Units and Accuracy

  • Information Accuracy I (a) certify that the information and representations contained in this Agreement and any other document or information that has been or will be furnished to You in connection with My account(s) is complete, true and correct, and acknowledge that knowingly giving false information for the purpose of inducing You to extend credit is a federal crime, (b) authorize You to contact any individual or firm noted herein or on the documents referred to in subsection (a) of this Section and any other normal sources of debit or credit information, (c) authorize anyone so contacted to furnish such information to You as You may request, and (d) agree that this Agreement and any other document or information I furnish in connection with My account is Your property, as the case may be. I shall promptly advise You of any changes to the information in such agreements, documents, or information. You may retain this Agreement and all other such documents or information and their respective records at Your sole discretion, whether or not credit is extended.

  • Certification of Accuracy The following parties have reviewed the information above and certify, to the best of their knowledge, that the information they have provided is true and accurate. Landlord's Signature Date: Print Name: Tenant’s Signature Date: Print Name: Tenant’s Signature Date: Print Name: Agent’s Signature Date:

  • Representations and Warranties The Borrower represents and warrants to the Lenders that:

  • Complete and Accurate Information Contractor represents and warrants that all statements and information provided to HHS are current, complete, and accurate. This includes all statements and information in this Contract and any related Solicitation Response.

  • Technical Accuracy Owner shall not be responsible for discovering deficiencies in the technical accuracy of Engineer’s services. Engineer shall correct deficiencies in technical accuracy without additional compensation, unless such corrective action is directly attributable to deficiencies in Owner-furnished information.

  • Data Accuracy The Custodian has no responsibility for, or duty to review, verify or otherwise perform any investigation as to the completeness, accuracy or sufficiency of, any data or information provided by or on behalf of the Client, any persons authorized by the Client, any Third Party Agent, any Market Participant or any Authorized Data Sources, except to the extent the Custodian has agreed in writing to perform reconciliations, variance or tolerance checks or other specific forms of data review under this Agreement.

  • Provide Accurate Information You represent and agree that all information you provide to us in connection with the Services is accurate, current, and complete. You agree not to misrepresent your identity or account information. You agree to keep account information secure, up to date and accurate. You represent that you are a legal owner, or an authorized user, of the accounts at third party sites which you include or access through the Services, and that you have the authority to (i) designate us and our service providers as your agent, (ii) use the Services, and (iii) give us and our service providers the passwords, usernames, and all other information you provide.

  • Representations and Warranties of the Borrower The Borrower represents and warrants as follows:

  • Representations and Warranties of Grantee The Grantee represents and warrants to the Company that:

  • Representations and Warranties of Seller Seller represents and warrants to Buyer as follows:

Draft better contracts in just 5 minutes Get the weekly Law Insider newsletter packed with expert videos, webinars, ebooks, and more!