Change of Design Sample Clauses

Change of Design. A design change is any change in the selection of structural materials or dimensional change not attributable to normal manufacturing tolerances. Minor design changes shall be permitted to be qualified through a reduced test program. Changes of design specified in table 6.7 shall require design qualification testing as specified in the table. Table 6.1. - Material design qualification test Relevant paragraph of this annex Steel Aluminium Resins Fibres Plastic liners Tensile properties 6.3.2.2. 6.3.3.4. 6.3.5. 6.3.6. Impact properties 6.3.2.3. Bending properties 6.3.2.4. Weld examination 6.3.2.5. Sulfide stress cracking resistance 6.3.2.6. Sustained load crack resistance 6.3.3.3. Stress corrosion cracking 6.3.3.2. Shear strength 6.3.4.2. Glass transition temperature 6.3.4.3. Softening/Melting temperature 6.3.6. Fracture mechanics*/ 6.7. 6.7. */ Not required if flawed cylinder test approach in paragraph A.7. of Appendix A is used. Table 6.2 - Impact test acceptable values Cylinder diameter D, mm > 140 ≤ 140 Direction of testing transverse longitudinal Width of test piece, mm 3 - 5 > 5 - 7.5 > 7.5 - 10 3 to 5 Test temperature, °C -50 -50 Mean of 3 specimens Impact strength, J/cm² Individual specimen 30 35 40 60 24 28 32 48 Table 6.3 - Minimum actual burst values and stress ratios CNG-1 All-metal CNG-2 Hoop-wrapped CNG-3 Fully-wrapped CNG-4 All-composite Burst pressure [MPa] Stress ratio [MPa] Burst pressure [MPa] Stress ratio [MPa] Burst pressure [MPa] Stress ratio [MPa] Burst pressure [MPa] All metal 45 Glass 2.75 50 1) 3.65 70 1) 3.65 73 Aramid 2.35 47 3.10 60 1) 3.1 62 Carbon 2.35 47 2.35 47 2.35 47 Hybrid 2) 2) 2) Note 1 - Minimum actual burst pressure. In addition, calculations must be performed in accordance with paragraph 6.5. of this annex to confirm that the minimum stress ratio requirements are also met. Note 2 - Stress ratios and burst pressures shall be calculated in accordance with paragraph 6.5. of this annex. Table 6.4 - Cylinder design qualification tests Test and annex reference Cylinder type CNG-1 CNG-2 CNG-3 CNG-4 A.12 Burst A.13 Ambient temp/cycle A.14 Acid environment test A.15 Bonfire A.16 Penetration A.17 Flaw tolerance A.18 High temp. creep A.19 Stress rupture A.20 Drop test A.21 Permeation A.24 PRD performance A.25 Boss torque test A.27 Natural gas cycling A.6 LBB assesment A.7 Extreme temperature/cycle X * X * X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X = required * = Not required for cylinders...
AutoNDA by SimpleDocs
Change of Design. A design change is any change in the selection of structural materials or dimensional change not attributable to normal manufacturing tolerances. Minor design changes shall be permitted to be qualified through a reduced test program. Changes of design specified in table 6.7 shall require design qualification testing as specified in the table. E/ECE/324 Rev.2/Add.109 Regulation No. 110 page 64 Annex 3 Table 6.1 - Material design qualification test Relevant paragraph of this annex Steel Aluminium Resins Fibres Plastic liners Tensile properties 6.3.2.2 6.3.3.4 6.3.5 6.3.6 Sulfide stress cracking resistance 6.3.2.4 Impact properties 6.3.2.3 Sustained load cracking resistance 6.3.3.3 Stress corrosion cracking 6.3.3.2 Shear strength 6.3.4.2 Glass transition temperature 6.3.4.3 Softening/Melting temperature 6.3.6 Fracture mechanics * 6.7 6.7 * Not required if use flawed cylinder test approach in paragraph A.7 (appendix A) Table 6.2 - Impact test acceptable values Cylinder diameter D, mm > 140 140 Direction of testing transverse longitudinal Width of test piece, mm 3 - 5 > 5 - 7.5 > 7.5 - 10 3 to 5 Test temperature, (C -50 -50 Mean of 3 specimens Impact strength, J/cm² Individual specimen 30 35 40 60 24 28 32 48 Table 6.3 - Minimum actual burst values and stress ratios CNG-1 All-metal CNG-2 Hoop-wrapped CNG-3 Fully-wrapped CNG-4 All-composite Burst pressure [MPa] Stress ratio [MPa] Burst pressure [MPa] Stress ratio [MPa] Burst pressure [MPa] Stress ratio [MPa] Burst pressure [MPa] All metal 450 Glass 2.75 50 1) 3.65 70 1) 3.65 73 Aramid 2.35 47 3.10 60 1) 3.1 62 Carbon 2.35 47 2.35 47 2.35 47 Hybrid 2) 2) 2) Note 1 - Minimum actual burst pressure. In addition, calculations must be performed in accordance with paragraph 6.5. of this annex to confirm that the minimum stress ratio requirements are also met. Note 2 - Stress ratios and burst pressures shall be calculated in accordance with paragraph 6.5. of this annex. E/ECE/324 Rev.2/Add.109 Regulation No. 110 page 65 Annex 3 Table 6.4 - Cylinder design qualification tests Test and annex reference Cylinder type CNG-1 CNG-2 CNG-3 CNG-4 A.12 Burst A.13 Ambient temp/cycle A.14 Acid environment test A.15 Bonfire A.16 Penetration A.17 Flaw tolerance A.18 High temp. creep A.19 Stress rupture A.20 Drop test A.21 Permeation A.24 PRD performance A.25 Boss torque test A.27 Natural gas cycling A.6 LBB assesment A.7 Extreme temperature/cycle X * X * X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X...
Change of Design. PIONEER shall be entitled to make any and all changes in details of design, construction or arrangement of the product as PIONEER in its sole discretion determines will constitute an improvement upon the product or any specifications or designs previously furnished to the Purchaser.
Change of Design. FRO expressly reserves the right to change or modify the design and construction of any of its equipment without obligation to notify AOL as long as the functionality of such changes and/or modifications meet or exceed the functionality of FRO’s published specifications.
Change of Design. Changed Item Required Tests Metallic container or liner material - Initial burst, Initial pressure cycle life - Sequential hydraulic tests - Fire test Plastic liner material - Initial pressure cycle life Changed Item Required Tests - Sequential hydraulic tests - Sequential pneumatic tests - Fire test Fiber material 1 - Initial burst, Initial pressure cycle life - Sequential hydraulic tests - Fire test Resin material - Initial burst, Initial pressure cycle life - Sequential hydraulic tests - Fire test Diameter 2 ≤20% - Initial burst, Initial pressure cycle life >20% - Initial burst, Initial pressure cycle life - Sequential hydraulic tests - Fire test Length ≤50% - Initial burst, Initial pressure cycle life - Fire test 3 >50% - Initial burst, Initial pressure cycle life - Sequential hydraulic tests - Fire test 3 Coating - Sequential hydraulic tests - Fire test 4 Boss 5 Material, geometry, opening size - Initial burst, Initial pressure cycle life Sealing (liner and/or valve interface) - Sequential pneumatic tests Fire protection system - Fire test Valve change 6 - Sequential pneumatic tests - Fire test 7 Notes:
Change of Design. LION may change the design or specifications of any of the LION Products at any time without notice and without obligation to make the same or any similar change upon any products previously purchased by or shipped to DEALER.
Change of Design. Manufacturer may, at any time and without liability to Distributor, improve, modify or discontinue any Product or feature of any Product. Manufacturer will not be obliged to make any change or upgrade to any Product shipped to Distributor prior to the official introduction of any change to same. Manufacturer may in writing, without liability to Distributor, fill any order placed by Distributor for any given Product by substituting therefore a modified or changed version of the same, so long as there is no significant loss of performance and/or functionality.
AutoNDA by SimpleDocs
Change of Design. Company reserves the right to change the design of Company Products or parts thereof at any time without notice to the Distributor. Company may, but shall not be obligated to, make similar changes on any Company Products or parts previously shipped to Distributor or to install or furnish any other different parts than were contained therein when shipment was made.
Change of Design. 9.1. If, during the performance hereunder, Party A requests modification of this Contract and the design scope and elements thereof, Party B shall satisfy such request to the extent possible, and may, when necessary, properly postpone the time of delivery of drawings.
Change of Design. Any change in scope, design, color, size, texture, material, or detail that significantly alters the approved design, or affects installation, scheduling, site preparation, or maintenance of the Artwork shall require review and written approval of the State. Prior to execution of any significant change, the following procedure shall be followed:
Draft better contracts in just 5 minutes Get the weekly Law Insider newsletter packed with expert videos, webinars, ebooks, and more!