Battery Limits definition

Battery Limits means the batteries of continuous area, within which the Plant is to be erected.
Battery Limits means only the process sections grain cooking, enzymatic hydrolysis and mash cooling (Area 1300), fermentation and fermentation air supply and carbon dioxide scrubber (Area 1400), distillation (Area 1500) , dehydration (Area 1550) and decanter centrifuges (Area 1700). The Battery limits for grain cooking and enzyme hydrolysis (Area 1300) are defined as starting with the equipment in which “fresh substrate charge” is received. Transfer equipment and piping to and from the Battery Limits are not included. Measuring devices for “fresh substrate charge” will be included in the Battery Limits. The Battery Limits for the decanter centrifuge (Area 1700) are defined as ending with the “cake discharge conveyor.” The evaporation section (Area 1600 & Area 1650) will be integrated with the distillation (Area 1500) and the DDGS drier (Area 1800) to recover waste heat and a system specification will be supplied. Detail design by others. Utilities, as are required for the operation of the Licensed Process, are outside the Battery Limits.

Examples of Battery Limits in a sentence

  • The recirculation loop is connected to the base of the flash chamber which is fitted with a vortex breaker to prevent cavitation of the axial-flow pump.Low pressure steam is received from the Battery Limits and the evaporative capacity of the unit is defined by the flow controller on the steam feed.

  • Battery Limits as per “Basic scope” of work The Operation & Maintenance of any equipment beyond the following Battery Limits shall be AFDG responsibility; in general, the boundary limit as per Purchase order is as follows:- Flue Gas: Exhaust flue gas up to XYZ suppl ied silencer outlet excluding diverter value.- Fuel: Supply of Natural Gas at the inlet of Gas Filtration skid.- Lube oil: Drainage of lubricating oil and filling to the empty barrel by M/ s XYZ.

  • Secretaries shall receive either a one-half (.5) hour or a one hour lunch break approximately midway through the shift, as arranged by mutual agreement between the employee and the Sheriff.

  • EDNC shall be responsible for operating and maintaining and shall own or lease from the Owner Trustee (on terms that have been approved by Bayer) all of the improvements inside the Battery Limits of the EDNC Baytown Plant.

  • Figure 2: General Arrangement An indicative schematic of the Project battery limits is provided in Appendix E – Indicative Battery Limits and Scope.


More Definitions of Battery Limits

Battery Limits as used herein shall mean the extent and limits of the process for which Vogelbusch U.S.A., Inc. assumes design liability. Those Battery Limits are described in Schedule B of the License Agreement.
Battery Limits means the lines and points set forth in Schedule 3.
Battery Limits. The boundary lines of the Leased Premises.
Battery Limits as used herein shall mean the extent and limits of the process for which Vogelbusch U.S.A., Inc. assumes design liability. Those Battery Limits are described in Schedule B of the License Agreement. 9. The term “safe operating condition” as used herein shall mean adherence to OSHA, State and local codes and regulations and to sound engineering practice. MAY 1, 2006 PROCESS GUARANTEE SCHEDULE B PRODUCT GUARANTEE The following Product Guarantees are subject to the conditions as specified in Schedule C. Fresh Substrate Charge and Products Not more than 1.96 pounds of starch content in fresh substrate charge average, per pound anhydrous alcohol produced. Daily Capacity Not less than an average of 949,520 pounds (143,000 gallons at 60°F) of anhydrous alcohol per day on the basis of an average of seven consecutive days of Process Guarantee Test Run. Energy Consumption For LICENSOR’S process areas 1300, 1400, 1500, 1550 and 1900: Not more than [ * ] lbs. of steam per pound of anhydrous alcohol produced. (Steam shall be saturated and at a pressure of not less than [ * ] psig at the battery limits.) MAY 1, 2006
Battery Limits means the overall limits of working area within which the Contractor(s) shall perform the Work, as defined under Annex 1-2 (Battery Limits).
Battery Limits means the lines and points set forth in Schedule 2.
Battery Limits means the boundary of the Newcastle Energy Premises as defined in the Lease Agreement;